WARNING: Do not use the generator without reading this manual
INVERTER GENERATOR
MODEL NO: IG2000D
PART NO: 8877116
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS GC0521
INTRODUCTION
Before you use this product, read this manual and follow the instructions carefully. In doing so you will ensure the safety of yourself and others around you, and you can also expect your purchase to give you a long and satisfactory service.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is tampered with in any way, or not
used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be
returned to us without prior permission. This guarantee does not effect your
statutory rights.
ENVIRONMENTAL PROTECTION
Recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted and taken to a recycling
centre for disposal in a manner compatible with the environment.
By purchasing this product, the customer is taking on the obligation to deal
with its safe disposal in accordance with the Waste Electrical and Electronic
Equipment (WEEE).
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing Waste
Electrical and Electronic Equipment (WEEE) at a recognized disposal facility.
If disposing of this product or any damaged components, do not dispose of with
general waste. This product contains valuable raw materials. Metal products
should be taken to your local civic amenity site for recycling of metal
products.
GENERAL SAFETY RULES
WARNING: EXHAUST FUMES CAN BE EXTREMELY DANGEROUS IF INHALED
WORK AREA
- Always use in a well-ventilated area.
- Always position the exhaust outlet away from people.
- Read these safety instructions before using the equipment
- Keep children away from the generator.
PERSONAL SAFETY
- ALWAYS stay alert, watch what you are doing and use common sense when operating the compressor. Do not use the compressor while you are tired or under the influence of medication, drugs or alcohol. A moment of inattention can result in personal injury.
- NEVER over-reach. Keep your proper footing and balance at all times to enable better control of the compressor in unexpected situations.
- NEVER attempt any complex repairs yourself. If you have a technical problem contact your local Clarke dealer.
POSITIONING THE GENERATOR
- Keep the generator at least 1 m (3 ft.) from buildings or other equipment, or the engine may overheat.
- Place the generator on a solid, flat surface.
- Make sure the surrounding area is free from any material that could burn or be damaged by heat.
- Never move or tilt the generator whilst it is switched on.
FIRE PREVENTION
- Always switch the engine OFF when refueling.
- Always refuel in a well-ventilated area.
- Never overfill the tank, fill to the level specified (See “Check the fuel level” on page 12.)
- Never smoke whilst refueling and avoid smoking or using a naked flame near the generator.
- Never start the engine if there is spilled fuel. Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine.
PREVENTION OF ELECTRIC SHOCK
- Never use the generator in wet conditions unless it is well protected/ covered. Under these conditions, adequate ventilation MUST be provided
- Never operate the generator with wet hands
- Never use water or any other liquids to clean the generator.
- Make sure you ground (earth) the generator.
ADDITIONAL SAFETY RULES FOR GENERATORS
- Always make sure the applied load does not exceed the generator rating. Overloading the generator is dangerous and could cause serious damage.
- Always disconnect the generator when carrying out any maintenance.
- Always allow the generator to reach operating speed before connecting a load.
- Never allow the generator to run out of fuel when a load is connected.
- Never transport the generator with fuel in the tank.
- Never connect the generator to a commercial or residential power supply; e.g. ring main.
- Never allow the generator air vents to become blocked.
SAFETY SYMBOLS
The following safety symbols are shown on the product or it’s the packaging.
Please read all of the safety and operating instructions carefully before
using this product.
| Read this instruction booklet carefully before positioning, operating or
adjusting the compressor.
---|---
| This compressor produces a high sound level during operation.
Ear protection should be worn.
| This compressor contains surfaces that may get hot during operation.
Never operate with the motor housing removed.
| Risk of an accidental start-up. The compressor could start automatically in
the event of a power cut and subsequent reset. Do not carry the compressor
while it is connected to the power source, or when the receiver is filled with
compressed air.
| Risk of electric shock. The compressor must be disconnected from the
mains supply before removing any covers. Do not use in a damp environment.
****| Flammable
| Poisonous fumes – Do not use the generator in an enclosed space.
GENERATOR OVERVIEW – TBA
NO | DESCRIPTION | NO | DESCRIPTION |
---|---|---|---|
1 | Air Vent Knob | 10 | Earthing Point |
2 | Fuel Cap | 11 | Economy Control Switch |
3 | Fuel Valve Knob | 12 | AC Socket |
4 | Starting Handle | 13 | DC Socket |
5 | Side Maintenance Cover | 14 | DC Circuit Breaker |
6 | Top Maintenance Cover | 15 | Output Indicator |
7 | Muffler | 16 | Overload Indicator |
8 | Choke | 17 | Oil Alarm Indicator |
9 | Engine ON/OFF Switch | 18 | Primer Bulb |
After removing the generator from its packaging, check that it has not been damaged in transit. Report any damage immediately to the dealer where the item was purchased.
