citronic PL720 1U Stereo Power Amplifiers User Manual
- June 6, 2024
- citronic
Table of Contents
citronic PL720 1U Stereo Power Amplifiers
Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty
Introduction
Thank you for choosing the Citronic PL-series 1U class-D power amplifiers as part of your sound reinforcement system. These high output amplifiers are designed to offer high quality, dependable service for mobile and installed systems. Please read this manual fully and follow the instructions to achieve the best results with your new purchase and to avoid damage through misuse.
Warning
To prevent the risk of fire or electric shock, do not expose any of the
components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to
dry out and have checked by qualified personnel before further use. Avoid
impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside – Do not open the case – refer all servicing
to qualified service personnel.
Safety
- Check for correct mains voltage and condition of IEC lead before connecting to power outlet
- Ensure speaker leads are good condition with no short connections or damaged plugs
- Check impedance of speaker loads do not exceed the minimum stated load for the amplifier
- Do not allow any foreign objects to enter the case or through the ventilation grilles
Placement
- Keep out of direct sunlight and away from heat sources, damp or dusty environments
- When rack-mounting, ensure adequate support for the base of the amplifier and firm fixings for the front
- Ensure adequate air-flow and do not cover cooling vents at the front and rear of the amplifier
- Ensure adequate access to controls and connections
Cleaning
- Use a soft cloth with a neutral detergent to clean the casing as required
- Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
- Do not use strong solvents for cleaning the unit
Front Panel
Rear Panel
- Power on/off switch
- Cooling vent
- Channel A gain control
- LED indicators
- Channel B gain control
- Channel B input
- Mode switch
- Channel A input
- Ground lift switch
- Channel B SPK output
- Channel A SPK output
- Channel B 4mm output
- Channel A 4mm output
- Cooling vent
- IEC mains inlet & fuse
- Mains voltage selector
Setup
Before operating the PL series amplifier, check the mains supply voltage and
move the voltage selector (16) to the correct supply voltage (115 or 230Vac)
if necessary, before connecting the IEC inlet (15) to the mains power supply
using the power lead supplied (or equivalent).
Ensure that the cooling vents at front and rear (2, 14) are not covered or
obstructed in any way with adequate space for airflow through the unit.
The Citronic PL series 1U amplifiers are capable of driving speakers in 3
modes, set by the Mode selector (7)
Stereo mode
Connect Left and Right speakers to Channel A and Channel B outputs via the SPK
(10,11) or 4mm binding post connectors (12, 13) For SPK wiring, connect + and
– wires to pins 1+ and 1-, for 4mm posts, wire + to red and – to black. Ensure
that the combined load on each channel is no lower than 4Ω (for speakers in
parallel, 8Ω + 8Ω = 4Ω) Connect line level Left and Right inputs to the CH A
and CH B combo inputs via 6.3mm jack or XLR (6, 8)
Parallel mode
Connect the speakers to the speaker outputs as described above but both
outputs will only receive a mono signal from the CH A combo input (6) and is
controlled by CH A volume control (3)
Bridge mode
Bridge mode is different to the other 2 modes in that it combines both output
channels to a single mono output. This mode enables double the power to a
single speaker output compared with Stereo or Parallel modes. The difference
is that the speaker load must be no lower than 8Ω, whether a single speaker or
combined load. Bridge mode can be useful especially when driving a large, high
power subwoofer. Connect speaker(s) to the Channel A SPK output or 4mm binding
posts.
For SPK wiring, connect the + wire to 1+ and the – wire to 2+. For 4mm binding
posts, connect the + wire to CH A+ and the – wire to CH B+.
Note: For reference, this wiring is printed on the rear panel. Incorrect
speaker wiring can damage the amplifier! Bridge output receives a mono signal
from CH A combo input (6) and is controlled by CH A volume control (3)
Ground Lift
In normal circumstances, the signal Ground connection is connected to the
EARTH of the mains supply. This helps to screen out noise and interference
caused by RF emissions and nearby equipment. Normally, the Ground Lift slider
switch (9) will be set to the “GND” setting, where Ground is linked to EARTH.
Occasionally, the mains EARTH can be noisy and, in these circumstances, it may
be preferred to isolate the signal Ground from the mains EARTH connection.
Moving the Ground Lift slide switch to the left “LIFT” setting disconnects
signal Ground from EARTH can help to remove noise generated in the mains
EARTH.
Operation
With CH A and CH B volume controls (3, 5) turned fully down (anti-clockwise), switch on the power (1) and the LED POWER indicator will light (4) Playing the input signal into CHA input (and CH B if in stereo mode), gradually increase the CHA and CHB volume controls (only CHA will have an effect in Bridge mode). The amplified signal should be heard through the speakers and the SIG indicators (4) should respond to the audio output. Increase the volume controls to the required level. Alongside the SIG indicators are CLIP indicators, which should only light very briefly on the loudest transients or spikes in the audio. If the CLIP LEDs light for more than a fraction of a second at a time, the volume controls should be turned down or input signal will need to be reduced. Before powering down, turn down the volume controls to avoid loud pops or noises through the speaker.
Specifications
PL720 | PL1080 | |
---|---|---|
Power supply | 115/230Vac 50/60Hz (IEC) | |
Fuse | T5AL (~230V) T10AL (~115V) | T6.3AL (~230V) T12AL (~115V) |
Power RMS @ 8Ω | 2 x 200W | 2 x 300W |
Power RMS @ 4Ω | 2 x 360W | 2 x 540W |
Power RMS Bridged @ 8Ω | 1 x 720W | 1 x 1080W |
Input connections | Combo jack/XLR balanced (L+R) | |
Output connections | SPK (L+R) + 4mm binding posts (L+R) | |
Frequency response | 20Hz – 20kHz (±0.5dB) | |
THD +N | <0.05% | |
Damping factor | 300 | |
S/N ratio (A weighted) : line | 100dB | |
Slew rate | 20V/us | |
Input impedance | 10k Ohms unbalanced, 20k Ohms balanced | |
Output circuit architecture | Class D | |
Protection | Temperature, short circuit, DC, overload | |
Indicators | Power, signal, clip | |
Controls | L+R level, power on/off, bridge/parallel/stereo, ground lift | |
Dimensions | 482 x 180 x 44mm | |
Weight | 2.6kg | 2.8kg |
Disposal: The “Crossed Wheelie Bin” symbol on the product means that the
product is classed as Electrical or Electronic equipment and should not be
disposed with other household or commercial waste
at the end of its useful life. The goods must be disposed of according to your
local council guidelines.
Errors and omissions excepted. Copyright© 2021.
AVSL Group Ltd. Unit 2-4 Bridgewater Park, Taylor Rd. Manchester. M41 7JQ
AVSL (EUROPE) Ltd, Unit 3D North Point House, North Point Business Park, New
Mallow Road, Cork, Ireland.
Read User Manual Online (PDF format)