GOLD NOTE TUBE-1012 Valves Tube Output Stage User Manual

June 6, 2024
GOLD NOTE

GOLD NOTE - icon TUBE-1012 /1006 Valves Tube Output Stage
User Manual
GOLD NOTE TUBE 1012 Valves Tube Output
Stage

PACKAGE CONTENT

  • GOLD NOTE TUBE-1012/1006
  • 1x AC power cord
  • 1x GN TUBE connection cable (1.5 m)
  • User manual

TECHNICAL SPECIFICATIONS

Max Input Level: ( THD <1% ) 12 Vrms on XLR, 6 Vrms on RCA
Max Output Level: ( THD <1% ) 16 V on XLR, 8 V on RCA
THD+N 0.0028% @ 1kHz – 1.736V
S/N >100dB @ 1kHz – 1.736V
Recommended load: >10KΩ
Output Impedance: <600Ω
Gain: 2dB

INPUTS TUBE
1x XLR Line In
1x RCA Line In
1x Tube In (5-pole XLR for Gold Note sources only)

POWER
100-120V or 220-240V, 50/60Hz
Power consumption: TUBE-1012 80W
Power consumption: TUBE-1006 50W
TUBE-1006: 2x Gold Note custom made transformer
TUBE-1012: 3x Gold Note custom made transformer Super
Linear Vacuum Tube Regulator with 4 Inductive Choke filters
Fuse 220/240V 2A F/T
Fuse 100/120V 3,15A F/T

DIMENSIONS AND WEIGHT
Dimensions: 430 W x 135 H x 370 D mm
Weight: TUBE-1012 16Kg net. – 21Kg boxed
Weight: TUBE-1006 13,3 Kg net. – 19 Kg boxed

INPUT OUTPUT INPUT VALUE OUTPUT VALUE
XLR 3P / TUBE GN XLR 3P / TUBE GN 1V 1.25V
XLR 3P / TUBE GN RCA 1V 0.625V
RCA RCA 1V 1.25V
RCA XLR 3P / TUBE GN 1V 2.5V

VALVES AND JUMPER

A large variety of valves can be installed on both the TUBE-1012 and TUBE-1006, allowing for greater versatility.
You can refer to the table below to check the jumper layout for the compatible model of valves.
Please refer to your dealer to install the valves into your TUBE Output Stage to avoid a breach of warranty.

PCB8003-B|

TYPE OF VALVE

|

JUMPER

---|---|---

E88CC
6N6P
6N1
6922
6H30P
6H6N

|

W1 pin 1,2
W2 pin 1,2
W3 pin 1,2
W4 pin 1,2

E83CC
E82CC
E81CC
12AX7
12AU7
12AT7

|

W1 pin 2,3
W2 pin 2,3
W3 pin 2,3
W4 pin 2,3

6N2P

|

W1 pin 1,2
W2 pin 1,2

PCB8003-B|

6N6P
6H30P
6H6N
6N1P

|

J3 pin 2,3
J4 pin 1,2
J5 pin 2,3
J6 pin 1,2

E82CC
12AU7

|

J3 pin 1,2
J4 pin 2,3
J5 pin 1,2
J6 pin 2,3

FRONT AND REAR PANELS

GOLD NOTE TUBE 1012 Valves Tube Output Stage - FRONT AND REAR
PANELS

  1. Power LED (blue or green depending on input selection)
  2. Power ON/OFF
  3. IN (input selection)

GOLD NOTE TUBE 1012 Valves Tube Output Stage - FRONT AND REAR PANELS
2

LINE OUTPUTS

  1. XLR balanced audio output

  2. RCA unbalanced audio output
    TUBE INPUT

  3.  GN TUBE input (5 pole connector for Gold Note units)
    LINE INPUTS

  4.  XLR balanced audio input

  5. RCA unbalanced audio input
    GN LINK

  6. OUT / IN to synchronize the unit with other Gold Note units in MASTER/SLAVE mode
    POWER

  7. Master Switch
    AC POWER PLUG

  8. AC Power plug with IEC fuse (2A)

USING TUBE-1012 AND TUBE-1006

With 6 or 12 tubes, our Valve Output Stage is the best way to enhance your system for improved realism and musicality. Our proprietary Totem-Pole Output Stage design, with six independent audio stages per tube, guarantees ultra- wide bandwidth response and ultra-low distortion to deliver the purest audio signal ever.
Thanks to new audio inputs on the rear panel our valve output stages can be connected with up to two sources at the same time using the TUBE INPUT for the Gold Note sources and the LINE INPUT for other manufacturers. The input can be easily selected from the front panel for maximum convenience and ease of use.

USING TUBE-1012 AND TUBE-1006 WITH GOLD NOTE UNITS

  1. Connect the TUBE-1012/TUBE-1006 to the power outlet using the AC power cord included. The AC power socket is located
    on the rear panel of the unit.

  2. Connect the TUBE-1012/TUBE-1006 to your Gold Note unit using the GN TUBE connection cable included. Please ensure to
    use the TUBE INPUT connectors located on the rear panel.

  3. If you want the TUBE-1012/TUBE-1006 to automatically turn ON/OFF along your other Gold Note unit in master/slave mode, connect your other Gold Note unit (master) to the TUBE-1012/TUBE-1006 (slave) through the GN LINK IN connector found on the rear panel. If you want the TUBE-1012/TUBE-1006 to act as the master and control other Gold Note units, use the GN LINK OUT connector instead.

  4. Turn to ON the MASTER SWITCH of the TUBE-1012/TUBE-1006.

  5. The TUBE-1012/TUBE-1006 will turn ON/OFF as it is now controlled by the other Gold Note unit. When ON, the Power Led is blue as the TUBE INPUT is selected.

USING TUBE-1012 AND TUBE-1006 WITH OTHER UNITS

  1. Connect the TUBE-1012/TUBE-1006 to the power outlet using the AC power cord included. The AC power socket is located on the rear panel of the unit.
  2. Connect the TUBE-1012/TUBE-1006 to your other units using the LINE INPUT connectors located on the rear panel.
  3. Turn to ON the MASTER SWITCH of the TUBE-1012/TUBE-1006.
  4. Press the Power On button and then press once the IN button located on the front panel to select the LINE INPUT as the input – the Power Led will change from blue to green.
  5. Wait for approx. 30 seconds for the TUBE-1012/TUBE-1006 to reach the ideal operative temperature.

WARRANTY

PRODUCT REGISTRATION
We recommend registering the unit on our internet website within 15 days from the purchase at www.goldnote.it/product-registration If the unit is not registered correctly or has been purchased from a different country of the purchaser’s home address the unit will not be covered by any warranty and the registration will be refused.
Please note that the warranty does not cover in any case: Tubes, Phono Cartridge Stylus, and Batteries.
WARRANTY
All Gold Note products come with a warranty against defective materials and workmanship.
Any service and inspection must be carried out by a Gold Note dealer or distributor so in case you need any assistance with this product, please contact the seller.
If you experience any problems locating your official Gold Note dealer or distributor, please check our website.
PLEASE NOTE
Descriptions and technical characteristics may vary at any time and without notice.
WARNING
Gold Note products should only be opened, serviced, and inspected by certified Gold Note technicians and dealers.
Work performed by unqualified personnel may cause serious damage or personal injury. Opening of the product by non-authorized personnel will void the guarantee. In this case, contact your dealer to be advised on how the fault can be solved.
Do not return any object directly to the factory or to the distributor without being authorized to do so.

TROUBLESHOOTING

FAQ

ACTION DESCRIPTION HOW TO ADJUST IT
CLEANING THE UNIT The Unit is dirty and needs to be cleaned • With EXTREME

care use ONLY diluted alcohol and a very soft 100% cotton cloth to sweep dust and stains out.
• Any acid or not extremely soft cloth will irreversibly damage the amplifier’s fine aesthetic.
• Do not use any alcohol to clean the unit anodized label or printed parts. Only dry clothes are allowed.

TROUBLESHOOTING

SYMPTOM DESCRIPTION CAUSE REMEDY
TUBE-1012/1006 NOT WORKING LED is OFF The unit is not connected to the
power •Check the power cable and make sure it is connected properly

•Check the Master switch and make sure it is On
•Press the Power On/Standby button
The fuse is blown| Substitute the fuse with one of the same value
TUBE-1012/1006 NOT PLAYING| LED is ON| The unit is heating| Wait for the unit to be ready- about 30 sec

For spare parts visit the official Gold Note store at: www.akamaiaudio.it/

IMPORTANT SAFETY INFORMATION

GOLD NOTE TUBE 1012 Valves Tube Output Stage - icon CAUTION!
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER ONLY TO QUALIFIED GOLD NOTE SERVICE PERSONNEL FOR SERVICE

GOLD NOTE TUBE 1012 Valves Tube Output Stage - icon
2WARNING!
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE

Do not disassemble any part of the product.
Do not use any part of the product for other purposes.
For service and problems of any kind, contact qualified Gold Note personnel.
Protect the product from rain, humidity and keep away from heat sources, electric and electronic motors, etc.
The power Chord supplied must be used only on this unit.
Gold Note does not have responsibility for any improper use of this unit.

This appliance has a serial number located on the rear panel.
Please record the model and serial number and retain them for your records.
Serial Number:__
Model:_____

IMPORTANT SAFETY INFORMATION

  1. Read these instructions and store them.

  2. Heed all warnings.

  3. Follow the instructions.

  4. Do not use this apparatus near water.

  5. Clean only with a dry cloth.

  6. Do not block the ventilation openings and install them in accordance with the manufacturer’s instructions.

  7. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

  8. Do not defeat the safety purpose of the polarised or grounding-type plug: a polarised plug has two blades with one wider than the other.
    A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.
    If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.

  9. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

  10. Only use attachments/accessories specified by the manufacturer.

  11. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

  12. Unplug this apparatus during lightning storms or when unused for long periods of time.

  13. Refer all servicing to qualified service personnel only. Servicing is required when the apparatus has been damaged in any way (such as when the power cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture) and in any case when the apparatus does not operate normally or has been dropped.

NOTE

GOLD NOTE TUBE 1012 Valves Tube Output Stage - icon 3

Akamai S.r.l.
[email protected]
www.goldnote.it

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals