ChannelPlus H47XL Series 2
Installation Instructions
Four-Channel Central Heating and
Hot Water Programmer
The H47XL programmers offer the equivalent of four independent seven-day
timers in one modern, good-looking enclosure.
Each of the four channels offers up to three programmed operating periods per
day for each of the seven days of the week, with a boost and advance available
on each.
The fully graphical back-lit display combined with menu-driven programming is
designed to simplify the day to day operation of
the H47XL.
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED
PERSON AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IET WIRING
REGULATIONS.
WARNING: ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
Fitting The Backplate
Once the Backplate has been removed from the packaging, please ensure the
programmer is re-sealed to prevent damage from dust, debris etc.
The Backplate should be fitted with the wiring terminals located at the top
and in a position that allows the relevant clearances around the programmer.
(See diagram)
Direct Wall Mounting
Offer the plate to the wall in the position where the programmer is to be
mounted, remembering that the Backplate fits to the right-hand end of the
programmer.
Mark the fixing position through the slots in the Backplate (Fixing centers
60.3 mm), drill and plug the wall, then secure the plate in position. The
slots in the Backplate will compensate for any misalignment of the fixings.
Wiring Box Mounting
The Backplate may be fitted directly onto a single gang steel flush wiring box
complying with BS4662, using two M3.5 screws.
The ChannelPlus series 2 programmers are suitable for mounting on a flat
surface only, they must not be positioned on a surface-mounted wall box or on
unearthed metal surfaces.
Electrical Connections
All necessary electrical connections should now be made. Flush wiring can
enter from the rear through the aperture in the Backplate. Surface wiring can
only enter from beneath the programmer and must be securely clamped.
The main supply terminals are intended to be connected to the supply by means
of fixed wiring.
The recommended cable sizes are either 1.0 mm2 or 1.5 mm2
ChannelPlus programmers are double insulated and do not require an Earth
connection but an Earth terminal is provided on the Backplate for terminating
any cable Earth conductors. Earth continuity must be maintained and all bare
Earth conductors must be sleeved. Ensure that no conductors are left
protruding outside the central space enclosed by the Backplate.
When used to control MAINS VOLTAGE SYSTEMS terminals L, 2, and 5 should be
electrically linked by means of a suitable piece of the sleeved conductor.
When used to control EXTRA LOW VOLTAGE SYSTEMS, these links MUST NOT be
fitted.
An example circuit diagram is shown on the next page. This diagram is
schematic and should be used as a guide only.
Please ensure that all installations comply with the current IET regulations.
New Installations
Please ensure that all installations comply with the current IET regulations.
For reasons of space and clarity, the diagram has been simplified, for
instance, some Earth connections have been omitted. Other control components
shown in the diagram i.e. Valves, RoomStats etc are general representations
only. However, the wiring details can be applied to the corresponding models
of most manufacturers.
Cylinders and Room Thermostat key:
C = Common
CALL= Call for heat or break
SAT = Satisfied on rise N = Neutral
New Installations
ChannelPlus H47XL Series 2 shown controlling 4 x two-port spring return zone valves via Room Stat and Cylinder Stat giving independent control of Hot water and three zones of Heating.
NOTE: If the ChannelPlus H47XL Series 2 is being installed on an existing system, additional equipment such as extra zone valves will have to be fitted in order to achieve full four-channel control.
Commissioning The Programmer
Ensure all dust and debris has been cleared away from the work area before
removing the programmer from its packaging.
All ChannelPlus controls are fitted with a battery reserve which maintains
programmed times in the event of mains power failure.
Rear View of Channelplus XL Programmer
- RETAINING SCREWS
- CONNECTOR BLADES
- PRODUCTION DATE LABEL
- POSITIONING LUGS
- RATING LABEL
Fitting The Programmer
If surface wiring has been used remove the knockout/insert from the bottom of
the programmer to accommodate it. Loosen the two ‘captive’ retaining screws on
the top of the unit. Now fit the programmer to the Backplate, line the lugs on
the programmer with the flanges on the Backplate.
Swing the top of the programmer into position ensures that the connection
blades on the back of the unit locate into the terminal slots in the
Backplate. Tighten the two ‘captive’ retaining screws to fix the unit
securely, then switch on the mains supply.
Initial Setup
Once the mains power has been switched on the ChannelPlus H47XL Series 2, the
display will illuminate. The programmer has a number of pre-programmed
functions to assist the initial set-up, which are detailed below;
Time and Date – The programmer has been pre-set with the current time and date
during manufacture. No alteration should be required to the time and date,
however, if any modification is required, please refer to the ‘Adjusting Time
and Date’ section of the user guide.
Program Times – The programmer has been pre-set with default heating and hot
water times, these can be altered to meet the user requirements, please refer
to the ‘Setting the Programme Times’ section of the user guide.
PLEASE ENSURE THAT THE USER GUIDE IS HANDED OVER TO THE END-USER.
General Information
Battery
The programmer is fitted with a non-rechargeable, non-serviceable long-life
battery, which will maintain the programmed time settings with the mains
supply disconnected.
THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE
OF THE UNIT.
During power interruptions, the display will be blank.
Service and Repair
This programmer is NOT user-serviceable. Please do not dismantle the unit. In the event of a fault developing, please refer to the RESETTING THE PROGRAMMER section below. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician.
Resetting the ChannelPlus H47XL Series 2
Electronic equipment can in some circumstances be affected by electrical
interference. If the display becomes frozen or scrambled, or if you wish to
revert back to the default settings please use the following procedure.
Reset Procedure
PLEASE NOTE: Using this procedure will restore the ChannelPlus to the original
factory program settings. The time setting will remain correct.
Lower the front flap of the unit. On the far right (forth) Channel press the ADVANCE (Enter) and SELECT (Blue) buttons together then release the buttons and the programmer will return to the preset factory settings.
Specification Channelplus H47XL
Electrical
Purpose of Control| Electronic Central Heating Programmer (4 Channel)
Contact Rating| 3(1) Amp 230V AC
Contact Type| Micro-disconnection
Supply| 230V AC 50Hz only
Protection| Class II
Control Action| Type 1B,R
Operating Time Limitation| Intermittent
Software Class| Class A
Battery Type| Lithium
Battery Life| 10 months continuous operation (minimum)
Display| Full Graphical LCD, Backlit
Clock| 24 Hour / 12 hour AM/PM
Display Time Adjustment| 1 Minute Intervals
Switch Time Adjustment| 10 Minute Steps
Program Selection| Auto, On, All Day, On Constant, Off, Holiday
Operating Periods per Day| 3 for each Channel Independently
Override| Boost 1 or 2 Hours (If pressed during
Mechanical
Dimensions| 163mm x 101mm x 37mm
Case Material| Thermoplastic, flame retardant
Ball Pressure Test Temperature| 75 C
Mounting| Industry-standard 9 pin British Gas
Wallplate independently mounted
Environmental
Impulse Voltage Rating| Cat II 2500V
Enclosure protection| P30
Pollution Degree| Degree 2
Operating Temperature Range| 0 C to +40 C
Compliance
Design Standard| EN 60730-2-7, BS EN 60730-2-7
RoHS
Secure Meters (UK) Ltd
Secure House, Lulworth Close,
Chandler’s Ford,
Eastleigh, SO53 3TL, UK
t: +44 1962 840048
f: +44 1962 841046
www.securemeters.com
Part Number P82733 Issue Number 6