milwaukee LM60 Heavy Duty Electric Tools Instructions
- June 6, 2024
- Milwaukee
Table of Contents
Heavy Duty Electric Tools
Instruction for use
Congratulations on the purchase of your Milwaukee LM 60.
**The safety instructions and the user manual should be read through
carefully before you use the product for the first time. The person
responsible for the product must ensure that all users understand these
directions and adhere to them.
Symbols used in this manual
The symbols used have the following meaning:
**WARNING Indicates a potentially hazardous situation or an unintended use
that, if not avoided, could result in death or serious injury.
****CAUTION: Indicates a potentially hazardous situation or an unintended use
which, if not avoided, may result in minor injury and/or in appreciable
material, financial and environmental damage.
Important paragraphs must be adhered to in practice, as they enable the
product to be used in a technically correct and efficient manner.
Intended Use
Permitted uses
- Measuring distances
- Computing functions, e.g. areas and volumes
Adverse uses
- Using the instrument without instructions
- Using outside the stated limits
- Deactivation of safety systems and removal of explanatory and hazard labels
- Opening of the equipment by using tools (screwdrivers etc.)
- Carrying out modification or conversion of the product
- Use of accessories from other manufacturers without the express approval of Milwaukee.
- Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines that are running, or near parts of machines or installations which are unprotected
- Aiming directly into the sun
- Deliberate dazzling of third parties; even in the dark
- Inadequate safeguards at the surveying site (e.g when measuring on roads, construction sites, etc.)
Limits of use
Also, see section “Technical data”.
The Milwaukee LM 60 is designed for use in areas permanently habitable by
humans, do not use the product in explosion hazardous areas or in aggressive
environments.
Responsibilities
Responsibilities of the manufacturer Milwaukee Electric Tool, D-71364
Winnenden, Germany:
Milwaukee is responsible for supplying the product, including the User Manual
and original accessories, in completely safe condition.
Responsibilities of the person in charge of the instrument:
WARNING The person responsible for the instrument must ensure that the
equipment is used in accordance with the instructions. This person is also
accountable for the deployment of personnel and for their training and for the
safety of the equipment when in use.The person in charge of the product has
the following duties:
- To understand the safety instructions on the product and the instructions in the user manual.
- To be familiar with local safety regulations relating to accident prevention.
- To inform Milwaukee immediately if the equipment becomes unsafe.
Overview
Keyboard
See drawing :A
- ON (ON/MEAS) – button
- PLUS [+] – button
- FUNCTION – button
- HISTORICAL MEMORY – button
- ILLUMINATION – button
- CLEAR/OFF – button
- TIMER/UNITS – button
- REFERENCE – button
- MINUS [-] – button
Display
See drawingB
- Laser “ON”
- Reference (front/rear/end piece)
- Pythagoras
- Timer (self-triggering)
- Historical memory
- Area/volume
- Battery status
- Units with exponents (2/3)
- Intermediate line 2
- Intermediate line 1
- Main targets
- min/max display
- Info symbol
Startup
Inserting / Replacing Batteries
-
Remove battery compartment lid.
See drawing .**C **
-
Insert batteries, observing correct polarity.
-
Close the battery compartment.
Replace the batteries when the symbol flashes permanently in the display
Only use alkaline batteries.
If the instrument will not be used for a long time, remove the batteries as a
protection against corrosion.
Operation
Measuring Conditions
Range
The range is limited to 60 m. At night or dusk and if the target is in shadow
the measuring range without a target plate is increased. Use a target plate to
increase the measurement range during daylight, or if the target has poor
reflection properties!
Target Surfaces
CAUTION: Measuring errors can occur when measuring toward colourless
liquids (e.g. water) or dust-free glass, Styrofoam or similar semi-permeable
surfaces. Aiming at high gloss surfaces may deflect the laser beam and lead to
measurement errors.
Hazards of Use
CAUTION: Watch out for erroneous distance measurements if the instrument
is defective or if it has been dropped or has been misused or modified.
Precautions: Carry out periodic test measurements. Particularly after the
instrument has been subject to abnormal use, and before, during and after
important measurements. Make sure the Milwaukee LM 60 optic is kept clean and
that there is no mechanical damage to the bumpers.
CAUTION: In using the instrument for distance measurements or for
positioning moving objects (e.g. cranes, building equipment, platforms, etc.)
unforeseen events may cause erroneous measurements.
Precautions:
Only use this product as a measuring sensor, not as a control device. Your
system must be configured and operated in such a way, that in case of an
erroneous measurement, malfunction of the device, or power failure due to
installed safety measures (e.g. safety limit switch), it is assured that no
damage will occur.
Switching on/off
1x briefly: the instrument and the laser are switched on.
The display shows the battery symbol until the next button is pressed.
Pressing this button for longer switches the instrument off.
The instrument switches off automatically after three minutes of inactivity.
Setting the instrument
Press long until the desired unit is displayed.
