SECURE AD-Infinix Massage Chair User Manual

June 6, 2024
SECURE

SECURE AD-Infinix Massage Chair

Function Introduction

  1. The patented backrest is designed to reduce noise as the massage system delivers a life like soothing kneading, rocking, knocking, tapping, shiatsu and rolling massage.
  2. The computer body scan automatically scans the body, measuring where the top of the neck is located to ensure a complete and accurate massage.
  3. Press the zero gravity button and the chair will recline back, raising the legs and steepening the pitch of the seat base, ultimately putting the user in an optimal stress reduced position.
  4. Even in the most limited of spaces, the lnfinix massage chair is equipped with space saving technology. When the chair reclines, the base will move forward to reduce the amounts of space required to house the chair. The total space needed from the wall to bacrkrest is 5 inches.
  5. Located at the bottom of the feat along the bridge are rollers that spin. The nodes on the rollers will emulate fingers digging into the middle area of the feet, loosening the ligaments and muscles.
  6. Calf spinning massager are placed on the mid-section of the legrest. When activated the circular discs will rotate kneading the back of the calves.
  7. Airbag massager are located all throughout the massage chair where airbags inflate and decompress on the arms, legs, shoulders and feet. The squeezing action will massage the muscles promoting better blood circulations.
  8. The Legrest can be extended and retracted within a range of 8.6 inches, suitable for a variety of different heights. This chair will fit comfortably from 4’10” to 6’3″.
  9. With a quick control panel on the armrest it easy and fast to start a preset programmed massage.
  10. Enjoy the high quality bluetooth speakers by syncing your bluetooth device to the chair. Listen to your favorite tunes while enhancing your massage experience.
  11. Located in the lower lumbar area are 2 heating pads that give a warm heat to help loosen the muscle as it gets massaged.
  12. This chair is designed for the times were we are so dependent on our devices. The lnfinix massage chair has a USS charging port located on the armrest.

Safety Instructions

  • Please read this manual carefully to make sure the installation and operation of the massage chair is being used correctly. “Safety Instructions” are provided in both Warning and Caution “icons” for important safety information.
  • The “warning” and “caution” should be fully observed and followed as instructed
    Warning : This sign indicates warnings of potential death or serious injury.
    Caution : This sign indicates caution of potential bodily injury or damage to the chair.

Warning

  • People with osteoporosis, vertebral fractures, sprains or muscle strains must consult with your medical doctor before using to avoid serious injury.
  • Cancer patients must consult with their with their medical doctor before using.
  • People with perceptual disorders or diabetes must consult their medical doctor before using.
  • People with abnormal spine or scoliosis must consult their doctor
  • People with bulging discs or any disc issues must consult with their doctor.
  • Pregnant women and those who have recently had childbirth must consult with their doctor before using
  • If you have any various skin disease or inflammation must consult their doctor before using.
  • Any one that may not be able to discern the surrounding temperature must have supervision.
  • If you have fever or any illness you must consult with your doctor before using.
  • If elderly in poor health or above 80 years of age must consult with their doctor.
  • Anyone with any handicap or mental disability must consult with their doctor before using. A capable adult that can supervise must attend at all times.
  • If you are impaired by alcohol or any other substance do not use this device.
  • If this chair is wet in any way or you are wet do not use this chair.
  • Do not children under the age of 16 use this chair.
  • Do not fall asleep in this unit and no external articles such as blankets or pillows are permitted to avoid injury. People with above symptoms should not use mas.sage chair, or use it under doctor’s advice. User’s discretion is advised when use the chair.
  • Before sitting, please confirm that there are no foreign objects obstructing the function of the chair.
  • Before operating the chair be sure to check that there are no people, pets or objects in or around the area (behind, under, sides or in front of the chair).
  • In the event if physical pain or irritation is experienced, immediately stop using and consult your doctor.
  • If the massage rollers are massaging the head adjust the starting position of the massage to start on the neck area avoiding the head which may lead to injury.
  • Avoid excessive neck massage which may cause bruising or soreness.
  • Do not massage the ab domen or knees with this machine. Accident/injury
  • If you want to leave your seat during the massage, you must stop the massage chair wait for the chair to be in the full upright position before getting out.
  • Do not use it with other instruments.
  • Do not allow children or pets to play on or around the unit (especially when in use); nor can they sit or stand on backrests, armrests or leg rest
  • Periodically inspect the backrest to ensure the lining is in good condition without any tears.
  • Before moving the unit, the backrest and legrest must be in the default fully upright position.
  • When assembling, make sure there is No power running in chair.
  • Insert the plug of the chair into correct power rated power outlet. Make sure the plug is completely inserted into the socket t o Fire and electric reduce short circuit or fire risk. shock
  • Unplug the power when not in use, stop all massage functions and turn off the power switch and unplugging the chair from the outlet.
  • Do NOT fold the pads & cushions when placing them in storage.
  • Do not let this chair operate for more than a couple of hours Upholstery & consecutively to avoid overheating. Not intended for commercial Overheating use.
  • If the power cord is damaged in any way do not use the chair and proceed to unplug from the power outlet.
  • Don’t use other electric power except rated voltage to avoid fire, electric shock or any breakdown. Fire and electric
  • Any b roken, re-processed, knotted, twisted power cord or pressed shock under heavy cargo is not permitted to be used.
  • Never operate this chair if it has a damaged cord or plug, if it is not working.
  • Keep the power line away from stove or other heat sources.
  • If the chair is not working properly or has been in contact with any liquids do not use the chair and contact the manufacturer for technical support
  • Self-modification, disassembly or maintenance is forbidden . If the power cord or plug is damaged, please don’t replace it yourself, please contact us or an appointed dealer for replacement.
  • To avoid electric shock or bodily harm, please don’t open or disassemble any part of the chair. If the chair is found to be opened or tampered by the customer it will void all warranties.
  • Check upholstery periodically on the backrest and other areas to make sure there are no tears or worn-out areas before using. if any damage is found unplug the chair and contact your local dealer.

Grounding instructions
The chair provides a power cord that has a ground. Do not us any other power cable unless advised by the manufacturer.

Repair Fuse

When the fuse is burned out, please turn off the switch and unplug the power. Opening the lid covering the fuse which is located by the switch box. Using a same size fuse to replace the old one, then cover with the cap. If you do not have a fuse please contact the manfacturer.

Keep this chair clear from any gas lines, telephone lines, water lines and electrical cables. If not followed it may lead to explosions, fires and electrical shock, injury or even death.

External StructureSECURE AD-Infinix Massage Chair fig
2 SECURE AD-Infinix Massage Chair fig 3

Internal StructureSECURE AD-Infinix Massage Chair fig
4

Explosion Diagram

SECURE AD-Infinix Massage Chair fig 5

NO.

|

Name

|

Q’ty

|

NO.

|

Name

|

Q’ty

---|---|---|---|---|---

1

|

Rem ote co ntr ol

|

1

|

22

|

Back seat cushion

| 1
2| Right armrest assembly| 1| 23| Pillow| 1
3|

Right side fender

| 1| | |
4| Footrest electric actuator| 1| | |
5| Solenoid valve assembly| 1| | |
6| Leg support plate| 1| | |
7| Power case assembly| 1| | |
8| Back electric actuator| 1| | |
9| Front swing assembly| 1| | |
10| Bo ttom frame assembly| 1| | |

11

|

Back swing assembly

| 1| | |
12| Left Side fender Assemb ly| 1| | |
13| Po w e r case assembly| 1| | |
14| Front fender assembly| 1| | |
15| Foo t and leg assemb ly| 1| | |
16| Le ft am res t asse mbly| 1| | |
17| Shoulder Assembly| 1| | |
18| Back cover assembly| 1| | |
19| Back cover| 1| | |
20| Massage mechanism| 1| | |
21| Back frame assembly| 1| | |

Installation

Step 1. Take out the main body and accessories from the carton box.

  1. (First take out the accessory box and the legrest.
  2. Use 2 or more people to remove the main body of the massage chair from the box.
  3. Confirm all the accessories are accounted for.
    When removing the legrest from the box be sure to firmly grab it with 2 hands and slide it out of the box and unwrap.SECURE AD-Infinix Massage Chair fig
6

Step2. Placing the Remote in the holder
located on side panel you will find the remote holder bag stitched by the arm massager. Remove the packaging, flip to the outer wall and insert the remote.SECURE AD-Infinix Massage Chair fig 7

Check environment
Make sure when placing the chair there is enough space when chair is reclined.SECURE AD-Infinix Massage Chair fig 8
Because the chair is heavy, it may ruin your floor in long time setting. Please put a blanket or other soft things to protect your floor.

Caution

  • Don’t use the chair near wet or humid places like swimming pool , bathroom, saunas and heating/cooling vents to avoid electric shock and/or injury.
  • The chair must be placed flat, leveled surfaces to avoid damage and injury. Do not place this chair near a window or any place where it will make contact with sunlight that can cause fading and damage to the upholstery.

Step 3. Mounting the Leg-rest

  • Place the leg rest in front for front of the base of the chair.
  • Match the air hose from the leg rest to the base. Then proceed to connect the electrical plug into the base.
  • Raise the leg rest with both hands, push the shaft of leg rest to the limit level pin
  • hanger. Then thread the bolt to connect the leg rest and use the split pin to lock-in. Connect the top flap of the leg rest to the base of the chair using the velcro stitched on both ends.
    Note : The shaft must be securely attached, otherwise it will fall off. When inserting the air pipe and wiring harness, do not wrap the air pipe and wiring harness together. SECURE AD-Infinix Massage Chair fig
9

Step 4. After assembling.

  1. Plug the cable line in the hole a on the power box as shown in the right picture.
  2. Insert the plug of cable line into the socket.
  3. Tum on the switch behind the power box. (Switch on/off “0/1”, press I down to tum it on.)
  4. Press the on button on the remote, select a preset program massage and enjoy!
    Make sure the switch is off before you insert the plug of cable line into the power socket.

The Adjustment before massage

  • Check places in front
    Check the surrounding areas to make sure there is nothing around to avoid injury or damage to the chair.

  • Check power cable, plug

1. Using a clean cloth be sure the power cable is clean without damage.
2. No damage to the cable is a must. If damage to the cable is seen turn off the chair, unplug and contact customer service.![SECURE AD-Infinix Massage Chair fig 12](https://manuals.plus/wp-content/uploads/2022/03/SECURE-AD-Infinix-Massage-Chair-fig-12.jpg)
  • Space to use the chair
    • The chair must be at least 3 inches from the Wc!II to recline.SECURE AD-Infinix Massage Chair fig 13
    • At least 15 inches are needed infront·of·’
    • the legrest to extend.
  • Check surroundings
    When the backrest or legrest reclines or extends, please pay attention to:
1. Check for any person, pets or things in every direction before using.
2. Check the there is substantial space to use the chair.![SECURE AD-Infinix Massage Chair fig 14](https://manuals.plus/wp-content/uploads/2022/03/SECURE-AD-Infinix-Massage-Chair-fig-14.jpg)![SECURE AD-Infinix Massage Chair fig 15](https://manuals.plus/wp-content/uploads/2022/03/SECURE-AD-Infinix-Massage-Chair-fig-15.jpg)

How to move massage chair

Caution : Don’t move chair when it’s working in case of accidents or damage.

How to move

  • Bind the cables and put them in the seat to avoid damage when moving.
  • If you bump or drop the chair, it may damage the inner parts of the chair.
  • Don’t use the castor if the floor is wooden or any other soft materials. It will damage your floors. It will need 2 or more persons to lift the chair when moving.
  • Make sure the power is off and the plug is completely removed from the chair to avoid tripping or damage to the cable.

Normally

  • Press down the head part of the backrest to tilt back on the castors. Then push the chair to desired destination steadily and set it down slowly.

Be sure the leg rest in the full down position before attempting to move. It is even advised to remove the legrest when moving long distances.

Adjustment Before adjustment

  • Before starting the massage the rollers should be at the top of the backrest.
  • When at the top gently sit in the chair to avoid injury.SECURE AD-Infinix Massage Chair fig 17
  • When chair conducts the body scan and is unable to detect where the shoulder and neck is, the massage will start at the highest default position.
  • Right position: When getting body scan be sure that your back and shoulders are firmly pressed against the backrest so that computer can scan your back precisely. Once the scan is complete it will beep. At that time you have to option to adjust the starting point by moving up or down/up button. You have 5 sec to make the adjustment as it beeps to make the adjustment.

Kind suggestion

  • If you feel the massage isn’t strong enough, you can remove the pillow pad on the backrest.
  • Because the chair is heavy, it may ruin your floor. Please put a mat or rug under the chair. This will also make the chair quieter during operations.

Manual Control

SECURE AD-Infinix Massage Chair fig
19

SECURE AD-Infinix Massage Chair fig 20 SECURE
AD-Infinix Massage Chair fig 21

LCD display Graphic Description

After power on, if you press the “on/off “button.the buzzer will ring with a short and crisp sound. The LCD displays the main menu interface and enters the standby state. The Main screen displays information such as auto manual airbag roller, heating, timing setting, stop current working state.etc. That information will be updated in real time after the operation.

Under the main interface of the menu displayed on the LCD screen. press the “Menu” button to enter the massage state interface and then press the “Menu” button to return to the main interface of the menu.

Massage function

  • Kneading
  • Tapping
  • Knocking
  • Shiatsu
  • zero gravity
  • Massage

Manual Massage: On the main interface of the menu, select manual massage through the navigation key. After pressing the “OK” key, there are four functional options: mode, position, width and speed; After selecting the corresponding function, press “OK” to enter the next menu, and select the desired massage mode: kneading, tapping, knocking, kneading and tapping, shiatsu; Massage position include whole, partial and point; Massage width and speed.

