novopress ACO203 Copper Press 18V Battery Tool Kit
Proper use
These press devices are intended exclusively for use with press jaws/adaptor
jaws and press collars manufactured by Novopress or approved by Novopress in
agreement with the system supplier. For further details, please contact the
system supplier or Novopress direct.
The devices, press jaws and press collars are to be used exclusively for the
purpose of press-fitting pipes and fittings for which the relevant press jaws
and press collars have been designed. Any use beyond or different to that
described here shall be regarded as improper use.
All work with this tool that does not correspond to proper use may lead to
damage to the press device, the accessories or the pipes. Leaks and/or injury
may result.
Novopress is not liable for damage resulting from
- the use of unsuitable press tools or press tools from other manufacturers, or
- applications that do not conform to proper use.
Proper use also includes compliance with the Operating Manual, adherence to the inspection and maintenance conditions as well as compliance with the latest versions of all relevant safety regulations.
Basic safety information
The following pictograms are used to highlight sections of text. Please follow these instructions and act with particular caution in these cases. Pass all health and safety instructions on to other users and technicians.
Please read this Operating Manual carefully. The safety instructions it
contains must be observed. Compliance with local safety regulations is
essential!
WARNING!
Read all safety warnings and all instructions. Failure to follow the warnings
and instructions may result in electric shock, fire and/or serious injury.
Therefore: Save all warnings and instructions for future reference.
WARNING!
Risk of injury from ejected fragments
Incorrect or improper use or the use of worn or damaged press tools and press
devices carries a risk of injury from ejected fragments.
Therefore:
- Press tools and press devices may only be used by trained personnel.
- Compliance with the specified service work and service intervals is mandatory.
- Check the press tools and press devices for cracks and other signs of wear before each use.
- Separate all press tools and press devices with material cracks or other signs of wear immediately and do not use them any longer.
- Only use press tools and press devices that are in perfect technical condition.
- Following incorrect use, do not use the press tool and press device any longer and have them inspected by an authorised workshop.
CAUTION!
Unskilled use may lead to a damaged or malfunctioning press tool and press
device.
Therefore:
- Replace worn press tools immediately and do not use them any longer.
- Use carrying cases for transport and storage and keep press tools and the press device in a dry room.
- Have damage checked immediately by an authorised workshop.
- Comply with the safety instructions regarding the cleaning and anti-corrosion agents used.
Information!
Consult the documents provided by the system supplier for handling and
assembly instructions for fittings and pipes
Definition of terms
Symbols on the device and information on the rating plate
Explanation of possible pictograms on the rating plate
Scope of supply
The scope of supply for the standard equipment includes
Technical data
The stated vibration emission value was measured using a standard test
procedure and can be employed for the purpose of comparison with another
device. The stated vibration emission value can also be used to obtain an
initial estimate of interruptions during intermittent operation.
Caution The vibration emission value may differ from the stated value while
the device is actually in use, depending upon the manner in which the device
is used. It may be necessary to establish safety measures to protect operating
personnel, depending on the actual conditions of use (intermittent operation.
Battery charger
For information on the function and operation of the battery charger and the
rechargeable batteries, please consult the battery charger operating
instructions.
Brief description of the press device
Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing
operation is always completed. The automatic press cycle is activated after
approx. 1.5 seconds. After the automatic press cycle has been triggered, the
green LED (2) goes out and the pressing operation runs automatically.
The pressing operation can then only be stopped by pressing and holding
release button (5). After the pressing operation has been completed, the motor
automatically switches off and the green LED (2) lights up again.
If the start button (1) is released before the automatic press cycle begins,
the piston in the press device moves back to its starting position. The
pressing operation will not have been completed. The pressing operation must
be triggered again.
Release button (Fig. 1)
The pressing operation can be stopped at any time by pressing and holding the
release button (5). The piston in the press device then returns to its
starting position.
Pressing point lighting
When the start button (1) is pressed, the pressing point is lit by 2 LEDs
(12). If the press device is out of use for a longer period, the device and
the LEDs switch off.
Wireless interface (only ACO203 BT)(Fig. 1)
The ACO203 BT device features a wireless interface if it shows the following
characteristic:
-
Blue LED (10)
This wireless interface together with the NovoCheck app can be used to connect the ACO203 BT to a mobile terminal device, such as a smartphone, tablet, etc. (Android, IOS; further information at www.novopress.de). The following functions are available: -
Reading the press device
-
Checking the press device
-
Making settings
-
Generating construction site reports. To establish a connection, the press device must be operational and the NovoCheck app installed on the terminal device.
The press device can now be connected with the NovoCheck app. (For more
information, go to www.novopress.de) When the
connection to the wireless interface was established successfully, the blue
LED (10) lights up.
The blue LED (10) goes out if no connection has been established until the
first pressing operation is performed. A new attempt to establish the
connection can only be made if the press device has been switched off in the
meantime. It may be necessary to pull the rechargeable battery for this. If
you do not wish to establish a connection, press the start button (1) once
again and perform the pressing operation.
Battery (ACO203 / ACO203 BT only)
Information!
The batteries are not charged at the factory.
Therefore:Charge the batteries before using for the first time.
Information!
Limited temperature range for charging and storing the batteries.
Therefore: It is imperative that the operating instructions for the battery
charger are complied with
Removing the battery (Fig. 2)
Push in (1) the two release buttons (A) and then remove the battery (2).
Inserting the battery (Fig. 3)
Slide the battery into the device as illustrated until it clicks into place.
Battery charge indicator (Fig. 2)
The battery charge is displayed when button (B) is pressed. The number of LEDs
lit up denotes the battery charge. One flashing LED indicates a maximum power
reserve of 10%. The battery must be charged soon.
If the battery is inserted in the press device while the battery charge is
being checked, the last pressing operation must have been completed at least 1
minute prior to this. Otherwise the display will be inaccurate.
Feature of the press device when the battery is empty:
When a pressing operation begins, a check is made to determine whether the
battery charge is sufficient to complete the pressing operation. If this is
not the case the device does not start. The green LED (2) flashes.
If the green LED (2) flashes following a pressing operation, the pressing
operation was carried out correctly. The battery must be recharged prior to
the next pressing operation.
Energy saving mode
If the press device is not used over an extended period, the device switches
off. No LED is lit up any longer. Press the start button (1) briefly to
activate the press device.
Commissioning and operation
Preparing the ACO203 / ACO203 BT / ECO203
CAUTION!
Fingers risk being crushed if the device is operated without a press
jaw/adaptor jaw (Fig. 4) If no press jaw/adaptor jaw is fitted, fingers could
be placed in the at-risk zone. Fingers could be crushed when the device is
started.
Therefore:
- Do not operate the device without press jaws.
- Keep your fingers away from the at-risk zone.
Meaning of the LED display
Performing the pressing operation
CAUTION!
Danger of crushing!
There is a risk that fingers and hands will be crushed.
Therefore:
- Keep body parts and foreign objects away from the press jaws during the pressing operation.
- Do not hold the jaw levers with your hands during the pressing operation.
CAUTION!
Keep fingers away from the at-risk zone if no press jaw/adaptor jaw is fitted.
(Fig. 4)
Fingers risk being crushed.
Therefore:
- Do not operate the device without the jaws.
- Keep your fingers away from the at-risk zone.
- Check whether the nominal width of the press fitting matches the nominal width of the press jaw/press collar.
- Comply with the system manufacturer’s instructions when fitting the press jaw/press collar (Fig. 8). If using a press collar: Fit the adaptor jaw to the press collar as described in the press collar manufacturer’s instructions.
Information!
Make sure that the press jaw is fully closed when pressing is complete (Fig.
9).
Information!
Ensure there is no gap between the segments of the press collar when the
pressing operation is complete.
3. To start the process, press the start button.
4. When pressing is complete:
- If using a press collar: First detach the adaptor jaw from the press collar, then
- Detach the press jaw/press collar from the press fitting (Fig. 10).
Cleaning, maintenance and repair
CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing the
On switch.
Therefore:
- Comply with the safety instructions and always remove the battery or disconnect the mains plug before performing cleaning, maintenance or repair work.
Service addresses
Novopress GmbH Pressen und Presswerkzeuge & Co. KG
Welserstr. 7
41468 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting
Novopress or at
www.novopress.de.
Service intervals
Service and repair work may only be carried out by Novopress or the authorised
Novopress specialist workshops.
Routine inspection (before use, at the start of the working day) and when
soiled (Fig. 11)
Check for visible damage, material cracks and other signs of wear. If defects
are found, do not use the device and have it repaired.
Six-monthly inspection
Have the device inspected by a qualified electrician or a Novopress workshop
Annually to get a 1-year extended warranty (see section 11 Warranty and guarantee) Have the press device inspected and serviced at Novopress or a Novopress workshop.
Disposal
CAUTION!
Groundwater hazard
The device contains hydraulic fluid. Hydraulic fluids pose a hazard to
groundwater. Uncontrolled drainage or improper disposal is punishable by law.
Therefore: Dispose of the device in an environmentally responsible manner
The instructions in the operating instructions provided with the battery
charger must be complied with when disposing of rechargeable batteries and the
charger.
The product must not be disposed of as normal household waste.
Novopress recommends that disposal be carried out by authorised specialist
companies.
Alternatively, waste devices can be returned directly to Novopress (or a
specialist workshop) for proper disposal.
Warranty and guarantee
Novopress provides the full statutory warranty of 24 months for its press
devices and tools. The warranty period always commences on the date of
delivery, which must be proven by means of the sales documentation in case of
doubt.
Within the warranty period, the warranty covers the repair of any damage or
malfunction of these tools that is attributable to material or production
faults.
The following are not covered by the warranty:
- Damage caused by improper use or inadequate servicing.
- Damage caused by the use of products not approved by Novopress for use with its press devices.
- Damage caused by pressing unsuitable pipes or fittings.
For wearing parts, the Novopress warranty lasts only for the intended service
life. Service work and parts provided in response to warranty claims do not
have to be paid for. However, all shipping costs shall be borne by the user.
Claims can only be accepted if the device is delivered to Novopress or a
Novopress workshop in an assembled state.
Repair or replacement of the device under warranty does not result in an
extension of the warranty period. Repair or replacement can only be performed
using as-new components, the function of which corresponds to that of the old
components. All parts that are faulty and consequently replaced are the
property of the manufacturer.
Extended warranty on expiry of the statutory warranty period
We voluntarily provide the following extended warranties beyond the statutory
warranty period 1-year extended warranty for new press devices, adaptor jaws
and press collar
Novopress provides an extended warranty of one year for all new press devices,
adaptor jaws and press collars that have been serviced at least every 12
months by Novopress or by an authorised Novopress workshop. There is a charge
for this service work. For details of costs, please contact Novopress or an
authorised Novopress workshop.
3-year extended warranty for new press jaws
Novopress provides an extended warranty of three years for all new press jaws,
interchangeable jaws and press inserts that have been serviced at least every
12 months by Novopress or by an authorised Novopress workshop. There is a
charge for this service work. For details of costs, please contact Novopress
or an authorised Novopress workshop.
Repair warranty
Novopress provides the following repair and spare parts warranty beyond the
warranty period for new products that undergo repair after this period:
- 6-month warranty for replaced spare parts.
- 12-month warranty for replaced assemblies.
- 12-month warranty for replaced press devices.
EU Declaration of Conformity
EU declaration of conformity and list of maintained directives and applicable
standards see attached document EU declaration of conformity.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>