AVM-03AVM-03 Mini Anemometers Operating Instruction
Introduction
is a stable, safe, reliable mini digital anemometer, widely used in mining,
elecbic, iron and steel, petrochemical, energy-saving, navigation, fan
manufacturing, exhaust ventilation, sporting and many more industries.
This operating manual includes relevant safety information and warnings.
Please read this manual carefully and observe all the cautions strictly.
warning:
Before using the product, please read the operation safety rules carefully.
Out of the Box
Open the packing box and take out the meter. Please check carefully if any items below are missing or damaged.
- Main unit——1
- Blister——-1
- Operating manual—1
Operation Safety
-
Please check the meter and the accessories before using and beware of any damage or abnormal phenomenon. If you find the case is damaged or the LCD shows nothing, or you consider that the meter could not work
properly anymore, please stop using it. -
0bserve the operating instructions while measuring.
-
.Do not open the meter at will or change internal wiring to avoid damages to the mater.
-
When the LCD displays “Gil”, replace the battery timely. Remove the battery if the meter is not used for a long time.
-
Do not store or use the meter in high temperature, high humidity, flammable, combustible, or strong electromagnetic environment.
-
Please use soft doth and neutral detergent to clean the case for maintenance. Do not use grinding agent and solvent to avoid case corrosion and damaging the meter.
Warning :
Based on the principle of magnetic induction wind speed measurement, the
product may be subject to interference under strong battery radiation
condition. Please stay from those conditions as far as possible.
Product Outlook
- Vane
- Meter
- LCD display
- Function keys
DISPLAY INTERFACE
- Maximum measurement
- Average value
- Data hold
- Low battery
- mis
- km/h
- ft/min
- Knots
- Mph
- Celsius
- Fahrenheit
- Temperature value
- Wind chill notification
- Wind speed value
- Beaufort scale
Key functions and setup
-
0N/OFF: Short press once to start up; short press again to power off.
Note: Product’s auto power off feature can be disabled: Press and hold “HOLD” and then press “ON/OFF” key to enable/disable auto poYJel'” off, LCD will display “APO OFP to indicate status. -
UNIT: Unit conversion key: Short press this key and the wind speed value cycles mis, km/h, ft/min, knots, and mph. Long press this key and the temperature unit changes between “C and °F.
-
MAX/AVG: Pressing this key can select maximum, average and normal value measurement; select maximum and the meter will always show the maximum reading; select average and the meter will always show the average reading.
-
HOLD/BL: HOLD: Short press this key once to hold the measurement; short press this key again to exit data hold and continue normal measurement.
BL: Long press this key to tum on backlight; long press this key again to tum off backlight.
Technical Specification
-
Wind Speed and Temperature
-
General Type
a. LCD display: 4-bit LCD display. The displayed maximum is 9999.
b. Over1oad indication: When 1he wind speed is ewer 45m/s or the temperature is lower than -1 O”C or higher than 50°C:, “OL” will be displayed.
c. Low battery display: Prompt “Gil•. The new battery should be replaced in time.
d. Sampling rate: 2/s
e. Sensor type: Magnetic induction type wind speed sensor and NTC negative temperature ooefficient sensa”.
f. When the temperature is lower than 0″C and the wind speed is over 5m/s, the meter shows ‘WINDCHILL”.
g. Impact strength: Can withstand the impact of landing from 1 meter’s height.
h. Power requirement: 1.5\/ batteries (MA) x3
i. Product size: 16Qx5Qx28mm
j. Weight: 118g -
Environment Specification
a. Indoor use
b. Altitude height: 2000m
C. Pollution level: 2
d. Wor1<ing temperature and humidity: 0″C-40″C (not greater than 80%RH) 40″C-50″C (not greater than 45%RH)
e. storage temperature and humidity: -20″C-60″C (not greater than 75%RH) -
Electrical Specifications
a. Aro.Jracy: Wind speed: ±5%rdg + 0.5 Temperature: ±2″C
b. Environment temperature: 23″C:!:5″C
c. Environment humidity: :::;ao%RH -
General Maintenance
Warning: please do not open the meter case to avoid affecting device accuracy or damage to the meter.
a. Maintenance and service of the meter should be accomplished by professional personnel or designated maintenance department.
b. Clean the case by dry cloth periodically, detergent with abrasive or solvent composition shall not be used. -
Battery Installation and Replacement
a. The meter uses 3 pieces of MA 1.5\/ batteries. Please see figure below for steps of battery installation and replacement.
b. Tum the panel down, push the battery cover open in 1he direction of the arrow, lift the cover and remove the batteries; install new batteries in accordance of polarity indications.
c. Please use batteries of same type instead of improper
ones.
d. Close the cover tightly after installing new batteries.