Clarke BOXER II 14/200 200L Belt Driven Air Compressor Instruction Manual

June 6, 2024
Clarke

Clarke logo

Clarke BOXER II 14/200 200L Belt Driven Air Compressor

Clarke BOXER II 14 200 200L Belt Driven Air Compressor

INTRODUCTION
Thank you for purchasing this CLARKE Air Compressor.
Before attempting to operate the machine, it is essential that you read this manual thoroughly and follow all instructions given. This will ensure the safety of yourself and others and you can look forward to the product giving you long and satisfactory service.

ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.

GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.

SAFETY PRECAUTIONS

Before using your compressor it is in your own interest to read and pay attention to the following safety rules.

  1. Compressed air is dangerous. DO NOT point a jet of air at persons or animals, and do not discharge compressed air against the skin.
  2. DO NOT operate your compressor with the guard removed.
  3. Repairs must only be carried out by a qualified engineer. If problems occur, contact your CLARKE dealer.
  4. Before carrying out any maintenance make sure that the pressure is released from the air reservoir and that the compressor is disconnected from the electrical supply.
  5. DO NOT leave pressure in the receiver overnight or when transporting.
  6. DO NOT adjust or tamper with the safety valves. The maximum pressure is factory set, and clearly marked on the compressor.
  7. DO NOT operate in wet or damp conditions. Keep the compressor dry at all times. Similarly, clean air will allow the compressor to work efficiently. DO NOT use in dusty or otherwise dirty locations.
  8. Some of the metal parts can become quite hot during operation. DO NOT touch/remove these until the compressor has cooled down.
  9. When spraying flammable materials e.g. cellulose paint, ensure that there is sufficient airflow and keep clear of any source of ignition.
  10. Before spraying any material always consult paint manufacturers instructions for safety and usage.
  11. Protect yourself. Goggles will protect your eyes from flying particles. Face masks will protect you against paint spray and fumes.
  12. DO NOT apply strain to electrical cables and make sure that air hoses are not kinked or wrapped around the compressor.
  13. When disconnecting air hoses or other equipment from your compressor, make sure that the air supply is turned off at the outlet and vent all pressurised air from within the reservoir and other equipment attached to it.
  14. Make sure that children and animals are kept well away from the compressor and any equipment attached to it.
  15. Make sure that all individuals using the compressor have had any necessary training and have read and fully understand these operating instructions.
  16. Make sure that any equipment or tool used in conjunction with your compressor, has a safe working pressure exceeding that of the compressor.
  17. Be careful when transporting the compressor to prevent tipping over.
  18. Permanently installed systems must be installed by a competent engineer.
  19. These compressors produce noise levels in excess of 70dB(A). Persons working near the compressor must be supplied with ear protection.

SAFETY SYMBOLS

SAFETY SYMBOLS

ELECTRICAL CONNECTIONS

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions shown below. The old plug must be discarded safely, as insertion into a power socket could cause an electrical hazard.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH

  • The BLUE wire must be connected to the terminal which is marked N or coloured black.
  • The BROWN wire must be connected to the terminal which is marked L or coloured red.
  • The YELLOW AND GREEN wire must be connected to the terminal which is marked E or coloured green.

ELECTRICAL CONNECTIONS 1

We strongly recommend that this machine is connected to the mains supply through a Residual Current Device (RCD).
If you are not sure, consult a qualified electrician. DO NOT try to do any repairs.

BEFORE USE

CAUTION: TO PREVENT INJURY, GET ASSISTANCE WHEN LIFTING OR MOVING THIS COMPRESSOR.
Before connecting your compressor to the power supply, check the following:

  • Set the ON/OFF switch to the OFF position (pushed down).
  • Make sure that the compressor is on level ground.
  • Make sure that the supply voltage matches the voltage shown on the data label.

BEFORE USE 1

CHECK THE OIL LEVEL

  1. Remove the dipstick from the oil reservoir.
  2. Ensure the oil level is between the min and max marks on the dipstick.
    • Only use CLARKE ISO100 (SAE30) compressor oil, available from your CLARKE dealer Part No. 3050796.
    • Take care not to fill above the maximum mark.

BEFORE USE 2

OPERATION

If the compressor has not been used for more then 24 hours, open the drain valve (on the bottom of the reservoir) and drain any condensate which has collected. See page 10.

MOVING THE AIR COMPRESSOR

  • Stop the compressor and disconnect it from the power supply before you move it.
  • Do not lift by (or put strain on) valves or hoses.
  • Avoid moving the machine if the tank is fully pressurised.

