PN-HY501 Dismantle Instruction
LCD MONITOR
MODEL
PN-HY501
Dismantle Instruction
Scope
This document describes dismantling instruction according to Annex VII of Directive 2012/19/EU.
Tools for dismantling
Below tools are required to dismantle this product.
- Screw Driver
- Nipper
Dismantle Procedure
This product can be dismantled by below steps.
- Remove Back covers (section 4)
- Remove Printed circuit boards (section 5)
- Remove Battery (section 6)
- Dismantle LCD (section 7)
- Remove Electrolyte Capacitors (section 8)
Back covers
Back cover can be removed by a screwdriver.
Printed circuit boards
Battery
This model uses only AAA battery for remote control.
Battery can easily be removed.
LCD Module
– LCD Dismantle procedure
- Remove Rear cover
- Remove PWBs
- Remove the Cables
Capacitors
Electrolyte Capacitors which diameter/height is larger than 25mm are installed
on Power PWB.
These capacitors can be removed by using a nipper to cut the leads.
Parts List
Parts described in Annex VII of directive 2012/19/EU are as below.
Parts | Note |
---|---|
LCD | 50inch LCD module |
Printed Circuit Boards | Main I/F PWB |
Power PWB
T-CON PWB
Battery| AAA battery
Electrolyte capacitors (height >25mm, diameter >25mm)| On Power PWB
External electric cables| 2 kinds of Power Cord