UNPACKING AND ASSEMBLY
Unpack your generator and check the following items are present. Should there be any missing or damage during transit contact your CLARKE dealer.
1 x 1800 Watt Inverter Generator | 1 x 12 Volt Connecting Lead Assembly |
---|---|
1 x Spark Plug Box Spanner | 1 x Instruction manual |
1 x Cross-head Screwdriver
BEFORE USING THE GENERATOR
IMPORTANT : Generators should ALWAYS be earthed. Make sure you earth
the generator.
Before using your generator check that:
- The generator is in good condition and free from any damage.
- The generator is clean and free from fuel or oil spillage.
- The generator is correctly located for use (see page 3).
- There is no leakage.
NOTE : To avoid accidental spillage of fuel, always use a funnel to fill the fuel tank. If fuel is spilled it must be removed from the unit before attempting to start the engine.
EARTHING
WARNING: IT IS ADVISABLE TO PROPERLY EARTH YOUR GENERATOR BEFORE
STARTING USING A WIRE AND A SMALL METAL-EARTH SPIKE. THE WIRE AND EARTH
SPIKE ARE NOT SUPPLIED WITH THE UNIT.
An earth spike and cable can be purchased at your local camping supplier,
or alternatively an earth spike can be made, and it is suggested you get
advice from a qualified electrician.
To make a spike use a copper tube or copper rod 12mm diameter, a minimum
length of 200mm, and with an M6 machine screw one end. The cable used should
be a maximum length of 1 meter and a minimum of 1.0mm 2 to carry a 10amp load.
Attach the cable to the generator at the earth point (shown on the right).
Connect the other end to the spike between a flat washer and the copper rod
with a lock washer under
the head of the M6 machine screw in a similar fashion to the earth point screw
on the generator.
When pushing the spike into the ground the generator must not be running and
it is suggested that the spike is pushed into the ground by at least 100 mm.
Earthing of generators is covered in BS7430:2011. If you have any doubts about
this subject consult a qualified electrician.
CHECKING THE AIR FILTER
-
Remove the side maintenance panel.
-
Remove the air filter cover screw shown on the right.
-
Slide-out the air filter panel.
-
Remove the air filter element.
-
If the air filter is damaged contact the CLARKE spare parts department for a replacement.
• If the filter is dirty, wash it in a solution of warm water and mild detergent and rinse thoroughly. Leave the filter to dry completely. Once it is dry immerse the filter in clean engine oil and squeeze the filter to remove excess oil.
WARNING: DO NOT USE FLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER. -
Replace the filter into its original position and replace and secure the air filter cover then replace the side maintenance panel.
**CHECKING THE ENGINE OIL LEVEL
**
WARNING : YOUR GENERATOR MAY NOT BE SUPPLIED WITH OIL. ALWAYS ENSURE
THAT THERE IS SUFFICIENT OIL BEFORE USE.
WARNING: TO CARRY OUT THIS CHECK, THE ENGINE MUST BE OFF.
-
Place the generator on a level surface and check the oil level as follows.
-
Remove the side maintenance panel.
-
Turn the oil filler cap anticlockwise and remove it from the oil reservoir, wipe the dipstick with a clean cloth.
-
Insert the dipstick back into the oil filler tube and then remove it again.
-
If the oil is below the Min. level on the dipstick, top up the oil reservoir with fresh oil.
• Do not fill above the max level mark (0.75 liters)
• We recommend the use of SAE30 oil in this generator. (CLARKE part number
- • Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.
- Replace the oil filler cap.
- Replace the left side maintenance panel.
CHECK THE FUEL LEVEL
WARNING: MAKE SURE THERE IS FUEL IN THE TANK WHEN USING THE GENERATOR. RUNNING OUT OF FUEL OR STOPPING THE ENGINE SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE.
-
To check the fuel level, open the fuel filler cap.
-
Slowly add fuel to the fuel tank (maximum
**2.1**
liters)
• Do not overfill the fuel tank. -
Replace the fuel filler cap securely.
WARNING: FUEL IS HIGHLY FLAMMABLE AND POISONOUS.