ATTACHING AIR TOOLS

WARNING: BEFORE CONNECTING AIR TOOLS, MAKE SURE THAT YOU READ THE INSTRUCTIONS SUPPLIED WITH THE TOOL, ALSO ENSURE THAT THE TOOL IS SUITABLE FOR USE WITH THE COMPRESSOR AND HOSE SPECIFICATIONS.

  1. Attach the air hose to the outlet valves.
  2. Attach the air tool to the other end of the air hose.
  3. Turn the outlet valve handle to the on position.

OPERATION 1

NOTE: The outlet valve is shown without the air hose fitted for clarity.
NOTE: To adjust the output pressure we recommend that a pressure regulator (not supplied) be fitted between the compressor and the tool.

TURNING THE COMPRESSOR ON

  1. Plug the compressor into the power supply.
  2. Lift the On/Off button.
    • The compressor will operate until the reservoir is fully pressurised. It will then shut down.
    • The compressor will start up again when the pressure in the reservoir decreases.

TURNING THE COMPRESSOR ON

CHECKING THE SAFETY VALVE
To make sure that the safety valve works correctly;

  1. Unscrew and pull the knurled part of the safety valve.
    • Air will be released when you pull hard on the valve end and stop when released.
  2. If the valve does not operate in this way, do not use the compressor. The compressor must be repaired by a qualified service agent.
  3. Once tested, screw the knurled part back.

CHECKING THE SAFETY VALVE

WARNING: DO NOT REMOVE OR TRY TO ADJUST THE SAFETY VALVE.

REMOVING TOOLS FROM THE AIR HOSE

  1. Push down on the On/Off button to stop the compressor.
  2. Turn the outlet valve handle to the off position.
  3. Operate the tool to depressurise the air hose.
  4. Disconnect the tool from the hose.

OPERATION 1

TURNING THE COMPRESSOR OFF

  1. Follow steps 1-3 in “Removing Tools from the Air Hose” above.
  2. Disconnect the compressor from the power supply.
  3. Slowly open the outlet valve to depressurise the reservoir.
    • You will hear a hissing sound as the reservoir depressurises.
  4. Do not leave the compressor unattended if the reservoir is pressurised.

DRAINING THE RESERVOIR

CAUTION: YOU MUST DRAIN THE RESERVOIR AFTER EACH DAYS USE AND BEFORE YOU PUT YOUR COMPRESSOR INTO STORAGE.

  1. Turn the compressor off and disconnect from the power supply.
  2. Put a container below the drain valve to collect the condensate.
  3. Open the drain valve slowly.
    • Condensation will drain from the reservoir.
  4. Close the drain valve when the reservoir has fully drained.

DRAINING THE RESERVOIR

USING THE RESET BUTTON
This compressor has a thermal overload device.
If the motor gets too hot, the thermal overload device cuts the power which prevents damage to the motor.
If the thermal overload device operates, let the motor cool down for 5 minutes and push the reset button.
If you start the compressor and the overload cutout operates again, stop the compressor and disconnect from the power supply and have your compressor examined by a qualified service agent.

USING THE RESET BUTTON

MAINTENANCE

WARNING: MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE

DRAIN THE RESERVOIR
After use, always open the drain valve to make sure that any condensate is drained off.

CHECKING THE OIL
Ensure the oil level is between the min and max marks on the dipstick. See “Check the Oil level” on page 6 and top-up if necessary – (use CLARKE ISO100 (SAE30) compressor oil, available from your local CLARKE dealer).

CLEANING THE AIR FILTER
The air filter must be examined monthly or more often in dusty conditions.

  1. Remove the securing bolt and pull the filter from the compressor.
  2. Unclip the front and rear of the filter and pull out the filter element.
  3. Clean the filter using a soft brush.
    • If necessary, the filter can be carefully cleaned in warm soapy water.
    • Rinse and let the filter dry completely before refitting.
    • If the filter or filter element is damaged you must replace it.
  4. Reassemble the filter and refit it to the compressor using the securing bolt.

MAINTENANCE 1

REPLACING THE OIL
After the first 100 hours use, replace the oil using CLARKE ISO100 (SAE30) compressor oil. Then replace the oil after every 500 hours of operation or every 6 months.
To empty the oil from the machine, remove the oil drain plug from the crankcase.

