Operating instructions ****
Malfunction remedy
Malfunction | Possible cause | Remedy |
---|---|---|
Unit is not operating | No mains voltage | Check the mains voltage. |
Water housing is open (safety | Turn the head of the unit clock- | |
Delivery or fountain height | Nozzle blocked | Unscrew and clean the nozzle |
insufficient or not con | insert | |
consistent, | The loss of pressure on the pipe to the watercourse/water feature | |
is too high | Reduce hose length and connect parts to a minimum, route hoses as |
straight as possible
Cloudy water| Intake openings blocked| Clean housing
Filter media clogged| Clean filter media
Impeller unit blocked| Clean the running unit
Pond extremely dirty| Remove algae and leaves from
the pond, change the water
Quartz glass tube soiled| Clean the quartz glass tube
Flow regulator excessively throttled| Set flow regulator
|
The UVC lamp is not lit| The UVC lamp overheats.| After cooling down, the UVC
The temperature monitor turned off the UVC lamp| lamp switches on again auto
matically
The UVC lamp is defective| Replace the UVC lamp.
The UVC lamp is not inserted into the socket properly| Insert the UVC lamp
correctly
into the socket
The unit switches off after a
short running period| Water temperature too high| Observe the maximum water
temperature of +77 °F (+35 °C)