Airbag : In the main menu interface, use the navigation keys to Airbag select “Airbag”, after pressing the [OK] key, there are two air  pressure function options: position and intensity. After selecting
menu and select the desired massage parts: the corresponding function, press the [OK] key to enter the next body, legs and feet; massage intensity: 5 levels of display

Foot Roller: In the main interface of the menu, use the navigation keys to select Roller. After pressing the [OK] key, you can choose quick, soft and stop.

Heating : In the main interface of the menu, use the navigation keys to select Heating. After pressing the [OK] key, you can choose to tum on or turn off waist heating.

Timer : In the main interface of the menu, use the navigation keys to select Timer. After pressing the [OK] key, you can choose massage time to 10 mins, 20mins or 30 mins. The default tim e is 20 mins, the massage chair will turn off automatically when the time is up.Settings

Settings : ln the main interface of the menu, use the navigation keys to select Settings. After pressing the [OK] key, you can choose the, desired language

Stop : In the main interface of the menu, use the navigation keys to select Stop. After pressing the [OK] key, the massage chair stop massaging, and heating tum off. Press Menu key again, to go back to main interface.

When power on, the first time you use the auto program, massage chair will start the body scan and “body scanning … ” will be shown on screen. After the body scan is finished, the
buzzer will tick (once every second). At this point, the massage rollers are in the shoulder position, you can press Up and Down to adjust. When adjusting, “shoulder height adjusting ” will be displayed on the screen. The default working time is 20 minutes. The massage chair will turn off and reset to its upright position once the massage is over.

How to Use Simple Control
  1. Press on/off key to turn on or turn off the chair.
  2. In on status, press the Auto to enter three auto programs: Recover, Relief , Stretch .
  3. In on status , press this button , massage chair will go to Zero-gravity position, press it again to return to the original position.
  4. Keep pressing this button for seconds, backrest goes up and legrest goes down. Release this button, backrest and legrest stops moving, the angle is locked in this position.
  5. Keep pressing this button for seconds, backrest goes down and legrest goes up. Release this button, backrest and legrest stops moving, the angle is locked in this position.

FAQ and TroubleShooting

Trouble Possible reason Troubleshoot i ng





The massage chair can’t work after power is on.

| Check if the control is on or not.| Open control switch
Not choose massage function| Choose massage function
Check whether the plug and socket in poor contact.| Make sure plug and socket are comecled.


Wire or plug has damaged.

| Please ask manufacturer or appointed orauthorized maintenance man for checking and replacemert.
The fuse burned out.| Replace fuse of same specification.


Something wrongwithinner cirruit

| Please ask appointed or authorized maintenance man for checking and repairing.
There is beep sound inside themassager while working.| It is sound of air pump, motor and mechanical parts.| Normal sound, no need to pay attention to it.
Different height of the left roller and right roller.| Massage rollers work on shifts.| Normal, no need topay attention toit



Sound suddenly becomes muchlouder while IM’.lrking .

| ****

Check if it is due to long time working.

| Turn off the power to have the massager rest for over half an hour before next turn working.
Inner parts fretted away due to long time work. It’s normal| Please ask appointed or authorized maintenanceman for checking and repairing.


Massage function suddenly

stops while working.

| Suddenly power-down| Connect the electricity power again


Setting time is up.

| Turn off the power to have the massager rest for over half an hour before next turn working.


Neither the backrest nor the legrest can be lay down.

| Check if there are any obstad es; the chair overloads; for the sake of safety, sometimes the massage machine may automatically stop working.| Remove the obstacles; turn off the power to have the massager rest for over half an hour before next turn working.
The chair can’t return to its original position.| ****

Excessive operation; setting time is up.

| Please ask manufacturer or appointed or authorized maintenance man for checking and replacement.



Electric wire or plug give out heat

| ****

It may work overload

| Turn off the power to have the massager rest for over half an hour before next round working.


Other abnormal case

| Stop using, and ask appointed maintenance man for help.

Technical Data:


Name

| ****

Massage Chair

| ****

Power

| ****

180W

|
---|---|---|---|---


Model

| ****

AD-lnfinix

| ****

NW/GW

| ****

841100.5kg

|


Input voltage

| ****

120V- 60Hz

|



Packingsize

| ****

1160 x 77 Qx 1 2 6 5 m m ( L X W X H)

|


Safety design

| ****

Class I

|

Note : If the troubles are not caused by above reasons, please turn off the power switch and cut off the power, then contact the manufacturer or service agent to repair your chair.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SECURE User Manuals

Related Manuals