Possible units:
| Distance| Area| Volume
---|---|---|---
1.| 0.000 m| 0.000 m2| 0.000 m3
2.| 0’0″ 1/16| 0.00 ft2| 0.00 ft3
3.| 0 in 1/16| 0.00 ft2| 0.00 ft3
4.| 0.00 ft| 0.00 ft2| 0.00 ft3
CLEAR-Key
1x briefly: the last action is cancelled.
Illumination
**** 1x briefly: the display illumination is switched on or off.
Reference Setting
The default reference setting is from the rear of the instrument. The
instrument can be set for the following measurements:
- To measure from an edge (see drawing D ), fold-out the stop bracket until it snaps in for the first time. See drawing E .
- To measure out of a corner (see drawing D ), fold-out the stop bracket until it snaps in, pushes the stop bracket with a little force to the right side; the stop bracket can now be completely unfolded. See drawing E.
CAUTION: Make sure that when measuring from the unfolded endpiece, the
measuring reference is set to “End piece”!
1x briefly: the next measurement is taken from the front edge.
2x briefly: the measurement is taken from the unfolded end piece.
After one measurement, the reference returns automatically to the default
setting (rear reference).
1x long: the measurements are taken with the front as a reference until a new
measuring reference is set
2x long: the measurements are taken from the unfolded end piece until a new
measuring reference is set.
See drawing F .
Measuring
Single Distance Measurement
ON 1x briefly: the laser is activated.
ON 1x briefly: a distance measurement is taken.
The result is displayed immediately.
Continuous measurement
Distances can be measured with this function 1x long: a “beep” is sounded. A
continuous measurement is started.
ON 1x briefly: the continuous measurement is stopped.
ON The last measured value is displayed in the summary line.
Minimum-/Maximum-Measuring
This function enables determining the minimum or maximum distance from a
specific measuring point, e.g. the determination of room diagonals (maximum
value) or horizontal distance (minimum value).
Switching on continuous measurement (see above). The corresponding maximum and
minimum values are displayed.
Functions
Addition / Subtraction
Distance Measurement.
+ 1x briefly: the next measurement is added to the previous one.
– 1x briefly: the next measurement is subtracted from the previous one.
Repeat this procedure for as many times as required. The result is displayed
in the summary row, the previously measured value is displayed in intermediate
line 2, the value to be added in intermediate line 1.
1x briefly: the last step is cancelled.
Area function
F 1x briefly: The symbol is displayed.
ON 1x briefly: takes first distance measurement (e.g. length)
ON 1x briefly: takes second distance measurement (e.g. width)
The result of the area measurement is displayed in the summary row, the
individually measured values are displayed in intermediate lines 1 and 2.
Adding and subtracting areas
Calling up the area function and measuring areas.
Press **+or- **
ON 1x briefly: takes first distance measurement (e.g. length)
ON 1x briefly: takes second distance measurement (e.g. width)
The result of the second area measurement, “+” flashes.
ON 1x briefly: confirms the addition; the added area results are
displayed in the summary row.
Volume function
**F**
2x briefly: the symbol is displayed.
ON 1x briefly: takes first distance measurement (e.g. length)
ON 1x briefly: takes second distance measurement (e.g. width)
The result of the area measurement from the values already measured is
displayed in the summary row.
ON 1x briefly: takes the third distance measurement (e.g. height). The
value is displayed in intermediate line 1.
The result of the area measurement is displayed in the summary row, the two
previously measured values in intermediate lines 1 and 2.
Indirect Measurement
The instrument can measure distances with the Pythagorean method. This
procedure facilitates in measuring distances that are difficult to access.
Adhere to the prescribed sequence of measurements:
- All target points must be vertical or horizontal on the surface of the wall.
- The best results are achieved when the instrument is rotated around a fixed point (e.g. the stop bracket is fully extended and the instrument is placed against a wall).
- To take the measurement, the minimum/ maximum function can be called up. The minimum value is used for measurements that must be at right-angles to the target; the maximum distance is used for all other measurements.
Make sure that the first measurement and the distance to be measured are at
right angles. Use the minimum/maximum function.
Indirect measurement – determining a distance using 2 Auxilliary
measurements
See drawing **G**
F 3x briefly: the symbol is displayed.
The distance to be measured flashes in the symbol.
ON 1x briefly: takes a measurement of the distance
The second distance to be measured flashes in the symbol
ON 1x briefly: takes a measurement of the horizontal distance
The result of the function is displayed in the summary row.
If the ON button is pressed for a long time while measuring a distance,
maximum or minimum continuous measuring is activated.
Indirect measurement – determining a distance using 3 Auxilliary
measurements
See drawing H
F 4x briefly: the symbol is displayed.
The distance to be measured flashes in the symbol.
ON 1x briefly: takes a distance measurement
The second distance to be measured flashes in the symbol
ON 1x briefly: takes a horizontal measurement. The third distance to be
measured flashes in the symbol
ON 1x briefly: takes a measurement of the distance
The result of the function is displayed in the summary row.
If the ON button is pressed for a long time while measuring a distance,
maximum or minimum continuous measuring is activated.
Stakeout function
This function is helpful when staking out equal distances, e.g in the
erection of wooden substructures. See drawing I
F 5x briefly: the symbol ++ is displayed.
A value is displayed in the summary row (default value 1.000 m). This value
can be adjusted to the desired stakeout distance.
+ The value is increased.
– The value is reduced.
Holding the button down accelerates the speed at which the value changes.
ON 1x briefly: starts the continuous measurement.
In intermediate line 1, the set distance or the next appropriate multiple
thereof is displayed. In the summary row, the distance to the next appropriate
stake point is displayed.
When approaching a stakeout point (to less than 0,10 m), the instrument starts
to beep. When the point is reached, the beep sound changes and intermediate
line 1 starts to
flash.
1x briefly: distance measurement is interrupted and the instrument switches
back to individual distance measuring mode.
Historical memory
M± 1x briefly: the symbol and the last measured value are displayed.
Use the “+” or “-” buttons to navigate through the last 10 values. The values
can also be used in functions.
Using stored values in functions
Using added distances in area functions (e.g. wall surfaces or painters):
Adding distances (see additions/subtractions)
F Call up area function to e.g. measure the height of a room.
M± 1x briefly: calls up the historical memory and possibly search for the
correct value.
M± 1x long: the value is entered into the function and the result of the
function (e.g. area) is displayed.
Timer (self-triggering)
1x briefly: The symbol is displayed.
+ The timer is reset to 5 seconds. The value is increased.
– The value is reduced.
Holding the buttons down increases the rate of change of the values. The
countdown starts automatically (if the laser is activated) and then triggers
the measurement.
Switching off the beep
M± Press and hold simultaneously for 5 seconds:
The beep is switched off. To reactivate it, press and hold for 5 seconds.
Appendix
Display Notices
All display notices are either displayed with or “Error”. The following errors
can be corrected.
| Cause| Correction
---|---|---
204| Calculation error| Repeat procedure
252| Temperature too high| Let the device cool down.
253| Temperature too low| Warm device up
255| Received signal too weak, time for a measurement too long.| Use a target
plate
256| Received signal too strong| Use target plate (grey side)
257| Faulty measurement, too much background light| Use target plate (brown
side)
258| Outside of the range of measurement| Select measurement distance within
the range of measurement
Error| Cause| Correction
Error| Hardware error| Should this message remain active after switching the
instrument off and on several times, please contact the dealership.
Technical Specifications
Range | 0.05 m to 60 m* |
---|---|
Measuring accuracy (2 a) | typically ± 1.5 mm** |
Smallest unit displayed | 1 mm |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection against splashes and dust | IP 54, dust-proof, splash-proof |
Autom. power off: Laser Instrument | after 60 s after 180 s |
Illumination | √ |
Folding out endpiece | √ |
Battery life,
Type 2 x AAA/Micro| up to 5 000 measurements
Dimension| 114 x 51 x 27mm
---|---
Weight| 120 g
Temperature range: Storage Operation| -25°C to +70°C 0°C to +40°C
- Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties!
in favourable conditions (good target surface properties, room temperature) up to 10 m. In unfavourable conditions, such as intense sunshine, poorly reflecting target surface or high-temperature variations, the deviation over distances above 10 m can increase by ± 0.15 mm/m.
Electromagnetic Compatibility (EMC)
The term “electromagnetic compatibility” is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present, and without causing electromagnetic interference to other equipment.
WARNING The Milwaukee LM 60 conforms to the most stringent requirements of the relevant standards and regulations.
Yet. the possibility of the product causing interference in other equipment cannot be fully excluded.
Laser classification
The Milwaukee LM 60 produces a visible laser beam that emerges from the front of the instrument. See drawing K.
The product is a Class 2 Laser Product in accordance with:
IEC60825-1: 2007 “Radiation safety of laser products”
Class 2 Laser Products:
Do not stare into the beam or direct it unnecessarily at other persons. Eye protection is normally afforded by aversion responses including the blink reflex.
WARNING Looking directly into the laser beam with optical aids (e.g. binoculars, telescopes) can be hazardous.
Precautions: Do not look directly into the beam with optical aids.
CAUTION: Looking into the laser beam may be hazardous to the eyes.
Precautions: Do not stare into the beam. Do not look into the laser beam. Make sure the laser is aimed above or below eye level (particularly with fixed installations, in machines, etc.).
Labelling**
For the position of the type, plate sees drawing.
Care
Wipe off dirt with a damp, soft cloth. Do not immerse the instrument in water.
Do not use aggressive cleaning agents or solutions.
Disposal
CAUTION: Flat batteries must not be disposed of with household waste.
Care for the environment and take them to the collection points provided in
accordance with national or local regulations.
The product must not be disposed of with household waste. Dispose of the
product appropriately in accordance with the national regulations in force in
your country. Adhere to the national and country-specific regulations.
All right reserved for changes (drawings, descriptions and technical
specifications).
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>