MAINTENANCE 2

CHECKING THE NON-RETURN VALVE
If the reservoir pressure decreases for no apparent reason, it is possible that the non-return valve is leaking. To check this;

  1. Make sure that the reservoir is not under pressure and the compressor is switched OFF.
  2. Examine the non-return valve, and replace the gasket and valve if necessary.

MAINTENANCE 3

REPLACING THE DRIVE BELT
WARNING: MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE REPLACING THE DRIVE BELT.

  1. Rotate the clips on the front of the safety cage.
  2. Remove the front of the cage and take out the worn or broken drive belt.
  3. Place the new drive belt over the small pulley.
  4. Position part of the drive belt over the large pulley as shown.
  5. Rotate the large pulley by hand in a clockwise direction whilst guiding the belt on to it.
    • Take care to avoid trapping your fingers between the pulley and belt.
  6. Replace the cage and secure before use.

REPLACING THE DRIVE BELT

WARNING: NEVER USE THE COMPRESSOR WITH THE GUARD REMOVED.

TROUBLESHOOTING

CAUTION: DO NOT TRY TO REPAIR OR ADJUSTMENT IF YOU ARE UNCERTAIN. IF YOU HAVE ANY QUERIES, CONTACT YOUR CLARKE DEALER.

PROBLEM PROBABLE CAUSE REMEDY
The compressor has stopped and does not start. Bad electrical connections.
  1. Check electrical connections.
  2. Clean and tighten if necessary.

Overload cutout switch has tripped.|

  1. Switch off and wait approx 5 minutes.
  2. Press the reset button and switch on again.

Motor windings burnt out.| 1. Contact your CLARKE dealer for a replacement motor.
The compressor does not reach the set pressure and overheats easily.| Compressor head gasket blown or valve broken.| 1. Return the machine to your nearest CLARKE dealer.
Compressor does not start.| The reservoir has already fully pressurised.| 1. Open drain valve to expel air. Compressor should start again when pressure reduces.
Air leaking from the non-return valve when the compressor is not running.| Faulty non-return valve.|

  1. Drain receiver completely of air.
  2. Remove the valve end plug.
  3. Carefully clean the valve seat and the gasket
  4. Reassemble.

Compressor is very noisy and makes metallic knocking sound.| Compressor is damaged and needs overhaul.| 1. Return the machine to your nearest CLARKE dealer.

COMPONENT PARTS

COMPONENT PARTS 1

COMPONENT PARTS 2

COMPONENT PARTS LIST

  1. CRANKCASE
  2. CYLINDER BODY
  3. CYLINDER HEAD
  4. CRANKSHAFT
  5. LOWER COVER
  6. VALVE HOLDER ASSEMBLY
  7. CONROD
  8. INTAKE FILTER ASSEMBLY
  9. AIR COOLER
  10. END COVER
  11. BEARING HOUSING
  12. FLYWHEEL
  13. BEARING
  14. DIPSTICK
  15. OIL SEAL
  16. O-RING
  17. BOLT
  18. WASHER
  19. COLD START VALVE
  20. SHROUD
  21. CYLINDER HEAD BOLT
  22. GASKETS SET COMPLETE
  23. PISTON RING SET
  24. PISTON ASSEMBLY
  25. CHECK VALVE
  26. TAP BALL VALVE
  27. TAP BALL VALVE
  28. GAUGE 50 mm
  29. SAFETY VALVE
  30. OUTLET CONNECTOR
  31. ON/OFF PRESS SWITCH
  32. POWER CABLE
  33. MOTOR
  34. BELT GUARD
  35. AIR DELIVERY TUBE
  36. PUMP ASSEMBLY COMPLETE
  37. RUBBER FEET (X4)
  38. RILSAN TUBE
  39. DRIVE PULLEY
  40. DRIVE BELT

SPECIFICATION

MODEL B OXER II 14/200
Part Number 2245315
Motor Power 3 HP
Voltage 230 VAC (50Hz)
Air Displacement 394L/min (14 cfm)
Max Pressure 10 Bar (145 psi)
Receiver Capacity 200 L
Ingress Protection IP20
Fuse Rating 13 A
Duty cycle S3/50%
Oil requirements ISO100 (SAE30) compressor oil
Oil capacity 0.4L
Dimensions (L x W x H) 1540 x 400 x 830 mm
Guaranteed Sound Power Level 97 dB(A)
Weight 97 kg

Parts & Service: 020 8988 7400 /
E-mail: Parts@clarkeinternational.com
Service@clarkeinternational.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals