BS CHARGER BS30 Smart Battery Charger and Maintainer User Manual
- June 9, 2024
- BS CHARGER
Table of Contents
- BS CHARGER BS30 Smart Battery Charger and Maintainer
- Instruction
- MAIN FEATURES
- PROTECTION FEATURES
- BATTERY TYPES & CAPACITY
- ELECTRICAL PARTS
- ENVIRONMENTAL CHARACTERISTICS
- TECHNICAL SPECIFICATIONS
- OPERATING INSTRUCTIONS
- THE CHARGING PROCESS
- CHARGE CURVE
- LED STATUS INIDICATOR TABLE
- TROUBLE SHOOTING
- MAINTENANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BS CHARGER BS30 Smart Battery Charger and Maintainer
Instruction
THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR BATTERY
CHARGER & MAINTAINER: BS 30
Lithium (LiFePO4) & Lead Acid compatible
IMPORTANT SAFETY INSTRUCTIONS
Please read this manual and follow the instructions carefully before using the
charger.
WARNING
- The battery charger is designed to charge 12V Lead Acid batteries (LA) or Lithium (LiFePO4) (LFP) battery from 4Ah to 60Ah and maintain batteries up to 120Ah.
- We always recommend that you check the Battery Manufacturers specifications before using this charger.
- Explosive gases may escape from the battery during charging. Provide ventilation to prevent flames and sparks.
- For indoor use. Do not expose charger to rain, snow or liquids.
- Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes.
- Never charge a frozen battery.
- Never charge a damaged battery.
- Never place the charger on the battery while charging.
- Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
- When working with a Lead Acid battery, remove personal metal items such as rings, bracelets, necklaces, watches…
- NEVER smoke or allow a spark or flame in vicinity of battery or engine.
- Do not charge non-rechargeable batteries.
- In order to reduce risk of electric shock, unplug charger from AC outlet before doing any.
- maintenance or cleaning. Turn off controls will reduce risk.
- The kit is not supposed to be used by children or by people who are not able to understand the manual, unless they are supervised by a responsible person who ensures the proper use of the kit.
MAIN FEATURES
- Auto Detect – Auto-detect for Lead acid or LiFePO4 battery hooked.
- Adaptable charging algorithm – Enable the precise charging algorithm targeted for Lead acid or LiFePO4 batteries.
- Smart re-activation – Allows it to wake up “dead” LiFePO4 batteries where the BMS under-voltage protection has been triggered.
- Battery qualification detection – Automatically detect the battery initial voltage.
- Low voltage Start – Activate the heavy discharged low-voltage battery.
- Battery bad cell detection – Smart detection to the battery bad cells and error indication.
- Weak or sulphated Battery detection – Automatically detect the weak or heavy-sulphated battery and error indication.
- Charging time management – Multiple charging stages and charging time management.
- Pulse maintenance – Long term pulse mode maintenance to keep the Lead acid battery at optimal performance.
- Flexible output cable – Detachable clamps terminal cord sets with SEA connector.
- Flexible hook – Built with a hook for hanging up the unit in special locations.
PROTECTION FEATURES
- Connection spark free.
- Never overcharge your battery.
- Output short circuit or reverse polarity protection.
- Charging timer for each charge phase protection.
- Thermal run-away protection at the battery side.
- Internal over-heat protection.
- Conformal coatings prevent from moisture for the inside circuit board.
- Corrosion-resistant output connectors.
BATTERY TYPES & CAPACITY
- Suits all Lead Acid type batteries (Conventional, AGM & Gel).
- Suits for lithium (LiFePO4) battery.
- Battery capacity:
Charge rate| Battery capacity – charging| Battery capacity – maintaining
---|---|---
3Amp| 4-60Ah| 4-120Ah
ELECTRICAL PARTS
Delivered with:
- Input Cord: 183cm input leads with VDE plug.
- Output Cord: 122cm with quick connector.
- Extend Cord: 61cm with battery ring terminal / battery clips.
ENVIRONMENTAL CHARACTERISTICS
- Operating temperature: 0 to 40° C.
- Storage temperature: -25 to 85°C.
- Operating humidity range: 0 to 90% RH.
- Cooling: natural cooling.
TECHNICAL SPECIFICATIONS
AC input | 90~265Vac |
---|---|
Input Frequency | 50/60Hz |
Rated output | 12V 3Amp |
Suit for battery type | Compatible for Lead Acid or Lithium (LiFePO4) battery |
Power Efficiency | >80% |
Charging stage | Multiple – 9 stages |
Start voltage | 2V |
Charging voltage | 14.4V |
Float voltage – Lead acid battery | 13.6V |
Maintenance voltage – Lead acid battery | 13.0 – 13.8V |
IP class | IP22 |
OPERATING INSTRUCTIONS
STEP 1 – Pre-Charge Check & Electrolyte Level Check
- Check the Battery Electrolyte level for Lead Acid battery (not required on sealed & maintenance free batteries). If necessary, remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines.
STEP 2 – Connecting the Battery Charger to your Battery
- Connect the Red lead from the charger to the positive (+) battery terminal.
- Connect the Black lead from the charger to the negative (-) battery terminal.
STEP 3 – Connect the Battery Charger to Mains Power
- Connect the battery charger to a Mains Powered socket.
- Turn on the Mains Power.
Once the connection instructions have been followed, AC power is presented,
power White LED ON. The charger will begin charging automatically, the
“Charging” Blue LED is ON. When full charge is reached, the “Maintaining”
“Full” Green LED will be ON. The Main-taining Float Mode allows the charger to
effectively be left connected to your batteries, over the course of a season
for Lead acid batteries, without overcharging your batteries and maintains
your battery’s full charge, for a LiFePo4 battery, it will automatically
terminate the charge if the battery fully charged and Green LED will be ON.
STEP 4 – Disconnecting the Battery Charger from Battery
The AC Power Socket from the outlet; Remove the Black lead and then the Red
lead. Check electrolyte levels if possible. (As they may need topping up with
distilled water after charging).
THE CHARGING PROCESS
The battery charger provides the multiple charging phases subjected to the
Lead acid battery sensed or LiFePO4 battery sensed.
Smart re-activation
The battery charger will wake up the “dead” LiFePO4 battery where the under-
voltage protection has been triggered.
-
Soft start
In this phase rising voltage and a maximum of 50% of bulk phase current is applied to the battery to start the charging cycle. -
Bulk stage
In this phase rising voltage and maximum output current is applied to the battery. -
Analysis-1 Stage
In this phase the battery charger tests the battery in order to detect bad cells (only for Lead acid batteries). For abnormal cell de-tection results please refer to the troubleshooting section. -
Absorption stage
In this phase a constant voltage and tapering current is applied to the battery to ensure it reaches 85% state of charge. -
Analysis- 2 Stage
In this phase the charger tests the battery again in order to detect bad cells and high levels of sulphation (only for Lead acid batteries). -
Float and Maintenance
Compatible only with Lead Acid batteries this stage is used for long term battery maintenance. -
Float returns to Bulk charging
When battery voltage is dropped below 12.5v. -
Lithium (LiFePo4) Recharge phase
If the battery voltage falls below 12.8V; the battery charger will automatically return to Bulk phase.
CHARGE CURVE
- No float & maintenance stages for Lithium. Once the battery is fully charged, the charge is stopped.
LED STATUS INIDICATOR TABLE
NORMAL INDICATION
AC Power presented | WHITE LED ON |
---|---|
In soft start phase | BLUE Charging light FLASH |
In charging phase | BLUE Charging light ON |
In Float mode or Maintenance | GREEN LED ON |
ABNORMAL INDICATION
Output reverse polarity or shorted | RED Fault LED ON |
---|---|
Charging timer timed out | RED Fault LED ON |
Battery slight sulphated | GREEN Fault LED FLASH |
Battery heavily sulphated or cells shorted | RED Fault LED FLASH |
TROUBLE SHOOTING
Types of Problems| Indication| Possible Causes| Suggested
Solution
---|---|---|---
Charger does not work?| No Indicator lights on.| – No AC power.| Check AC
connections and make sure Power Point is switched ON.
Charger has no DC output?| Fault LED is On.| ****
- Output is short circuited
- Reverse polarity connection to Battery.
|
- Check DC connection between charger and battery and make sure they are not short circuiting.
- Check that the crocodile clips haven’t fallen off the battery.
- Check that the crocodile clips / ring terminals are connected to the correct polarity.
Long charging time, Full light does not come on?| Fault LED is ON.|
- Battery capacity too large
- Battery is defective.
| Check the charger specification matches the battery capacity.
Long charging time, Full light does not come on?| Fault LED is Flash.|
Battery cells internal shorted, battery heavily sulphated.| Battery cannot be
charged and must be re- placed.
MAINTENANCE
The battery charger is maintenance free. If the power cord is damaged, the charger must be left to the reseller for maintenance. The case should be cleaned occasionally. The battery charger should be disconnected from the power while cleaning.
SMART BATTERY CHARGER 12V – 1/4/6A & MAINTAINER WITH RECONDITIONING
FUNCTION
For Lead Acid
- Smart battery charger & maintainer with reconditioning function
- Safe: connection spark free, reverse polarity, short circuit and internal overheat protection
- Easy to use: connect & forget
- Battery thermal runaway protection
- Ideal for charging during winter season
SMART BATTERY CHARGER 12V – 1.5A & MAINTAINER WITH RECONDITIONING
FUNCTION
For Lead Acid
- Smart battery charger & maintainer with reconditioning function
- Ideal for charging during winter season
- Safe: connection spark free, reverse polarity, short circuit and internal overheat protection
- Easy to use: connect & forget
- Multiaxis hook
SMART BATTERY CHARGER 6V/12V – 1A & MAINTAINER
For Lead Acid & Lithium
- Smart battery charger & maintainer
- Auto detect Lead Acid or Lithium technology
- Adaptable charging algorithm for Lead Acid & Lithium (LiFePO4)
- Safe: connection spark free, reverse polarity, short circuit and internal overheat protection
- Easy to use: connect & forget
- 6V & 12V manual switch selection
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>