WARNING: SEE GENERAL SAFETY RULES ON PAGE 4 AND READ THEM CAREFULLY BEFORE
REFUELING.
WARNING: DO NOT FILL ABOVE THE TOP OF THE FUEL FILTER OR IT MAY OVERFLOW WHEN
THE FUEL HEATS UP AND EXPANDS.
WARNING: WIPE UP ANY SPILLED FUEL IMMEDIATELY.
WARNING: AFTER REFUELING, MAKE SURE THE FUEL FILLER CAP IS TIGHTENED SECURELY.
RECOMMENDED FUEL
Your generator has been designed to use regular unleaded petrol with an octane
number of 86 or higher.
USING YOUR GENERATOR
STARTING THE ENGINE
-
Remove all connections from the AC sockets.
-
Hold the fuel tank cap so that it will not move, and turn the air vent knob to the ‘open’ position.
-
Turn the fuel valve to the ON position (pointing right)
-
Set the engine switch to ‘ON’.
-
Move the choke lever to the right, to the ‘Choke’ position.
-
If this is the first time you are using the generator or if the generator had run out of fuel the last time you used it, pump the primer bulb a minimum of 6 times to introduce fuel into the carburetter.
-
Hold the generator handle firmly and pull the starting handle lightly until you start to feel resistance and then pull up sharply to start the engine.
NOTE : You may have to do this more than once.
WARNING: ONCE THE GENERATOR HAS STARTED, RELEASE THE STARTING HANDLE SLOWLY TO AVOID INJURY/DAMAGE AS IT WHIPS BACK.
NOTE: When you first start the generator, the overload indicator may light up for a few seconds, this is normal. If the overload indicator is still lit after 5 seconds, stop the engine and contact your CLARKE dealer.
-
Once the engine has warmed up, move the choke lever to the left, to the “run” position.
ECONOMY SWITCH
ON:
Recommended to minimize fuel consumption and further reduce noise levels when
no load is applied to the generator. Engine speed varies with the load.
OFF:
The smart throttle system does not operate.
CAUTION : THE ECONOMY CONTROL DOES NOT WORK EFFECTIVELY IF THE ELECTRICAL
APPLIANCE REQUIRES ‘BURSTS’ OF POWER.
CAUTION : TURN THE ECONOMY CONTROL FEATURE OFF WHEN
CONNECTING HIGH LOAD APPLIANCES OR WHEN CONNECTING TO THE DC OUTPUT.
CONNECTING ELECTRICAL DEVICES
The generator can supply both 230V
AC and 12V DC.
AC POWER
- Start the engine. See pages 11-13.
- Make sure the appliance is turned off before connecting it to the generator.
- Connect the appliance (max load
**800W**
) to the generator.
CAUTION : MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING
ORDER, IF IT BEGINS TO ACT ABNORMALLY OR STOPS SUDDENLY, DISCONNECT IT FROM
THE GENERATOR
CAUTION : MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM RATED LOAD
FOR THE GENERATOR.
CAUTION : ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E.G. DEVICES THAT
CONTAIN A MOTOR MAY REQUIRE MORE CURRENT ON STARTUP.
DC POWER
-
Set the economy control switch to ‘OFF’.
-
Start the generator. See page 11.
-
Make sure the appliance is turned off before connecting it to the generator.
-
Connect the 12V applience(max 4A) to the generator.
DC POWER (TOPPING UP CAR BATTERIES)
WARNING: FOR YOUR SAFETY PERFORM THE FOLLOWING INSTRUCTIONS IN THE
ORDER SHOWN.
WARNING: YOU SHOULD ONLY USE THIS GENERATOR TO ‘TOP UP’ THE BATTERY,
ALSO TRYING TO CHARGE A COMPLETELY FLAT BATTERY MAY CAUSE THE FUSE TO
BLOW.
-
Set the economy control switch to ‘OFF’.
-
Start the generator. See page 11.
-
Connect the battery charging leads to the battery.
• Make sure you clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. -
Connect the battery charging leads to the generator.
• The battery will begin to charge -
Monitor the voltage across the battery regularly during charging and disconnect the battery when the voltage reaches 14.4 volts.
CAUTION : WHEN DISCONNECTING THE BATTERY, ALWAYS DISCONNECT THE NEGATIVE
LEAD FIRST.
DC OVERLOAD PROTECTOR
If the DC overload protector activates, wait for a few minutes and then press
the reset button shown on the right.
INDICATOR LIGHTS
OUTPUT
The output indicator (Green) will remain on during normal operation.
OVERLOAD
The overload indicator (Red) will light up if there is an overload or a short
circuit in the connected appliance.
If this happens, proceed as follows:
-
Turn off any connected electrical devices and stop the engine.
-
Reduce the total wattage of connected electric devices to within the rated output of the generator.
-
Check air inlet and around the control unit. If any blockages are found, remove them.
-
After checking, restart the engine.
OIL ALERT
The oil alert indicator (Red) will light up when the oil level is low.
• To add oil, follow the instructions on page 11.
SHUTTING DOWN THE GENERATOR
To stop the generator in an emergency simply set the engine switch to ‘OFF’.
NOTE : Turn off any electric devices.
NOTE : Set the economy control switch to the ‘0’ (OFF) position.
-
Disconnect any electric devices.
-
Turn the fuel valve knob to “OFF” (pointing left).
-
Turn the air vent knob to the ‘Close’ position.
-
Set the engine switch to the “0” (OFF) position.
**MAINTENANCE
**
ENGINE OIL (EVERY 20 HOURS OF USE)
CAUTION: PROLONGED EXPOSURE TO USED ENGINE OIL IS DANGEROUS, ALWAYS WASH YOUR
HANDS THOROUGHLY AFTER HANDLING USED ENGINE OIL.
-
Remove the maintenance panel shown on the right.
-
Turn the oil filler cap anticlockwise and remove it from the oil tank.
-
Tilt the generator to allow the oil to drain out of the oil reservoir into a suitable container.
NOTE : You may need assistance with this step as the generator is heavy. -
Fill the oil reservoir with fresh oil.
• Do not fill above the max level mark (**0.25 liters)**
• We recommend the use of SAE30 oil in this generator. (CLARKE part number
- Replace the oil filler cap and maintenance panel.
ENVIRONMENTAL PROTECTION
One of the most damaging sources of pollution is oil. Do not throw away used
engine oil in with your domestic waste or down drains and sinks. Place it in a
leak-proof container and dispose of it according to local regulations.
AIR FILTER (EVERY 50 HOURS OF USE)
-
Remove the maintenance panel shown on the right.
-
Remove the air filter cover screw.
-
Remove the air filter panel.
-
Remove the air filter element.
-
If the air filter is damaged contact the CLARKE spare parts department for a replacement.
• If the filter is dirty, wash it in a solution of warm water and mild detergent and then rinse thoroughly.
• Leave the filter to dry completely, once it is dry immerse the filter in clean engine oil and squeeze the filter to remove excess oil.
WARNING: DO NOT USE FLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER. -
Replace the filter into its original position and replace and secure the air filter cover.
SPARK PLUG (EVERY 50 HOURS OF USE)
CAUTION : ALLOW THE ENGINE TO COOL BEFORE REMOVING THE SPARK PLUG.
-
Remove the top maintenance panel.
-
Remove the spark plug cap from the spark plug.
-
Fit the spark plug box spanner over the spark plug as shown.
-
Remove the side panel and use the screwdriver supplied to turn the spark plug box spanner as shown.
-
When the spark plug has been removed, check for discoloration and use a wire brush to remove any carbon build-up.
-
Check the spark plug gap (a) with a feeler gauge, it should be between 0.6 and 0.7 mm.
• Adjust if necessary. -
Check the overall condition of the spark plug and replace if damaged.
NOTE: Spark plugs are available from CLARKE Spare Parts department 020 8988 7400. -
Reinstall the spark plug and replace the spark plug cap and top panel.
FUEL TANK FILTER (EVERY 100 HOURS OF USE OR EVERY 6 MONTHS)
Just inside the fuel tank is a fuel filter, check this filter periodically and
remove any contaminants which may have accumulated.
-
Remove the fuel tank cap.
-
Lift out the filter inside.
-
Clean the filter with solvent. If the filter is damaged, contact CLARKE Spare Parts department 020 8988 7400 for a replacement.
-
Replace the filter and fuel tank cap.
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
---|---|---|
The generator fails to start | The engine switch is off. | Set the engine switch |
to ‘on’.
Not enough oil in the generator.| Add more oil, See page 11.
No fuel| Add more fuel, See page 12.
The spark plug not working correctly.| Change the spark plug, See page 21.
The generator fails to generate electricity| The device you are trying to
power is faulty.| Make sure the device you want to power is working properly.
