Miele PFD 101 U Brilliant Built Under Dishwasher Installation Guide

June 6, 2024
Miele

**Miele PFD 101 U Brilliant Built Under Dishwasher Installation Guide

**

Installation notes

For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation, the installation diagram, and the operating instructions.

This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on site for the installation of the dishwasher.

Installation requirements

Installation and commissioning work should be performed by a qualified and trained service technician in accordance with local and national safety regulations.
Installation must comply with all local codes and regulations.

Surrounding area

Condensate can build up in the area surrounding the dishwasher. Any cabinetry and fittings in the room must, therefore, be suitable for this purpose.

Vapor-barrier film for built-in appliances

The vapor-barrier film supplied with the dishwasher protects the countertop from damage caused by steam when the door is opened. Attach the vapor-barrier film above the door, underneath the countertop.

Electrical connection

All work on the electrical connection should be carried out by Miele Service, an authorized Miele dealer or a qualified service technician.

Plug connection

The dishwasher should be connected to the electricity supply via an electrical socket outlet.

Hard-wired

If the dishwasher is hard-wired to the power supply, an appropriate circuit breaker for the circuit in compliance with local code must be used.

The electrical socket outlet and the power switch must be accessible after the appliance has been installed. This is to enable any servicing work.
The power cord must be protected from the risk of thermal damage.

Equipotential bonding and grounding

This machine must be grounded in accordance with local code.

Water connection

The dishwasher must only be connected to fully vented pipework.
A brief increase in the water pressure can damage components of the dishwasher.

Water intake

The quality of the incoming water must comply with the requirements for drinking water in the country in which the dishwasher is being operated.

The dishwasher must be connected to the water supply in strict accordance with current local and national water authority regulations. It can be connected to cold or hot water supplies. Connecting the dishwasher to a hot water supply will reduce program cycle times.
For short program cycle times, a water pressure of at least 29 psi (200 kPa) is also required.

If this type of shut-off valve is not available, only a qualified installer may connect the dishwasher to the domestic water supply.

The shut-off valve should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use

Drainage

The dishwasher drainage hose should be connected to a separate on-site drain for the dishwasher only. If no separate drain is available, we recommend connecting it to a dual-chamber siphon. When using a drain loop additional backflow prevention is not required.
If the hose is to be directly connected to the drainage outlet on site, use the hose clip supplied with the dishwasher.

The on-site connector for the drain hose can be used for various hose diameters. If the connector extends more than 1″ (30 mm) into the drain hose, it must be shortened. Otherwise, the drain hose can become clogged.

Lay the drain hose so that it does not kink and is not being subjected to pressure or tugged.

If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a program can cause the appliance to empty itself of water.
In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers.

Appliance dimensions and installation dimensions

Undercounter appliance
Installation Dimensions

Built-in appliance PFD 102 i

Installation Dimensions

Front panel dimensions

Length 19.7″–25.7″ 500–654 mm
Thickness 0.63″–0.79″ 16–20 mm
Weight 8.8–24.3 Ibs 4–11 kg

Fully integrated appliance PFD 104 SCV

Front panel dimensions

Length 27.2″–31.9″ 690–810  mm
Thickness 0.63″–0.79″ 16–20 mm
Weight 11–26.5 lbs 5–12 kg

Connections

Connections on the back of the appliance

Installation Dimensions

On-site connections

  1. Electrical connection
  2. Equipotential bonding and grounding
  3. Waste water
  4. Cold or hot water

Technical details

Dimensions and weights

| | PFD 101 U| PFD 102 i| PFD 104 Vi
---|---|---|---|---
Height| [inches]| 32.| 32.| 33.
[mm]| 805| 805| 845
Height adjustment| [inches]| 3.| 3.| 3.
[mm]| 65| 65| 65
Width| [inches]| 24.| 24.| 24.
[mm]| 598| 598| 598
Depth| [inches]| 22.| 22.| 22.
[mm]| 570| 570| 570
Depth with door open| [inches]| 46.| 46.| 47.
[mm]| 1165| 1165| 1205
Max. toe-kick return| [inches]| 5.| 5.| 5.
[mm]| 115| 115| 115
Weight| [ibs]| 97| 93.| 112
[kg]| 44| 42| 51
Max. floor load| [N]| 1000| 1000| 1000

Emission levels

| | PFD 101 U| PFD 102 i| PFD 104 Vi
---|---|---|---|---
Sound power level| [dB(A) re 1 pW]| 48| 48| 45
Sound pressure level in the workplace| [dB(A)]| 35.1| 35.1| 31.4

Electrical connection
Standard electrical connection

Voltage AC 120 V
Frequency 60 Hz
Fuse rating 15 A
Plug 5–15P NEMA
Power cord length 5.6 ft/1.7 m
Power cord cross-section 3 x AWG14
Heat output 1.3 kW
Total rated load 1.4 kW

Possible voltage variant
PFD 102 i and PFD 104 SCVi only

Voltage 2N AC 208–240 V
Frequency 60 Hz
Fuse rating 2 x 30 A
Plug 14–30P NEMA
Power cord length 5.6 ft/1.7 m
Power cord cross-section 4 x AWG10
Heat output 3.5–3.8 kW
Total rated load Water intake 3.7–4 kW
Max. water temperature 140 °F
Max. water hardness 66.5 mmol/l
Max. water hardness 36 °dH
Water connection pressure 5 – 1000 kPa
On-site threaded connection (flat seal) 3/4″ Hose thread
Connection hose length 4.9 ft
Connection hose extension * 4.9 ft

Drainage

Max. water temperature 180 °F 82 °C
Drain hose length 4.9 ft 1.5 m
Max. drain hose length 13 ft 4 m
Max. drain height 3.3 ft 1 m
Max. transient flow rat                 10 l/min
Hose inner diameter 0.87″ 22 mm
On-site hose sleeve ( x length) 0.87″ x 1.18″ 22 x 30 mm

Operating conditions

Ambient temperature +41 – +104 °F   +5 – +40 °C

Relative humidity:

Up to 88 °F (31 °C), maximum

|  | ****

80 %

|
Linear decreasing to 104 °F (40 °C)|  | 50 %|
Max. altitude above sea level up to| 13,123 ft|  | 4,000 m

Storage and transportation conditions

Ambient temperatur -4 – +140 °F -20 – +60 °C
Relative humidity 10–85 %
Air pressure 500–1060 hPa

Min. site access dimensions including transport pallet

Height 38.2″ 970 mm
Width 26.4″ 670 mm
Depth 26.4″ 670 mm

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>