Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body Detection Instruction Manual

June 6, 2024
Universal Ubiquitous

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body Detection

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body Detection-
product

Dear customer,
Thank you for using our product. For better use, please carefully read this instruction. If you have any issues not mentioned here, please contact the provider. All parts of this booklet are reserved by our company, including words, pictures and graphics. Without written permission, no unit or individual shall extract, copy, translate or edit the content in this instruction.

Parts list

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-1

Dimensional Drawing

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-2

Platform/Software Operating Instruction

The software carried by the product divides into 2 versions: GS (WO platform, provides the secondary development) and LAN (LAN Client System, provides the secondary development). Please mark the need for software version when place the order. Please contact the customer service for another version if required. For more detailed platform/software instruction manual, please login into the official website to download or contact the customer services

Appearance description

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-3

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-4

Illumination intensity

The recognized face, of which, the illumination intensity( “intensity” in short) shall not be lower than 30 Lux/ The device has filling light itself. so when the device put in a totally dark environment,
the face illumination intensity, 0.5m distance to the device, is about 100 Lux. The nearer to the device, the higher the intensity is. If there is overexposure on the face, the face characteristics will be unable to be extracted and may lead to hard recognition.

Intensity test
The test standard is as shown on the picture: the angle between dotted line A and dotted line B is 90 ° , the test adopts the common light meter with full spectrum, and applies U30 standard light source, adjust the distance between source light and test object, subject to the illumination intensity of the object face at this time.

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-5

Reference to intensity

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-6

Illumination intensity in actual scenarios
Light issues may lead to big differences between site image and registered image; backlight, side-light and strong light will influence the recognition experience. (Analysis: from the view of human eyes, the color changes on face skin may result in wrong recognition of identity; unclear exposure area, no matter large or small, may result the identity judgement).

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-7
Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-8

Improvements

  1. Install the device in a place with little impact from light source.
  2. Add a registered image according to the site condition, and it is suggested to use this product to enroll images.
  3. Properly lower the threshold value according to usage.

Position

Device shall be installed in places avoiding backlight, side-light and strong light.
Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-9

Sunlight shines indoor
When the sunlight shines indoor through the window, the face recognition terminal device shall not be installed in shown black shadow area, instead, shall be installed in place with little sunlight impact, no side-light and no backlight. (Glass window can be deemed as no walls)

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-10

Glass window
If the room has glass wall, there is no shield for sunlight, then it is suggested to hang curtains over the window, and install the device in place with shield to avoid direct sunlight influencing the recognition. (Glass window can be deemed as no walls

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-11

Sunlight shines through the door, with glass window at one side
Sunlight shines through the door, the device shall be installed at the place with shields and little light impact. Glass window can be deemed as no shields, the device shall be installed at the side without glass window or with curtain hung.

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-12

Sunlight shines through the door
Sunlight shines through the door, the device shall be installed at the place with shields and little light impact.

Height

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-14

Suggested installation height (distance between the screen and the ground) is 1.4m, as the recognizable body height range, 0.5m distance away from the device, is 1.3m-1.7m; the recognizable body height range, 1m distance away from the device, is 1m-2m. (There are some deviations)

Steps

  1. Paste the installation sticker horizontally on the wall. According to the on-site position, choose suitable place for drilling. For narrow edge, choose upper and lower installation.
    Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-15

  2. Move the bracket, align holes on the bracket and on the wall. Thread tail lines out of the hole, and use self-tapping screw fix the bracket on the wall.
    Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-16

  3. Connect the tail lines with the host, move the device to up-down align the bracket slot. Use screws to fix the device and bracket.

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-17

Wiring connection

Wiring for magnetic door

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-18

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-19

Wiring for automatic door

Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-20 Universal
Ubiquitous OS-A6CC Uface 5 Lite Live Body Detection-21

Installation Notes

  1. When arrange the wires, if the 12V power supply cable of the host does not adopt the “Special power strip” and is in long distance, resulting in large resistance, then abnormal phenomena may occur easily such as insufficient voltage (11V), repeat restart, system crash and so on. Wiring connection of voltage metering is shown as follow
    Universal Ubiquitous OS-A6CC Uface 5 Lite Live Body
Detection-22

  2. The power adapter is put together with the device which is optional, such as EU standard, American standard, UK standard, and so on.

  • Extension of power cable (weak current) cannot exceed 2m, otherwise, it may cause insufficient power supply for the host end, and abnormal phenomena like repeat restart, system crash may If the power is far away from the device, the power cable can be extended (strong current).

