Minoston MR40Z S2 Smart Wall Control User Manual

June 6, 2024
Minoston

Minoston MR40Z S2 Smart Wall Control

Minoston MR40Z S2 Smart Wall Control

Federal Communications Commission (FCC) Statement FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

  • Model:MR40Z
  • Power: 2*CR2032
  • batteries Signal (Frequency): 908.42 MHZ.

Introduction:

This product can be operated in any Z-Wave™ network with other Z-Wave Plus™ certified devices from other manufacturers.
All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
MR40Z is a security-enabled Z-Wave Plus™ device. Security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product. The Device Type of the MR40Z is PORTABLE REMOTE CONTROLLER
The Role Type of the MR40Z is Reporting Sleeping Slave Role Type.

Product Overview

  • A. Up Push button
  • B. Down Push button
  • C. Left Push button
  • D. Right Push button
  • E. LED indicator

Key function description

Function 1 : Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 2: quickly press 6x upper paddle: ADD (inclusion) (only if switch is not included in network)
Function 3: quickly press 6x lower paddle: Remove (exclusion)
Function 4: quickly press 7x upper paddle: Wake up
Function 5: tap-tap-tap and hold to reset, LED indicator will blink red 5 times to confirm a successful reset
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.)

Adding Your Device To A Hub

The device support two methods of inclusion,When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart, Network Wide Inclusion To A Z-Wave™ Network

  1. Refer to your primary controller instructions to process the inclusion/exclusion setup procedure.
  2. When prompted by your primary controller, click the Up or Down button six times in one second.

The device is compatible with SmartStart SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.

QR CODE

the QR code are stuck to the side of the case, DSK is included in the QR code. DSK The DSK code can be found on the DSK label which is attached on the packaging box.

Command Class

You may use the below configuration parameters to change settings of the corresponding functionality.

  1. LED Indicator Mode
    Paramter No: 1 (0x01) Size:1 Byte (default=1)
    Value: 00 LED always off
    Value: 01 LED normal mode
    Value: 02 LED always on in color specified in Parameter 2
    Value: 03 LED always on in color specified in Parameter 3

  2. LED Indicator Color for Upper paddle remote control (Scene 1 activation)
    Paramter No: 2( 0x02) Size:1 Byte (default=1)
    Value: 00 White
    Value: 01 Blue
    Value: 02 Green
    Value: 03 Red
    Value: 04 Magenta
    Value: 05 Yellow
    Value: 06 Cyan

  3. LED Indicator Color for Lower paddle remote control (Scene 2 activation)
    Paramter No: 3 (0x03), Size=1 Byte (default=0)
    Value: 00 White
    Value: 01 Blue
    Value: 02 Green
    Value: 03 Red
    Value: 04 Magenta
    Value: 05 Yellow
    Value: 06 Cyan

Support for Association Groups
MR40Z supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s Association group_1:Z-Wave Plus™ Lifeline  Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MR40Z Status change report, Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MR40Z Status change report,  (ex.Battery Report/Central Scene Notification/ Device Reset Locally Notification/Indicator Report)

Association group_2:BASIC SET

  1. Up button press 1x send basic set 0xff
  2. Down button press 1x send basic 0x00 Association group_3:SWITCH_MULTILEVEL_CHANGE

Association group_3:SWITCH_MULTILEVEL_CHANGE

  1. Up/Down button hold more than 0.5s send SWITCH_MULTILEVEL_START_LEVEL_CHANGE(Dim Up/Dim Down)
  2. Up/Down button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE

Restoring Factory Defaults

MR40Z is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Manual Reset:tap-tap-tap and hold to reset, LED indicator will blink red 5 times to confirm successful reset
Remark: All the settings and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Minoston User Manuals

Related Manuals