ATC W5-u 2kW Wall Mounted 5 Litre Undersink Pacific Water Heater User Manual
- June 6, 2024
- ATC
Table of Contents
- ATC W5-u 2kW Wall Mounted 5 Litre Undersink Pacific Water Heater User
- ATC PACIFIC WATER HEATING INSTALLATION AND OPERATION MANUAL
- IMPORTANT SAFETY INSTRUCTIONS-READ BEFOR USING THIS WATER HEATER
- THESE INSTRUCTIONS SHOULD BE KEPT FOR FUTURE REFERENCE
- GENERAL WIRING DIAGRAM
- HEATER MOUNTING INSTRUCTIONS
- WATER PIPE CONNECTIONS
- For Inlet water pressure up to 4.1 bar.
- For Inlet water pressure up to 4.1 bar where expansion in the mains is
- CLOSED SYSTEM THERMAL EXPANSION
- ELECTRICAL CONNECTION
- OPERATING INSTRUCTIONS
- Start Up and Testing
- To start the heating cycle:
- To Set the Temperature.
- PERIODIC MAINTENANCE AND PARTS REPLACEMENT
- Draining the Heater
- Removing the Heating Element
- De-scaling the Heating Element
- Changing the anode rod
- To replace the Anode:
- Changing the thermostat
- Resetting the high-level thermal cutout
- To reset the High Level Thermal cutout:
- TROUBLESHOOTING
- Indicator Light not on
- Brown water
- Odor in water
- Water is too hot
- No Water flow
- Unit Leaking
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ATC W5-u 2kW Wall Mounted 5 Litre Undersink Pacific Water Heater User
Manual
ATC PACIFIC WATER HEATING INSTALLATION AND OPERATION MANUAL
W5-u 5 Litre Undersink water heater
W10-u 10 Litre Undersink water heater
W15-u 15 Litre Undersink water heater
5 Litre heater 10 and 15 Litre heaters
IMPORTANT SAFETY INSTRUCTIONS-READ BEFOR USING THIS WATER HEATER
- This water heater must be earthed.
- Locate & install this water heater only in accordance with the provided installation instructions.
- Use this water heater only for its intended use as described in this manual.
- This water heater should be installed by a qualified installer.
- Do not operate this water heater if it is not working properly or if it has been damaged or dropped.
- This water heater should be serviced only by qualified service personnel.
- Failure to examine and if necessary, replace the anode rod at least once a year could cause the tank to fail and leak and void the warranty.
- Cable connection should be to a 13A double-pole Switched Spur.
- This water heater is not suitable for hard water areas unless a suitable water softener is fitted. In areas of hard water, failure to fit a water softener will cause premature unit failure and is not covered under warranty.
THESE INSTRUCTIONS SHOULD BE KEPT FOR FUTURE REFERENCE
1| Cold water Inlet| 5| Heating indicator (5ltr)
LED On/Off Switch (10 & 15Ltr)
| 9| Thermal insulation
---|---|---|---|---|---
2| Hot water Outlet| 6| Outer cover| 10| Sacrificial Anode
3| Temperature adjustment| 7| Electrical heating element| 11| Cold water inlet
4| Cover Screw| 8| High Level Thermal cutout|
TECHNICAL SPECIFICATIONS
Product Code| W5-U| W10-U| W15-U
Capacity| Litres| 5| 10| 14
Gallons| 1.1| 2.2| 3.3
Power| Watts| 2000| 2500
Voltage| Volts| 220-240
Frequency| Hertz| 50-60
Maximum Pressure| Bar| 8
Safety valve Max. Pressure| Bar| 6
Minimum Operating Pressure| Bar| 1
Connection Type| 1/2” Male BSP
Distance Between Connections| mm Center to Center| 100
Thermostat Type| Capillary type
Thermostat Range| °C Min – °C Max| 30-80| 35-75
External Switch| No| Yes
Heating Indicator| LED| Yes
Installation location| Undersink, wall mounted or
standing on rubber feet*
ERP Class| B| B
Heating Time (minutes)| ΔT 35°C| 7| 13| 15
ΔT 45°C| 9| 17| 19
Dimensions| Height| 285| 300| 337
Width| 240| 340| 364
Depth| 240| 330| 354
IP Rating| X4
Weight (kg)| Empty| 4.5| 6.5| 8
Full| 9.5| 16.5| 23
- The ATC Pacific water heaters are supplied with Adhesive rubber pads to mount on the bottom of the heater to allow them to stand rather than be wall mounted.
