ELATEC TWN4 Palon Compact Legic Wall Light User Manual
- June 6, 2024
- ELATEC
Table of Contents
TWN4 PALON COMPACT
LEGIC WALL LIGHT
USER MANUAL
INTRODUCTION
ABOUT THIS MANUAL
This user manual is intended for the user and enables safe and appropriate handling of the product. It gives a general overview, as well as important technical data and safety information about the product. Before using the product, the user should read and understand the content of this user manual.
For the sake of better understanding and readability, this user manual might contain exemplary pictures, drawings, and other illustrations. Depending on your product configuration, these pictures might differ from the actual design of your product.
ELATEC SUPPORT
In case of any technical questions, refer to the ELATEC website
(www.elatec.com) or contact ELATEC technical support
at: support-rfid@elatec.com
In case of questions regarding your product order or if you wish additional
copies of this user manual, contact your Sales representative or ELATEC
customer service at: info-rfid@elatec.com
REVISION HISTORY
VERSION | CHANGE DESCRIPTION | EDITION |
---|---|---|
01 | First edition | 08/2021 |
INTENDED USE
TWN4 Palon Compact Wall Light is a versatile in-wall mount reader for integration into wall flush mount installation boxes. It supports enhanced interfaces, especially RS-485, and inherits all advantages and integrated tool support of the ELATEC TWN4 family. The IP54 protected housing is easy to install. The standard electric frame design elements make a unique look and feel.
The product is for indoor use and may not be used outdoor.
Any use other than the intended use described in this section, as well as any
failure to observe the safety information listed in this document, will be
considered misuse and will void the warranty. ELATEC is not responsible for
any damage or injuries resulting from any misuse of the product.
SAFETY INFORMATION
Installation
-
The installation of the product should be done by trained and qualified personnel only.
Do not install the product by yourself. -
Metallic materials on or in direct vicinity to the product might reduce the reading performance of the product. In some circumstances, plastic screws should be preferred to metallic screws when installing the product. Refer to the installation instructions or integration manual of the product for more information.
Handling
-
Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED).
Avoid direct eye contact with the blinking or steady light of the light- emitting diodes. -
The product has been designed for use under the following conditions:
- Temperature range: -25 °C – 70 °C (operating conditions)
- Relative humidity: 5% – 95% (non-condensing)
- Indoor use – no outdoor use!
Any use of the product under different conditions might damage the product or alter its reading performance.
- The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
- The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELATEC. ELATEC is not responsible for any damage or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC.
- Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids.
Users with a pacemaker or any other medical device should use TWN4 Palon Compact Wall Light carefully and refer to the information given by the manufacturer of their medical devices before using TWN4 Palon Compact Wall Light.
Maintenance and cleaning
-
Any repair or maintenance work should be done by trained and qualified personnel only.
Do not try to repair or carry out any maintenance work on the product by yourself.
Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party. -
The product does not need any special cleaning. However, the housing may be carefully cleaned up with a soft, dry cloth on the outer surface only.
Make sure that the used cloth and cleaning agent do not damage the product or its components (e.g. label(s)).
Disposal
- The product must be disposed of in accordance with the EU directive on waste electrical and electronic equipment (WEEE) or other applicable local regulations.
Product modifications
- The product has been designed, manufactured, and certified as defined by ELATEC.
Any product modifications not expressly approved by ELATEC, including – but not limited to – modifications of antennas or other radio-related components, is not allowed and will void the warranty and all approvals granted to the product.
If you are unsure about any part of the safety information above, contact
ELATEC support.
Any failure to observe the safety information above will be considered misuse
and will void the warranty. ELATEC is not responsible for any damage or
injuries resulting from any misuse of the product.
TECHNICAL DATA
The reader is equipped with the following antennas:
PCB contained in TWN4 Palon Compact Wall Light
HF antenna (13.56 MHz)
Dimensions: 39 x 42.5 mm / 1.54 x 1,67 inch
Number of turns: 3
LF antenna (125 kHz)
Dimensions: 27 x 27.5 mm / 1.06 x 1.08 inch
Number of turns: 179
For more information, refer to the product data-sheet.
MODE OF OPERATION
OPERATING MODE
In order to start operating TWN4 Palon Compact Wall Light, it simply has to be connected directly to a host device.
POWER UP
In case of an external power supply unit is used, the following requirements must be satisfied:
- Limited power source according to the safety norms listed in the respective declaration(s) of conformity
- Short-circuit current < 8 A
Once TWN4 Palon Compact Wall Light is connected to the host, it detects the type of communications cable, with which it is connected to the host.
ENUMERATION
This is only applicable for the USB version: Once the device has been powered up, it is waiting for completion of the enumeration by the USB host. As long as the device is not enumerated, it is entering a minimum power consumption mode, where both LEDs are turned off.
INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on the built-in transponder-reader logic. The green LED is turned on permanently. Some RFID readers need some kind of initialization, which is performed in this step. After successful initialization, the device sounds like a short sequence, which consists of a lower tone followed by a higher tone.
NORMAL OPERATION
As soon as the reader has completed the initialization, it is entering normal operation. During normal operation, the reader is searching for a transponder continuously
DETECTION OF A TRANSPONDER
If a transponder is detected by the reader, the following actions are performed:
- Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard.
- Sound a beep.
- Turn off the green LED.
- Blink the red LED for two seconds.
- Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the
transponder, which just has been recognized will not be accepted again. This
prevents the reader from sending identical IDs more than one time to the host.
If during the two seconds timeout of the red LED a different transponder is
detected, the complete sequence restarts immediately.
SUSPEND MODE
The USB version of the reader supports the USB suspend mode. If the USB host is signaling to suspend via the USB bus, the reader is turning off most of its power-consuming peripherals. During this operation mode, no detection of transponders is possible and all LEDs are turned off. Once the host is resuming to normal operation mode, this is also signaled via the USB bus. Therefore, the reader will resume to normal operation too.
COMPLIANCE STATEMENTS
EU
TWN4 Palon Compact Wall Light is in compliance with the EU directives and regulations as listed in the respective declaration of conformity.
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution
The Federal Communications Commission (FCC) warns the users that changes or
modifications to the unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC §15.105 (b)
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Contains FCC ID: WP5TWN4F10
IC
This device complies with Industry Canada’s license-exempt RSS. Operation is subject to the following two conditions:
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Contains IC: 7948A-TWN4F10
RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices)
This device complies with the RF exposure requirements for mobile and fixed
devices. However, the device shall be used in such a manner that the potential
for human contact during normal operation is minimized.
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM | EXPLANATION |
---|---|
FCC | Federal Communications Commission |
HF | high frequency |
IC | Industry Canada |
LF | low frequency |
NFC | near field communication |
PCB | printed circuit board |
RFID | radio frequency identification |
WEEE | Waste of electrical and electronic equipment. |
Refers to Directive 2011/65/EU of the European Parliament and of the Council of the European Union
B – RELEVANT DOCUMENTATION
ELATEC documentation
- ELATEC quick start guide
- Installation Manual TWN4 Palon Compact Wall kit
- TWN4 Palon Compact Wall Light datasheet
- TWN4 Palon technical handbook
- ELATEC GMBH
Zeppelinstr. 1
82178 Puchheim, Germany
P +49 89 552 9961 0
F +49 89 552 9961 129
E-mail: info-rfid@elatec.com
elatec.com
Elatec reserves the right to change any information or data in this document
without prior notice. Elatec declines all responsibility for the use of this
product with any other specification but the one mentioned above. Any
additional requirement for a specific customer application has to be validated
by the customer himself at his own responsibility. Where application
information is given, it is only advisory and does not form part of the
specification. Disclaimer: All names used in this document are registered
trademarks of their respective owners.
© 2021 ELATEC GmbH – TWN4 Palon Compact Wall Light user manual DocRev1 –
08/2021
References