The overload indicator is on.| Remove the appliance immediately, do not
connect any appliance that requires more than 800W.
(DC supply only) The DC Overload protector has been activated.| Press the
reset button. See page 17.
The generator is difficult to start| The air filter is dirty.| Clean the air
filter. See page 20.
If this does not solve your problem, please contact the CLARKE service department. see below.
SPECIFICATIONS
Engine | Engine Model | ( X552F-4) |
---|---|---|
Type | Petrol | |
Displacement (cc) | 99 | |
Ignition type | C.D.I | |
Fuel tank capacity (L) | 4.5 | |
Maximum run time at 3/4 load (h) | 4.5 | |
Engine oil capacity (L) | ||
Guaranteed sound power (LWA dB) | 93 dB | |
Generator | Rated Frequency (Hz) | 50 |
Rated AC Voltage (V) | 230 | |
Rated Output Power: (Continuous) (W) | 1700 | |
Maximum Rated Output Power (W) | 1800 | |
Output Type | Modified Sine Wave | |
Rated DC Voltage (V) | 12 | |
Rated DC Current (A) | 5 | |
Rated AC Output Current (A) | 7. | |
Rated Power Factor | 1 | |
Performance Class | G1 | |
Quality Class | A | |
IP Rating | IP23M | |
Dimensions | Length (mm) | 488 |
Width (mm) | 285 | |
Height (mm) | 463 | |
Unpacked Weight (kg) | 19. |
DECLARATION OF CONFORMITY
This is an important document and should be retained.
We hereby declare that this product(s) complies with the following
directive(s): 2014/30/EU Electromagnetic Compatibility Directive. 2006/42/EC
Machinery Directive. 2000/14/EC Noise Emissions Directive, (amended by
2005/88/EC). 2016/1628 Regulation (EU), Emission of Gaseous Particulates (with
amendments). 2011/65/EU Restriction of Hazardous Substances, (amended by
2015/863).
The following standards have been applied to the product(s): EN
55012:2007+A1:2009, EN 61000-6-1:2007, EN ISO 8528-13:2016.
The technical documentation required to demonstrate that the product(s)
meet(s) the requirement(s) of the aforementioned directive(s) has been
compiled and is available for inspection by the relevant enforcement
authorities.
The CE mark was first applied in: 2014
Signed:
DECLARATION OF CONFORMITY
This is an important document and should be retained.
Product Description: 1800W Inverter Generator
Model number(s): IG2000D
Serial/batch Number: 8877116
Date of Issue: 05/05/2021
(Noise Conformity) Notified Body: Intertek Testing & Certification Ltd
Intertek House, Cleeve Road, Leatherhead, Surrey, KT22 7SB UK
Technical Documentation Holder:
Alan Pond Clarke International 2a Shrubland Road London E10 7RB UK
Conformity Assessment Procedure: to 2000/14/EC
Annex VI Manufacturer: Clarke International Noise
Related Value: 1.7 kW
Measured Sound Power Level: 90dB
Guaranteed Sound Power Level: 93dB
| A SELECTION FROM THE VAST RANGE OF
QUALITY PRODUCTS
AIR COMPRESSORS
From DIY to industrial, Plus air tools, spray guns, and accessories.
GENERATORS
Prime duty or emergency standby for business, home and leisure.
POWER WASHERS
Hot and cold, electric and engine driven • we have what you need
WELDERS
Mig, Arc, Tig, and Spot. From DIY to auto/industrial.
METALWORKING
Drills, grinders, and saws for DIY and professional use.
WOODWORKING
Saws, sanders, lathes, mortises and dust extraction.
HYDRAULICS
Cranes, body repair kits, transmission jacks for all types of workshop use.
WATER PUMPS
Submersible, electric, and engine-driven for DIY, agriculture, and industry.
POWER TOOLS
Angle grinders, cordless drill sets, saws and sanders.
STARTERS/CHARGERS
All sizes for car and commercial use.|
---|---|---
PARTS & SERVICE: 0208 988 7400
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
Clarke INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeintemationalcom
Documents / Resources
|
Clarke IG2000D Inverter
Generator
[pdf] Instruction Manual
IG2000D, Inverter Generator, IG2000D Inverter Generator, Generator
---|---
|
Clarke IG2000D Inverter
Generator
[pdf] Instruction Manual
IG2000D, Inverter Generator, IG2000D Inverter Generator
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>