NOTE: The installer should review the contents of this manual with the owner on com- pletion of the installation.
GENERAL WIRING DIAGRAM
HEATER MOUNTING INSTRUCTIONS
The water heater should be installed close to a water drainpipe so that excess
water from the safety relief valve can drain away without harm; this drain
pipe should always be kept free of obstruction.
Fix the mounting bracket supplied with the heater to the wall; see below for
dimensions of the holes required; always use screws that are suitable for the
wall material and the weight of the heater otherwise the heater may pull the
bracket off the wall.
Hang the water heater on the bracket. Tug downwards on the heater to ensure
that both “fingers “of the bracket are seated in the mounting slots.
The heater can also be stood on its base using the rubber feet provided for
this purpose. Attach the four adhesive feet to the base of the heater before
plumbing. Confirm water piping orientation before wall mounting.
Concrete or Brick
Timber or Plaster
Hang the heater on the Bracket
Note: If using the rubber feet, it is not necessary to use the wall bracket
also.
Should the installer wish to use the bracket as an additional fixing method,
confirm location of bracket with feet attached to heater prior to
installation.
WATER PIPE CONNECTIONS
All water connections to the heater must be made in copper pipe. If using
Qualpex or similar plastic piping method then a minimum of one metre of copper
pipe must be installed between the heater and the plastic piping system. All
pipework between the heater and the safety valve should be in copper and
continue at least 1m from the water heater.
Connect the cold-water inlet pipe to the inlet connection (marked with a blue
ring) and the hot water outlet pipe to the outlet connection (marked with a
red ring).
Dielectric Connections are supplied and should be used as necessary.
The water heater is designed for connection direct to the incoming mains water
supply and accommodation must be made for the expanded water that will occur
with each operating cycle. Regulations permit expanded hot water to be
accommodated within the supply pipe work provided that an expansion relief
valve is fitted (Check Local Regulations in your area). See drawing below.
For Inlet water pressure up to 4.1 bar.
2.8m (5 &10 Ltr) or 4.2m (15 Ltr) is required for expansion in pipework between cold water inlet and non return valve.
Where the expanded water cannot be accommodated in the pipe work due to space
restrictions and the static water supply pressure is under 4 bar, an expansion
vessel should be fitted in between the water heater and the safety relief
valve.
Where static water pressures are likely to exceed 4 bar, fit a pressure
reducing valve.
Note: In this case expansion using the mains is not permitted and an
expansion vessel must be used.
For Inlet water pressure up to 4.1 bar where expansion in the mains is
not possible .
For Inlet water pressure over 4.1 bar.
Note: If a pressure reducing valve is used then allowing for expansion in the
pipework is not possible. An expansion vessel must be used.
CLOSED SYSTEM THERMAL EXPANSION
There is a Pressure relief safety valve supplied with the water heater, the
pressure relief outlet will allow a little water to escape when heating due to
expansion of the water in the tank.
It is recommended to pipe this waste to a tun-dish (Kit-C) and then to waste.
The safety valve has been pre-set in the factory to 6 bar, please do not
adjust.
The Pressure Relief safety valve should be tested by twisting the top in an
anti-clockwise direction until water flows out of the waste outlet; It is
recommended that pressure relief valves are tested at least once every six
months, especially to reduce leakage caused by the buildup of minerals and
corrosion.
When water is turned off, reverse flow should be prevented using an
appropriate non return valve. This is to prevent the element from operating
without water in the tank.
Note: The outlet of the Pressure relief valve should be kept free of
obstruction; it should be installed with the outlet pointing down and plumbed
to waste. A tun dish (Kit-C) is available for this purpose
A 2 Ltr. Expansion vessel (Kit-A) and a Pressure Reducing Valve (Kit-B) are
also available as optional accessories.
ELECTRICAL CONNECTION
All ATC Pacific water heaters come pre-wired with 1.5mm2 2 core and earth. The
heater should be connected by a suitably qualified electrician in accordance
with IEE wiring regulations.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the heater using a suitably rated double pole disconnection switch
with a minimum of 3mm contact gap and protected by an appropriately rated
circuit breaker or RCD.
If this heater is installed in a bathroom it must be supplied from a circuit
that is protected by a high sensitivity RCD with a maximum rating of 30mA.
OPERATING INSTRUCTIONS
- The water heater can be used by children of at least 8 years (as well as by persons with reduced physical, sensory or mental capabilities, or lack of experience or required knowledge) provided that they are under supervision, or after they have been instructed relating to the safe use and have understood the potential dangers.
- Children should not play with the water heater.
- Cleaning and maintenance must be performed by the user and not by unsupervised children.
- Children of less than 3 years should be kept away unless continuously supervised.
- Children aged from 3 years and less than 8 years shall only switch on/off the water heater provided that it has been installed in its intended normal operating position and they have been given instruction concerning use of the heater in a safe way and\ understand the hazards involved, children should always be supervised.
- Children aged from 3 years and less than 8 years shall not plug-in, regulate, clean the water heater or perform maintenance.
- Before connecting the water heater make sure that the voltage is the same as indicated on the device rating label.
- Do not use in presence of gas, inflammable or explosive liquids or substances as defined in BS5345.
Start Up and Testing
Before connecting the power, fill the tank and system with water and check all
the plumbing
for leaks. Ensure that all air is out of the water system; open the hot water
taps before
opening the service valve, open the service valve until constant water flows from the hot outlet. Once water is flowing, close the hot water tap. Failure to carry out this step can crack the lining of the heater and result in leaks.
To start the heating cycle:
Make sure tank is full of water, otherwise damage to the water heater may
occur.
For the 10 and 15 Litre heaters turn the switch on and then follow the 5Ltr
instruction below.
For the 5 Litre heater, turn the temperature adjustment knob clockwise to 3/4
maximum and the indicator light will come on to show the element is heating.
The indicator light will remain on until the temperature setting has been
reached, at which point the light will go off. When the temperature drops
below the set point of the thermostat the indicator light will automatically
come back on. This is a “pilot light” indicating the unit is in the heating
process.
To Set the Temperature.
After the water heater has reached the set point outlined above check the water tempera- ture — do not place hands directly under water outlet as there could be a risk of scalding. If it is necessary to adjust thermostat turn the dial clockwise to increase the temperature and anti-clockwise to decrease it.
PERIODIC MAINTENANCE AND PARTS REPLACEMENT
Maintenance should only be carried out by a qualified service person.
Note: For most of these operations the power supply should be turned off and
the water will have to be drained from the heater.
Draining the Heater
- Isolate the power supply.
- Shut off water inlet valve.
- Remove water heater and invert over a sink to allow water to drain from tank safely.
Removing the Heating Element
- Turn off power supply and drain the heater (see previous section).
- Remove the cover screw and cover.
- Disconnect electrical cables attached to element.
- Unscrew the heating element retaining nuts and remove compression bracket.
- Remove the element.
De-scaling the Heating Element
Scale deposits can dramatically affect the heating efficiency of the element. Heavy scale can even cause the element to burn out. The element can be descaled either chemically or manually:
- Remove heating element (see previous section)
- Soak the element in white vinegar or other descaling solution. Once descaled, rinse
De-scaling the Heating Element Scale deposits can dramatically affect the heating efficiency of the element. Heavy scale can even cause the element to burn out. The element can be descaled either chemically or manually:
- Remove heating element (see previous section)
- Soak the element in white vinegar or other descaling solution. Once descaled, rinse the element well with fresh water, OR,
- Once the element has dried up, use a soft brush (nonmetallic to prevent damaging the stainless-steel sheath) on element, and brush the dried mineral off.
- Check and replace anode rod as required, (see below).
- Reinstall the element with gasket and make the electrical connections.
- Reinstall the water heater as per above normal installation procedure.
- Refill tank with water before restoring power.
Changing the anode rod
The anode rod helps protect the tank against corrosion. The magnesium anode
rod needs to be inspected and changed every year.
Galvanic and electrolytic corrosion can be caused by non-municipal water
supplies or low-level stray electrical currents in the water heater.
Galvanic and electrolytic corrosion can destroy a tank and can cause dirty
water. If this happens examine the anode rod immediately.
Rapid degradation of the anode rod (less than 1 year) may indicate the
presence of galvanic corrosion or high acidity/alkalinity in the water supply.
To replace the Anode:
- Turn off the power supply and drain the heater (see previous section).
- Remove heating element (see previous section).
- Remove the spent anode from the element by twisting the spent anode anti-clockwise and replace it with a new anode rod.
- Replace heating element (see previous section).
- Reinstall the water heater and refill tank with water before restoring power.
Changing the thermostat
- Turn off power supply.
- Remove cover screw and cover. Remove dial from outside of cover.
- Disconnect the spade connection wires on the on thermostat.
- Remove and retain rubber plug holding the capillary sensor in the element and remove capillary bulb.
- Unscrew and remove the screws holding the thermostat to the cover.
- Install new thermostat and re-attach wiring and screws.
- Re-install the capillary sensor into the sensor pocket hole in the element and install rubber plug into top of the sensor pocket.
- Re-install cover and cover screw and reinstall adjustment dial.
Resetting the high-level thermal cutout
Occasionally the high-level thermal cutout may trigger and shut the water
heater down.
This occurs when water temperature exceeds 93°C, at this temperature the high-
level thermal cutout will shut off power to the heating element
5 Litre Hi Level Reset 10 and 15 Litre Hi Level Reset
To reset the High Level Thermal cutout:
- IMPORTANT: Disconnect heater from electrical power.
- Remove the cover screw and cover.
- Firmly press reset button (see above) and listen for a “click”.
- Replace the cover and cover screw.
- Reconnect power.
- IMPORTANT: Check the operation of the thermostat, turn temperature dial from high to low, if the red light does not go off on low setting, turn off the power supply, and call a qualified service person to replace thermostat.
- If the system works, please set thermostat to desired setting.
TROUBLESHOOTING
Water does not heat up
-
Make sure the power supply is on and there is power available.
-
If light does not come on, check that the reset button is pushed in; follow steps from previous section.
-
If the indicator light works properly but the temperature does not get hot at the tap, test for a plumbing crossover. Shut off cold supply to heater and open hot water tap.
There should be no water flowing. Any continued flow indicates a crossover which will affect the temperature and will need to be corrected. -
Replace heating element (see previous section on changing the heating element).
Indicator Light not on
- If the light does not come on, but water gets hot, check for faulty bulb.
- Check reset button; follow steps from previous section.
Brown water
- Brown or rusty water indicates a “spent” anode rod. Replace anode rod.
Odor in water
- Smells from the water are usually due to an unusual reaction between local water and the heater’s anode, check anode rod.
This usually occurs on non-municipal water supplies.
Water is too hot
- Turn the temperature selector dial counter anti-clockwise to lower temperature.
- If temperature does not change then replace the thermostat.
No Water flow
- Check service valve is open and ensure minimum operation pressure is above 1 bar.
Note: This water heater is not suitable for use on gravity fed systems.
Unit Leaking
- Check water connection fittings at the top of tank, ensure the connections to the water heater are sound and are not the cause of the leak; if they are leaking, tighten the connections.
- Inspect heating element gasket for cracks or perishing if there are any signs of damage replace element and gasket together.
NOTE: Elements and Gaskets should always be replaced together; do not reuse an old gasket.
WARRANTY
ATC Electrical and Mechanical provides a two year limited parts warranty for
the ATC
Pacific water heaters as long as the unit has been installed, used and
maintained in accordance with the information provided in this manual. For
full terms and conditions of sale and warranty please see www.atc.ie.
In order to arrange parts for the heater, the information listed below is
required. It is recommended to write this information below and keep this
instruction manual in a safe place. Serial Number: Date of Manufacture: Date
of Purchase: Location Purchased:
ERP RATING INFORMATION
Model| | W5-U| W10-U| W15-U
Storage volume (V)| L| 5| 10| 14
Declared load profile| | XXS| XXS| XXS
Water heating energy efficiency class| | B| B| B
Water heating energy efficiency (ηwh)| %| 32.0| 32.0| 32.0
Annual electricity consumption (AEC)| kWh| 576| 576| 576
Sound power level (LWA)| dB| 15| 15| 15
Daily electricity consumption (Qelec)| kWh| 2.781| 2.781| 2.781
Mixed water at 40°C (V40)| I| —| —| —
Thermostat temperature settings of the wa-
ter heater, as placed on the market
| °C| 75| 65| 65
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate
collection systems)
This marking shown on the product or its literature, indicates that it should
not be disposed of with other household wastes at the end of its working life.
To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources
Household users should contact either the retailer where they purchased this
product, or their local government of- fice, for details of where and how they
can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract. This product should not be mixed with
other commercial wastes for disposal.