SAFETY INSTRUCTIONS
WARNING! Do not alter or modify your unit in any way. Use only replacement parts authorized by Legend Brands, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized distributor for assistance.
CORRECT PLUG REMOVAL
Grasp IEC plug and pull straight out
IMPORTANT: Damage to the IEC receptacle or dehumidifier resulting from improper removal of the power cord is not covered by warranty. The IEC power cord is a worn item and is not covered by a warranty.
WARNING! Electric shock hazard, rotating fan, hot surface hazards. Unplug the unit before opening the cover for cleaning or servicing. The unit must be grounded.
- Inspect the power cord before use. If the cord is damaged, do not use it. Always grasp the plug (not the cord) to unplug.
- Insert a three-prong plug-on power cord into a match-ing electrically grounded outlet. Do not use an adapter. Never cut off the third prong. Do not use an extension cord.
- The unit must be operated on a 115V/60Hz circuit protected by a Ground Fault Circuit Interrupter (GFCI) device.
- Keep motor and wiring dry.
- Do not attempt to repair the unit. For Authorized Service Centers, contact Dri-Eaz.
NOTICE : Do not use in environments where corro- sive chemicals are present, such as chlorine.
BEFORE YOU BEGIN
Warranty registration
Visit warranty.LegendBrandsRestoration.com to register your purchase.
Registration allows us to better assist you with using, maintaining or
servicing your equipment and to contact you in case we have important safety
information concerning your Dri-Eaz product. If you determine service is
required, have your equipment model, serial number and original proof of
purchase available and call your distributor for assistance with obtaining a
return material authorization (RMA).
INTRODUCTION
The Revolution Dehumidifier reduces humidity in en-closed structural environments by removing water vapor from the air. With proper use, the Revolution can help to dry out damp structural materials, insulation, and con- tents, and maintain a healthy level of humidity. Using the Revolution may also prevent secondary damage caused by high humidity.
How the Revolution works
The Revolution refrigerant dehumidifier uses a fan to draw moist air in and
condenses it into water that collects in a tray and is automatically pumped
out through a drain hose. The unit can be set to operate continuously or the
user may select Humidistat Mode. In Humidistat Mode, the Revolution will turn
on and off automatically to maintain the inlet humidity level the user has
selected.
CONTROLS AND OPERATING INSTRUCTIONS
-
Set unit upright
NOTICE: Always store, transport, and use the unit in a horizontal position. If the unit is ever placed in a vertical position, return it to the horizontal position and let it stand for at least 30 minutes before turning it on. -
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an enclosed area. Close all doors and windows that open to the outside to maximize water removal efficiency. Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the unit. -
Set up drain hose
This unit automatically pumps out water on a regular basis. This dehumidifier is equipped with a quick-connect fitting for attachment to the provided 40 ft. (12 m) drain hose located in the tray on top of the unit. Unwrap the entire hose and place the open end in a sink, drain, bucket, or outdoors – anywhere that water can drain out safely. If you use a bucket or other container for water collection, check it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the hose coiled and do not place the end of the hose higher than 20 ft. (6 m) above the bottom of the unit. Also, check for kinks or other obstructions that might restrict the flow of water. Obstructions may cause a water backup and result in overflows.
110485K (07-01839) F413
Fig. A: Parts Identification
Plugin the electrical cord
The Revolution should be plugged into a GFCI-protected 115 volt outlet rated
for at least 15 amps. Always plug the cord firmly into the unit first, and
then plug the other end into a suitable outlet.
HOW TO USE THE CONTROL PANEL
The i-Series Controller provides comprehensive dehumidifier controls and
detailed real-time data about the drying environment as well as job hours,
self-diagnosis messages, maintenance reminders and operating status.
For detailed information and additional instructions, please visit the
i-Series Controller page at
Controller.LegendBrandsRestoration.com
Home Screen Views
ERRORS AND WARNINGS
If the control system detects a problem, it will display an “Alert” symbol in the upper right corner of the screen. Press ON/OFF to view the message and OK to clear the message. NOTE: In the case of an error, the unit will not operate until the problem is resolved. Refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your local authorized service center for further assistance.
C O N T R O L P A N E L M E S S A G E|
E X P L A N A T I O N A N D S O L U T I O N
---|---
ER4 Error
Defrost Thermistor Connect
—or—
ER4 Error
Outlet Thermistor Connect
|
The temp sensor is open, missing, or shorted. Check that temp sensors are in- stalled correctly on the control panel. If the error persists, contact the service.
ER5 Error
Inlet RH1 Temp/RH Sensor
| Inlet Temp/RH sensor is open, missing, or shorted. Check that the inlet temp/RH sensor is installed correctly on the control panel and inlet shroud. If the error persists, contact the service.
ER5 Error
Inlet RH1 Temp/RH Sensor
| Inlet Temp/RH sensor is open, missing, or shorted. Check that the inlet temp/RH sensor is installed correctly on the control panel and inlet shroud. If the error persists, contact the service.
ER6 Error Current Sensor Failure
|
Current sensor failure. If the error persists, contact the service.
ER9 Error Pump Blocked
|
Check for obstructions in the drain hose. Check the pump.
W1
Low BATTERY
|
Replace the coin cell battery (3V, CR2032) on the control panel.
W2
BLE Error W3
Flash Reset W4
WDT Reset
|
Cycle power to the dehumidifier. If the warning persists, contact the service.
AT THE END OF THE JOB
To reduce the possibility of drips when moving the unit, follow these
additional steps to ensure that all water is removed from the unit.
NOTICE : To ensure all water is removed from the dehumidifier, the unit
will complete the defrost cycle even if the unit is turned off. If the unit is
unplugged during the defrost cycle, excessive water may accumulate in the unit
and may drip out when you move the unit.
NOTICE: To ensure the condensate tank empties completely while purging,
make sure the unit is placed up-right on a horizontal surface.
- Do not turn the unit off or move it until it has returned to normal operating mode.
- Gently rock the machine to ensure any water remaining on interior surfaces falls into the sump area.
- Press the PURGE key. When the purge cycle is complete, turn the unit off.
- Remove the external drain hose, drain it carefully, coil it, and secure it with one of the straps provided.
- Remove the power cord, coil it neatly, and secure it with one of the straps provided.
TRANSPORTATION AND STORAGE
NOTICE: Always remove the power cord before moving, transporting, or
storing the unit.
NOTICE: Handle the unit carefully. Do not drop, throw, or place the unit
where it could fall. Rough treatment can damage this equipment and may create
a hazardous condition or void warranty.
- Do not expose the control panel to moisture, snow, or rain.
- Protect from freezing.
- Store and transport securely to avoid any damaging impact on internal parts.
- Secure during transport to prevent sliding and possible injury to vehicle occupants.
MAINTENANCE SCHEDULE
- WARNING! ELECTRIC SHOCK HAZARD. Unplug the unit before cleaning or servicing.
- WARNING : Risk of dust and contaminants exposure. Use of respirator mask and gloves is recommended. If the unit has been exposed to potentially dangerous contaminants, clean thoroughly and sanitize before reuse.
- NOTICE : The unit is fitted with sensitive electronic sensors. Protect the sensors and their lead wires from damage and do not expose them to water or cleaning solutions.
The following tools and supplies are needed to complete the maintenance procedures described in this manual:
- Philips screwdriver
- 10 mm wrench
- 6 mm hex bit
- ¼ in. nut driver
- Cleaning cloths
- A HEPA vacuum cleaner with a soft brush nozzle and crevice nozzle.
- Recommended
- Cordless drill, small knife, small-jaw pliers, coil cleaning solution, rotomolded housing cleaning solution.
Before each use
Inspect the electrical cord for damage. Look for fraying, cuts, etc. If
you find any damage, replace the cord with an authorized Legend Brands part.
Inspect filter. Replace if the accumulation of dust and debris is
visible.
NOTICE: Replace used filters only with a new Dri-Eaz 4-PRO filter part
no. #102312 (F583) (24-pack). Other filter types do not provide adequate
filtration or airflow. Each filter is individually wrapped to protect
filtration effectiveness. Remove the wrapper before installing the filter into
the dehumidifier.
110485K (07-01839) F413
Fig. B: Disassembly for Cleaning
Monthly
Inspect coils. Clean when dust accumulation is visible. In normal use, dust
can accumulate and can restrict air flow, reducing performance and causing the
unit to overheat. Use a vacuum cleaner with a brush tool and a soft cloth to
remove any debris. Take care not to damage any interior components.
To maintain the appearance, wipe interior and exterior surfaces with a
damp cloth. For deep cleaning and a lasting, protective shine, use an
automotive interior cleaner.
As Needed
Clean pump check valve and basin. Remove grills and cover as shown in
Fig. B. Remove screws from the pump base and lift out the pump. Wipe out the
pump basin with a damp cloth. Inspect the pump base for the build-up of debris
and clean if needed. Unthread barbed fitting with check valve and rinse
fitting and check valve with clean water. Reinstall check valve into barbed
fitting and install the barbed fitting into the pump. Do not overtighten.
Reinstall pump on base. Reinstall cover and grills.
Clean coils. With the cover removed, inspect both coils. If excessive
dust and debris is present, vacuum thoroughly and/or clean with coil cleaner.
TROUBLESHOOTING
F A U L T | C A U S E | S O L U T I ON |
---|---|---|
Water drips out when moving unit | The unit was unplugged before purging was | |
complete. | Purge unit before moving. See “At the End of the Job.” | |
The unit does not operate | Unit not switched on. No power to the machine. |
Switch unit on.
Plug-in unit; check power cord connection at the wall outlet and at the base of the unit.
Unit operating, but room not dry| Not enough time to dry. Poor air movement in the room.
Excessive moist air infiltration.
| Make sure “Humidistat” is OFF. Allow more time for drying. Increase air movement with air movers.
Seal off area to reduce infiltration.
The unit collects too little water| Room air is dry.
The room temperature is too low. Filter is clogged.
Coils are clogged.
| Make sure “Humidistat” is OFF. Confirm humidity level with a hygrometer. Increase room temperature.
Check filter. Replace as necessary. Check coils. Clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact our Service Department toll-free at800-932-3030 for further assistance.
SPECIFICATIONS
Name | Revolution LGR Dehumidifier Model F413 |
---|---|
Dimensions (W × H × D) | 12.5 × 17.6 × 21.5 in. |
31.8 × 44.7 × 54.6 cm
Weight (w/ cord & hose)| 65 lbs. | 29.5 kg
Amps| 6.2 amps at 80°F/60% RH
Power| 115V / 60Hz
Air movement| 121–180 CFM | 3.43–5.1 CMM
Water removal
| 80 pts/day | 38 L/day
at 80°F/60% RH (AHAM)
134 pts/day | 63 L/day at 90°F/90% RH
Operating temperature range| 33–100°F |1–38°C
Safety| ETL listed to CSA standards
Specifications are subject to change without notice. Some values may be
approximate.
WARNING: This product may expose you to chemicals, including lead and phthalates, known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to P65Warnings.ca.gov
PARTS INCLUDED
- 40 ft. (12 m) of drain hose with quick-connect fitting. 25 ft. (7.6 m) detachable power cord.
- 4-PRO Air filter reorder no. #102312 (F583) (24 pk)
OPTIONAL
Duct Attachment Kit #106996 (F530)
ADDITIONAL PRODUCT INFORMATION and current documentation is available at
Revo.LegendBrandsRestoration.com.
FOR PARTS AND SERVICE CALL YOUR LOCAL DIS-TRIBUTOR or Dri-Eaz at
800-932-3030.
LegendBrandsRestoration.com
Visit warranty.LegendBrandsRestoration.com and register your purchase to
ensure you receive any important product releases.