Control4 8-Channel 0-10V Dimmer-C4-DIN-8TV-E Steiners Audio Video
Supported Model
C4-TV120277 0-10V Dimmer
Introduction
The Control4® 0-10V Dimmer operates independently or as part of a Control4
home automation system. It installs in a standard back box using typical
wiring standards and communicates to the Control4 system using a wireless
connection.
Box contents
- 0-10V Dimmer
- Wire nuts
- Warranty card
- 0-10V Dimmer Installation Guide (this document)
Specifications and supported load types
The specifications are described below.
Model number | C4-TV120277-xx |
---|---|
Power requirements | 120-277VAC +/-10%, 50/60Hz |
This device requires a neutral AC connection. See “Sample Wiring Configurations” later in this guide.
Power consumption| 120V: 485 mW
277V: 1.18 W
Load types and ratings
Supported load types| Four-wire 0-10V and 1-10V dimmable fluorescent ballasts
and LEDs, sink or source.
Maximum load (switched hot)| 120V: 15A
277V: 8A
Maximum load (0-10V
Control)
| 100mA sink or source
Environmental
Operational temperature| 32˚ F – 104˚ F (0˚ C – 40˚ C)
All load ratings are based on an ambient temperature of 25˚ C
Humidity| 5% to 95% non-condensing
Storage| -4˚F ~ 158˚F (-20˚C ~ 70˚C)
Miscellaneous
Control communications| ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel spread
spectrum radio
Wallbox volume| 5.75 cubic inches
Weight| 0.12 lb. (0.05 kg)
Shipping weight| 0.18 lb. (0.08 kg)
Warnings and considerations
WARNING! Turn OFF electrical power before installing or servicing this product. Improper use or installation can cause SERIOUS INJURY, DEATH or LOSS/DAMAGE OF PROPERTY.
WARNING! This device must be protected by a circuit breaker (20A max).
ATTENTION! Cet appareil doit être protégé par un disjoncteur (20A max.)
WARNING! Ground this device in accordance with the National Electric Code
(NEC) requirements. DO NOT rely solely upon the yoke plate’s contact with a
metal wallbox for adequate grounding. Use the device’s ground wire to make a
secure connection to the safety ground of the electrical system.
IMPORTANT! This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
IMPORTANT! If you are unsure about any part of these instructions,
consult a qualified electrician.
IMPORTANT! Use this device only with copper or copper-clad wire. Do not
use aluminum wiring. This product has not been approved for use with aluminum
wiring.
IMPORTANT! To reduce the risk of overheating and possible damage to other
equipment, do not install to control a receptacle or a motor- operated
appliance.
IMPORTANT! Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any damage
incurred with the misuse of this product. See “Troubleshooting.”
IMPORTANT! Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening the
screws may interfere with proper button operation.
IMPORTANT! This is an electronic device with intricate components. Handle
and install with care!
IMPORTANT! When used in conjunction with an Auxiliary Keypad (C4-KA-xx),
the wire connecting the Auxiliary Keypad to the dimmer must not exceed 150
feet (45 m) at 120VAC, and 100 feet (30 m) at 277VAC.
Installation instructions
Ensure that the location and intended use meet the following criteria:
- Do not exceed the load capacity requirements of the dimmer. Refer to the load ratings in the specifications above for details.
- Install in accordance with all applicable national and local electrical codes.
- The range and performance of the wireless control system is highly dependent on the following: (1) distance between devices; (2) layout of the home; (3) walls separating devices; and (4) electrical equipment located near devices.
Turn off the local electrical power by either switching off the circuit breaker or removing the fuse from the fuse box. To ensure the wires do NOT have power running to them, use an inductive voltage detector.
NOTE: The back box wiring shown in this document is an example. Your wire colors and functions may differ. If you are not sure which wires are the Line In/Hot, Neutral, Load, and Earth Ground wires, have a trained electrician perform the installation.
Prepare each wire. Wire insulation should be stripped back 5/8 of an inch from the wire end (see Figure 1).
Figure 1. Strip wire insulation
Identify your wiring application, and then see the appropriate wiring diagram in the “Sample Wiring Configurations” section below.
IMPORTANT! Not grounding this product as described in the section,
“Warnings and Considerations,” may result in an installation less immune to
damage caused by electrical disturbances, such as ESD or lightning, and may
void the warranty.
Identify and connect the dimmer wires to the back box wires using the wire
nuts.
IMPORTANT! The yellow wire is not a traditional traveler. It cannot
directly power a lighting load. It must be used only to connect to a Control4
Auxiliary Keypad. See “Sample Wiring Configurations.”
TIP: If you are using a Control4 push-on (screwless) faceplate in a
multi-gang installation, attach the black faceplate sub-plate to all of the
devices that will be installed into the wallbox prior to attaching the devices
to the wallbox. This will help ensure that all the devices are properly
aligned and on the same plane after installation.
Fit the wires back into the back box. Bend the wires in a zigzag pattern so that they easily fold into the back box (Figure 2).
Figure 2. Bend the wires
Align the dimmer to the back box (the load rating label should be at the
bottom) and fasten it with screws. Tighten the screws until the back side of
the yoke plate is even with the wall surface, but no further. Overtightening
can warp the dimmer and cause mechanical malfunction.
Install the Control4 Faceplate following the instructions in the Faceplate
Installation Guide or attach a standard Decora-style faceplate.
Turn ON power at the circuit breaker or replace the fuse from the fuse box.
Operation and configuration
On initial power-up, all status LEDs on the dimmer will illuminate green
indicating that the device has power. To set up this dimmer for use with a
Control4 system, refer to the Composer Pro User Guide.
To operate this dimmer as a stand-alone device:
- Click the top button to turn the light on.
- Click the bottom button to turn the light off.
- Press and hold the top button to ramp the light up. Release the button at the desired light level.
- Press and hold the bottom button to fade the light down. Release the button at the desired light level.
Button tap sequences
The button tap sequences are defined in the table below. Button tap sequences
that require a single (1) button should use the top button.
Function | Button sequence |
---|---|
Identify | 4 |
ZigBee channel | 7 |
Reboot | 15 |
Factory reset | 9-4-9 |
Leave mesh and reset | 13-4-13 |
Troubleshooting
If the light does not turn on:
- Ensure at least one LED on the face of the dimmer is lit.
- Ensure the light bulb is not burned out and is screwed in tightly.
- Ensure that the circuit breaker is not turned OFF or tripped.
- Check for proper wiring (see “Sample Wiring Configurations”).
- For help on the installation or operation of this product, email or call the Control4 Technical Support Center. Please provide your exact model number. Contact support@control4.com or see the web site www.control4.com.
Care and cleaning
- Do NOT paint the dimmer or its wall plate.
- Do NOT use any chemical cleaners to clean the dimmer.
- Clean the surface of the dimmer with a soft damp cloth as needed.
Legal and warranty information
Find details of the product’s Limited Warranty at
snapav.com/warranty or request a paper copy from
Customer Service at 866.424.4489. Find other legal resources, such as
regulatory notices and patent information, at
snapav.com/legal.
NOTE: If the light flickers, adjust the dimmer’s max/min settings in Composer (e.g. min 15%, max 85%). See ctrl4.co/dimmersettings.
Sample wiring configurations
Figure 3. Single device location, with a neutral connection
Figure 4. Multiple device locations using Auxiliary Keypad, with a neutral connection
IMPORTANT! When used in conjunction with an Auxiliary Keypad (C4-KA-xx), the wire connecting the Auxiliary Keypad to the dimmer must not exceed 150 feet (45 m) at 120VAC, and 100 feet (30 m) at 277VAC.
Figure 5. Multiple device locations using Configurable Keypad, neutral required
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>