MARTEC Flow Series Ceiling Mounted Exhaust Fan or Fan and Light Instruction Manual
- June 6, 2024
- martec
Table of Contents
MARTEC Flow Series Ceiling Mounted Exhaust Fan or Fan and Light
INSTALLATION
Cutting a vent (when required)
For installation where external venting is required or is your choice, locate a suitable location in either the roof or exterior wall to vent out the exhausted air / steam and cut out a 105mm diameter hole.
-
Ducting Put one end of a 100mm diameter ventiduct (not supplied) into the vent hole and seal space around the hole using a suitable sealant and cowling where necessary.(Figure1)
-
Locating the unit
For the fan to work efficiently, from the grill there should be about a 2.3m overall height to ground. -
Prepare the ceiling
Use this card as a template, mark the ceiling with a pencil outline and cut out a hole in the ceiling at the chosen area. Make sure a distance between the edges and wall no less than 250mm. Also from the rooftop there should be a minimum 250mm height to the ceiling. (Figure 2)
Ensure that the intended hole will have suitable room to the unit and will not foul on joists or not fit in the headroom provided. -
Remove the fascia Pull the fascia a little, press the fascia retaining springs backside and remove the fascia. Remove the LED globe first if the unit is an Exhaust Fan & Light model.
-
Wiring (Ensure the power is turned off) Please comply with the local wiring rule when wiring. Wire the unit as per the wiring diagram. For Exhaust Fan model, please refer to Figure 3. For Exhaust Fan & Light model, please refer to Figure 4.
-
Position the housing into the hole
Choose an optimal direction to put the housing into the hole in accordance
with the position of fan outlet. Fit the fan outlet to the in-house end of the
ventiduct, then put the body of the unit into the hole in the ceiling.
Note: Try to keep the redundant wire away from the housing.
Note: The shortest, smooth surface ventiduct with the least elbows will
provide optimum fan performance. Please keep the ventiduct as straight as
possible. (Figure 5)
Note : Ensure the 4 slips are drawn back so the unit can be easily pushed
into the hole in the ceiling.
Note : It is highly recommended that interconnected wire be laid into the
wall beforehand for the purpose of keeping an integrated look in the bathroom.
-
Fasten the unit on the ceiling
Push the 4 slips outwards and then tighten the screws until the clips can clamp the ceiling tightly. (Figure 6) -
Replace the fascia
Put the two fascia retaining springs on the fascia into the two slots in the unit and make sure the fascia is well fixed.
USE
Running the fan can exhaust odours and steam in a quick and efficient way.
Note: Shut off power urgently when any abnorrnalities occur in operation.
Then call your local licensed electrician for inspection or necessary service
work.
Note: It is absolutely prohibited to insert finger or thin bar to the
fascia for avoiding being injured or damaging the unit.
MAINTENANCE
Cleaning
- Shut off power before cleaning or maintenance.
- Wipe fascia with care using a soft cloth soaked with water or neutral detergent. Ensure the motor or other electrical parts can not touch the water.
- Replace the fascia after it is dry thoroughly.
LED Light Models only
Tri-colour 12w integrated LED Light included
WARRANTY
This unit is warranted against defects in manufacturing and workmanship for a
period of 2 years. The warranty does not extend to installation of the unit or
any associated wiring or any damage caused by installation or wiring. The
installation must be conducted by a licensed electrician and a suitable
certifi cate of safety is to be issued by the electrician who installed the
unit. Warranty claims will be voided unless a certificate of safety can be
produced when required, prior to service or repair.
This warranty does not cover damages or loss caused by:
- Light lamp or failure of light lamp.
- Any consequential losses arising from incorrect installation or operation or maintenance of this product.
- Any consequential losses arising from incorrect wiring of this product.
- Any modifications or changes make to the unit, other than those recommended by the Manufacturer.
ACCC Required Statement
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to Marlee replacing the product in home with
parts and labour for a major failure. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure. Martec offers an in home warranty
that includes parts and labor so the end consumer is not out of pocket.
MAIN TECHNICAL PARAMETERS
WARNING
Dear customers,
Thank you for selecting Martec ceiling-mounted Exhaust Fan or Fan & Light.
Please read all instructions before commencing installation.
IMPORTANT: This unit must be installed to comply with the appropriate
council regulations and the Australia and New Zealand wiring rules
AS/NZS3000:2000 or latest edition thereof.
This unit is fitted with a plug(Exhaust Fan model only), however, any
interconnecting wiring and switches used or use of another plug must be fitted
by a licensed Electrician. The plug supplied must be connected to the socket
that is above the ceiling or in roof cavity, any other use is not permitted.
The main supply, switches and interconnecting cables required for installation
of this unit are not included.
- Use this unit only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. If you have any question, contact the manufacturer or local agent.
- All wiring must be carried out by a Licensed Electrician in accordance with all applicable National / local codes and standards. Also check with the local council regulations regarding installation of exhasut fans.
- Make sure the power is off before installation.
- When cutting into the ceiling, do not damage electrical wiring and other hidden utilities.
- The unit must be properly earthed
- For the purpose of avoiding any dangerous gas leaking into your bathroom, the ventiduct of the unit must not be laid together with the ventiduct of air-fueled water heater or other open fire appliances into the same flue.
- The unit must be isolated from the power by means of a plug or all-pole disconnection switch with a contact separation of at least 3mm in each pole.
- The power cable must withstand a minimum 1 0A load.
- The unit is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the unit safely.
- Young children should be supervised to ensure that they do not play with the unit.
IMPORTANT CONSIDERATIONS BEFORE INSTALLING
A few minutes planning can make a big difference to the installation time and
also to your satisfaction with the function of the unit.
- Generally the unit should be mounted outside the shower cubicle.
- For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. In general this air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will function poorly.
- This unit is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling or a vertical wall.
- Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall switch to the mounting location.
INSTALLATION INSTRUCTION AND HOLE-CUTTING TEMPLATE
READ AND SAVE THESE INSTRUCTIONS!
HOLE CUTTING SIZE: DIAMETER 240MM
How to change the light colour temperature
- Remove the cover on the unit by simply pulling down & pinching the springs to release the cover from the unit. On the back there is a white square box with the letters C N W at the top of the box and a black toggle switch below.
- Slide the switch to the desired colour. C = Cool white N = Neutral white W = Warm white
Please note, the light will have a cord attached. Be careful not to pull this cord out.
Documents / Resources
|
MARTEC Flow Series Ceiling Mounted Exhaust Fan or Fan and
Light
[pdf] Instruction Manual
Flow Series, Ceiling Mounted Exhaust Fan or Fan and Light, Flow Series Ceiling
Mounted Exhaust Fan or Fan and Light, MXFFR25W, MXFFS25W, MXFLFR25W, MXFLFS25W
---|---
|