EPEVER RTU 2G A GPRS Transmission Terminal Instruction Manual

June 6, 2024
EPEVER

EPEVER logo

EPEVER RTU 2G A GPRS Transmission Terminal

EPEVER RTU 2G A GPRS Transmission Terminal

Thanks for selecting the EPEVER RTU 2G A solar wireless collector. Please read this manual carefully before using the product.
Please keep this manual for future reference.

Important Safety Instructions

  • Read the instructions and warnings in the manual carefully before installation.
  • The product should be situated away from the rain, exposure, dust, vibration, corrosion, and intense electromagnetic environment.
  • Please avoid water and other liquids enter into the product.
  • Never use the product at sites where electrostatic could occur, and avoid the antenna close to a metal object.
  • DO NOT disassemble or attempt to repair the product.
  • Power supply: DC 9~60V or 5V, it can be customized according to customers’ requirements.
  • Enable GPRS service for the SIM card before installation.

Overview

EPEVER RTU 2G A is a new wireless data transmission terminal based on the GPRS network. With the GSM/GPRS SIM card, the connected devices can easily access the EPEVER cloud server to realize remote, wireless, and networked communication. EPEVER RTU 2G A is suitable for EPEVER solar controller, inverter, and inverter/charger.

Features:

  • Extensive network coverage and flexible networking
  • Low operating costs (charged by network flow)
  • Adopt a non-standard DB9 male terminal
  • Embedded in Modbus RTU protocol
  • Automatic restore after disconnection
  • Support RS485 communication

Appearance

Sync. Indicator (LED1)| ****

Green

| ****

Slowly flashing (5s)

| Registered GPRS network successfully
---|---|---|---
Power indicator (LED2)| ****

Green

| Turn off after a flashing| ****

Correct power supply

Antenna port

EPEVER RTU 2G A GPRS Transmission Terminal fig1

The pin definition of the terminal(DB9 female) connected to the DB9 male terminal❸ is as follows.

EPEVER RTU 2G A GPRS Transmission Terminal fig2

Item Terminal Definition
1/2 NC Floating
3 VCC2 Power2 (12V/200mA)
4 GND2 Power GND2
5 GND1 Power GND1
6 NC Floating
7 RS485-A RS485-A
8 RS485-B RS485-B
9 VCC1 Power1 (5V/400mA)

Indicators
You can observe the indicators’ color and status through the hole❷.

Name Color Status Instruction

Network indicator (LED2)

|

Red

|

On solid

| Correct power supply
Unregistered GPRS network

Slowly flashing (5s)

| Registered GPRS network successfully

Parameter Configuration

  • Step1: Connect the DB9 terminal ❸ to the PC through a DB9 to USB adapter.
    Note: Conne ct an extern al power adapter to the DB9 female terminal to supply the EPEVER RTU 2G A.

  • Step2: Insert the SIM card and power on the EPEVER RTU 2G A. For detailed SIM card installation, refer to chapter 6, Installation.

  • Step3: Open the configuration tool on the PC and click the “connect” button to connect the EPEVER RTU 2G A successfully.

  • Step4: Click the “Read” and “Write” buttons to configure the parameter. Step5: After configuring, power on the product again to make the modified parameters take effect.

Common configuration parameters:

Parameters Configuration
Server Info No modifications are recommended


APN

| Different countries have different APN, and please make sure APN firstly. Products will not be connected to the Internet with fault APN.

China APN: CMNET

APN User| Enter it according to the actual
APN Key| Enter it according to the actual
Baud| Set it according to the connected controller or inverter

System Connection

EPEVER RTU 2G A can be applied to the following solar street light systems. Through a GPRS signal, users can easily monitor the operating status and modify the related parameters on the Cloud platform.

EPEVER RTU 2G A GPRS Transmission Terminal fig3

Note: The EPEVER RTU 2G A supports 5~18V DC power. While a larger transient current is needed when the wireless network sends the data, it is suggested to adopt a power adapter of DC 5V/500mA or above.

Installation

  1. Install the SIM Card

  2. Purchase a SIM card and activate the GPRS service.

  3. Undo the three screws from the EPEVER RTU 2G A.

  4. Push the shell upward and take out the circuit board.

  5. Take out the small SIM card and insert it into the card slot correctly.EPEVER RTU 2G A GPRS Transmission Terminal fig4

  6. After installing successfully, reinstall the product shell.

  7. Install the silicone pad
    Tear off the silicone pad’s adhesive and stick the silicone pad to the DB9 terminal of the EPEVER RTU 2G A.

  8. Install the antenna
    Connect the 4G antenna to the antenna port of the EPEVER RTU 2G A.EPEVER
RTU 2G A GPRS Transmission Terminal fig5Caution: As a wireless terminal, keep the antenna away from the human body as far as possible during the operation process.

  9. Connect the controller
    Connect the EPEVER RTU 2G A to the controller’s com. port through a DB9 adapter.

Applications

According to different applications, the cloud platform provides two networking connection methods: “one-to-one” and “one-to-more.” Controllers can be added into the system convenient and flexible by the two methods. Users can remote control or real-time monitor the controller through the cloud platform. EPEVER RTU 2G A GPRS Transmission Terminal fig6 EPEVER RTU 2G A GPRS Transmission Terminal fig7

After adding the device into the Cloud platform successfully, log in to the cloud platform (https://iot.epsolarpv.com), remotely monitor the real-time condition or set the parameters.
Note: For new accounts, devices need to be manually added in the EPEVER cloud before monitoring.

Specifications

Item Specifications
Network type GPRS class12
Coding method CS1 – CS4(Comply with SMG31bis)
Frequency GSM850/EGSM900/DCS1800/PCS1900MHz
GPRS transmission rate 85.6kbps
Network protocol TCP/UDP/FTP/PPP/DNS
SIM card voltage 3V/1.8V
Antenna connector 50Ω IPX connector
--- ---
Serial port level type RS485
Serial port baud 9600~115200bps
Power DC: 9~ 60VDC or 5VDC
Power consumption Communication: <200mA/5V; Idle: <40mA/5V
Environment temperature -40~85℃
Humidity 0~95%(Non-condensing)
Electromagnetic compatibility Electrostatic discharge immunity test, level 3

Anti-interference test, level 3

Troubleshooting

Faults Solutions




LED indicator OFF

| 1.   Check whether the power supply is correct.

2.   Check whether the power supply’s poles are connected inversely. The EPEVER RTU 2G A is equipped with anti- reverse protection. The reverse connection does not cause fatal damage. However, it affects the regular use

before the correct connection is restored.





Network indicator ON solid

| After power is on, the network indicator is on solid in 60 seconds. If it still cannot flash after 60 seconds, please check:

1.   Check whether the SIM card is inserted correctly.

2.   Check whether the GPRS service is activated. Network indicator on solid again after running for a while:

1.   Check whether the server status is normal.

2.   Check whether the SIM card is loose or arrear.


Smoke emits with a pungent smell

| The actual voltage exceeds the rated voltage, causing the internal components to burn out. Don’t hesitate to contact the

supplier in time and send it to the manufacturer.



Unregister on the network

| 1.  Check whether the SIM card is inserted correctly.

2.  Check whether the SIM card has activated the GPRS service.

3.  Check whether the input power is sufficient. Input power

should be 12VDC/0.2A or 5VDC/0.2A.

Parameters can’t be configured| 1.  Check whether the connection to the PC is correct.

2.  Check whether the serial port selection is correct.

Dimension

EPEVER RTU 2G A GPRS Transmission Terminal fig8

Any changes without prior notice! Version number: 3.2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)