  • If use other power adapter, 9V 1A as an example, then insufficient voltage and too weak current may cause repeat restart.

  • The cable cannot be too fine (such as network cable and fine line), it is suggested to connect multi-strand cable in parallel or use copper core bold cable, to ensure voltage >11V.
    Attention: If use network cable, the extension cable use 4-strand cable as positive pole and 4-strand cable as negative pole.

  • If not clear with how to extend, please contact the provider to change “Special power strip”.

Features

  • Characteristics
    Night infrared and RGB dual-filling light; completely resolve image frauds in all kinds of carriers with dynamic dual-camera anti-forg- ery; face database is 10000, the 1:N recognition accuracy is 99.99% under 0.1% false accept rate.

  • Store records in local

    • Device using cloud platform supports storing 3 thousand pieces of face images (smaller than 400KB), 50-thousand pieces of recognition records (0.45KB) and about 15-thousand pieces of site capture images;
    • Device using LAN support storing 3-thousand pieces of face images (each image by 100KB) and 50-thousand pieces of recognition records (including the latest 15-thousand pieces of site capture images)
  • Quick recognition speed
    Face detection takes around 120ms, (b) Face feature extraction takes around 150ms, (c) Face comparison takes 10ms (with 100,000 face database, take the average value after multiple comparison).

  • Secondary development (integrated)
    Supports interface in HTTP method; supports 232 serial-port output, as well as Wiegand 26 and 34 output, custom the configuration of output content.

  • Complete functions
    Supports recognition distance configuration; supports stranger detection; supports saving the site images of face recognition and stranger detection.

  • High extensibility
    Supports deployment methods like public network and LAN; supports screen display content configuration;built-in card reader access

FAQ

  • Try to restart and reset
    When the device stops in some interface for a long time, users can plug out the power switch, power-on reset and then restart. If it does not take effect, then can long press RESET button for 8-12s to restart the device. Besides, users can contact our staff and make some feedback.

  • Dustproof & Waterproof
    IP54, can prevent dust from invading the device and water from all directions.

  • Drop resistance
    Please avoid operations such as falling, breaking, bending, heavily pressing and so on.

  • Cleaning
    Please use soft cloth or such materials, lightly wipe the display screen or panel, and to avoid scrubbing with water and cleaner.

  • Low-temperature environment
    The normal working temperature for this device is -10 ~60 , if the actual temperature exceeds this range, that may influence the normal use of the device

Warranty description

Dear customer,
Thank you for purchasing and using this product. To better guarantee your satisfaction, please carefully read this warranty clauses after purchase.

  1. Warranty service
    If the device, following the user manual and operating instruction, still breaks down, contact after-sales staff at once, as they will judge the causes on basis of customer description and give remote guidance; if the guidance does not work, then the customer can send back the device for maintenance and test; if the device is unable to be sent back, contact after-sales staff in advance and ask them to head for the site to do the field maintenance. However, if the device problems found are not resulted by hardware or software system of our company after the field maintenance, then customer shall pay the extra fee incurred by the onsite service.

  2. Instruction
    There is a piece of product booklet inside the device package, and customer can contact after-sales staff and ask for installation guidance.

  3. Warranty period
    All products carry a 1-year guarantee period since the delivery date.

  4. Warranty scope
    Device breakdown caused by following conditions is not included within the warranty scope:

  • Any damages caused by incorrect use, maintenance or storage, as not follow the user manual;
  • Damages caused by falling, water intaking, improper storage or any other man-mad malicious damages;
  • Malfunction caused by force majeure such as natural disasters and external causes such as abnormal voltage;
  • Damages caused by shipment, please contact the department of transportation;
  • Malfunction or damages caused by unfavorable operating environment, such as too high or too low tempera- ture, poor condition, abnormal power system and so on;
  • Parts (power adapter, cables, screws) are not within the warranty If parts are lost or damaged, please contact our staff to purchase.
  1. Maintenance period
    When receive the product to be repaired, after-sales staff shall complete the maintenance and send it back within 5 working days. Further communication can be carried out if there are special circumstances.

  2. Supplemental instruction

  • Product damages, caused by natural disasters, external factors or improper operations, are not included within warranty Our company will make the final judgement of whether the damage is caused by above mentioned terms. Users open the product secretly without permission, and cause certain damage, which is also not included within replacement or warranty scope.
  • If the device expires the warranty period or not meets the warranty conditions, users may pay for the maintenance cost and shipping If the device is sent back without communication, it will not be maintained or repaired normally or will not be refunded, damages caused by this issue will not be compensated

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • onnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body