citronic PL720 1U Stereo Power Amplifiers User Manual

June 6, 2024
citronic

citronic PL720 1U Stereo Power Amplifiers

citronic PL720 1U Stereo Power Amplifiers

Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty

Introduction

Thank you for choosing the Citronic PL-series 1U class-D power amplifiers as part of your sound reinforcement system. These high output amplifiers are designed to offer high quality, dependable service for mobile and installed systems. Please read this manual fully and follow the instructions to achieve the best results with your new purchase and to avoid damage through misuse.

Warning
To prevent the risk of fire or electric shock, do not expose any of the components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside – Do not open the case – refer all servicing to qualified service personnel.

Safety

  • Check for correct mains voltage and condition of IEC lead before connecting to power outlet
  • Ensure speaker leads are good condition with no short connections or damaged plugs
  • Check impedance of speaker loads do not exceed the minimum stated load for the amplifier
  • Do not allow any foreign objects to enter the case or through the ventilation grilles

Placement

  • Keep out of direct sunlight and away from heat sources, damp or dusty environments
  • When rack-mounting, ensure adequate support for the base of the amplifier and firm fixings for the front
  • Ensure adequate air-flow and do not cover cooling vents at the front and rear of the amplifier
  • Ensure adequate access to controls and connections

Cleaning

  • Use a soft cloth with a neutral detergent to clean the casing as required
  • Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
  • Do not use strong solvents for cleaning the unit

Front Panelcitronic PL720 1U Stereo Power Amplifiers
1

Rear Panelcitronic PL720 1U Stereo Power Amplifiers
2

  1. Power on/off switch
  2. Cooling vent
  3. Channel A gain control
  4. LED indicators
  5. Channel B gain control
  6. Channel B input
  7. Mode switch
  8. Channel A input
  9. Ground lift switch
  10.  Channel B SPK output
  11. Channel A SPK output
  12.  Channel B 4mm output
  13.  Channel A 4mm output
  14.  Cooling vent
  15.  IEC mains inlet & fuse
  16. Mains voltage selector

Setup
Before operating the PL series amplifier, check the mains supply voltage and move the voltage selector (16) to the correct supply voltage (115 or 230Vac) if necessary, before connecting the IEC inlet (15) to the mains power supply using the power lead supplied (or equivalent).
Ensure that the cooling vents at front and rear (2, 14) are not covered or obstructed in any way with adequate space for airflow through the unit.
The Citronic PL series 1U amplifiers are capable of driving speakers in 3 modes, set by the Mode selector (7)

Stereo mode
Connect Left and Right speakers to Channel A and Channel B outputs via the SPK (10,11) or 4mm binding post connectors (12, 13) For SPK wiring, connect + and – wires to pins 1+ and 1-, for 4mm posts, wire + to red and – to black. Ensure that the combined load on each channel is no lower than 4Ω (for speakers in parallel, 8Ω + 8Ω = 4Ω) Connect line level Left and Right inputs to the CH A and CH B combo inputs via 6.3mm jack or XLR (6, 8)

Parallel mode
Connect the speakers to the speaker outputs as described above but both outputs will only receive a mono signal from the CH A combo input (6) and is controlled by CH A volume control (3)

Bridge mode
Bridge mode is different to the other 2 modes in that it combines both output channels to a single mono output. This mode enables double the power to a single speaker output compared with Stereo or Parallel modes. The difference is that the speaker load must be no lower than 8Ω, whether a single speaker or combined load. Bridge mode can be useful especially when driving a large, high power subwoofer. Connect speaker(s) to the Channel A SPK output or 4mm binding posts.
For SPK wiring, connect the + wire to 1+ and the – wire to 2+. For 4mm binding posts, connect the + wire to CH A+ and the – wire to CH B+.
Note: For reference, this wiring is printed on the rear panel. Incorrect speaker wiring can damage the amplifier! Bridge output receives a mono signal from CH A combo input (6) and is controlled by CH A volume control (3)

Ground Lift
In normal circumstances, the signal Ground connection is connected to the EARTH of the mains supply. This helps to screen out noise and interference caused by RF emissions and nearby equipment. Normally, the Ground Lift slider switch (9) will be set to the “GND” setting, where Ground is linked to EARTH. Occasionally, the mains EARTH can be noisy and, in these circumstances, it may be preferred to isolate the signal Ground from the mains EARTH connection. Moving the Ground Lift slide switch to the left “LIFT” setting disconnects signal Ground from EARTH can help to remove noise generated in the mains EARTH.

Operation

With CH A and CH B volume controls (3, 5) turned fully down (anti-clockwise), switch on the power (1) and the LED POWER indicator will light (4) Playing the input signal into CHA input (and CH B if in stereo mode), gradually increase the CHA and CHB volume controls (only CHA will have an effect in Bridge mode). The amplified signal should be heard through the speakers and the SIG indicators (4) should respond to the audio output. Increase the volume controls to the required level. Alongside the SIG indicators are CLIP indicators, which should only light very briefly on the loudest transients or spikes in the audio. If the CLIP LEDs light for more than a fraction of a second at a time, the volume controls should be turned down or input signal will need to be reduced. Before powering down, turn down the volume controls to avoid loud pops or noises through the speaker.

Specifications

  PL720 PL1080
Power supply 115/230Vac 50/60Hz (IEC)
Fuse T5AL (~230V) T10AL (~115V) T6.3AL (~230V) T12AL (~115V)
Power RMS @ 8Ω 2 x 200W 2 x 300W
Power RMS @ 4Ω 2 x 360W 2 x 540W
Power RMS Bridged @ 8Ω 1 x 720W 1 x 1080W
Input connections Combo jack/XLR balanced (L+R)
Output connections SPK (L+R) + 4mm binding posts (L+R)
Frequency response 20Hz – 20kHz (±0.5dB)
THD +N <0.05%
Damping factor 300
S/N ratio (A weighted) : line 100dB
Slew rate 20V/us
Input impedance 10k Ohms unbalanced, 20k Ohms balanced
Output circuit architecture Class D
Protection Temperature, short circuit, DC, overload
Indicators Power, signal, clip
Controls L+R level, power on/off, bridge/parallel/stereo, ground lift
Dimensions 482 x 180 x 44mm
Weight 2.6kg 2.8kg

Disposal: The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste
at the end of its useful life. The goods must be disposed of according to your local council guidelines.

Errors and omissions excepted. Copyright© 2021.
AVSL Group Ltd. Unit 2-4 Bridgewater Park, Taylor Rd. Manchester. M41 7JQ
AVSL (EUROPE) Ltd, Unit 3D North Point House, North Point Business Park, New Mallow Road, Cork, Ireland.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals