Installation plan
Vented dryer
PDR 908 EL
It is essential to read the operating and installation instructions before
installation and commissioning.
This prevents both personal injury and damage to the appliance.
United Kingdom
Miele Co. Ltd., Fairacres, Marcham Road
Abingdon, Oxon, OX14 1TW
Professional Sales, Tel: 0845 365 6608
E-mail: professional@miele.co.uk
Internet: www.miele.co.uk/professional
Australia
Miele Australia Pty. Ltd.
ACN 005 635 398, ABN 96 005 635 398
1 Gilbert Park Drive, Knoxfield, VIC 3180
Tel: 1300 731 411
Internet:
www.miele.com.au/professional
E-mail: sales@miele-professional.com.au
China Mainland
Miele Appliances Ltd.
Miele Electrical Appliances Co., Ltd.
1-3 Floor, No. 82 Shi Men Yi Road
Jing’ a District, 200040 Shanghai, PRC
Tel: +86 21 6157 3500, Fax: +86 21 6157 3511
E-mail: info@miele.cn, Internet:
www.miele.cn
Hong Kong, China
Miele (Hong Kong) Ltd.
41/F – 4101, Manhattan Place
23 Wang Tai Road, Kowloon Bay, Hong Kong
Tel: (852) 2610 1025, Fax: (852) 3579 1404
Email: customerservices@miele.com.hk
Website: www.miele.hk
India
Miele India Pvt. Ltd.
1st Floor, Copia Corporate Suites,
Commercial Plot 9, Mathura Road, Jasola,
New Delhi – 110025
E-mail: customercare@miele.in, Website:
www.miele.in
Ireland
Miele Ireland Ltd.
2024 Bianconi Ave., Citywest Business Campus, Dublin 24
Tel: (01) 461 07 10, Fax: (01) 461 07 97
E-Mail: info@miele.ie, Internet:
www.miele.ie
Malaysia
Miele Sdn Bhd
Suite 12-2, Level 12
Menara Sapura Kencana Petroleum
Solaris Dutamas No. 1, Jalan Dutamas 1
50480 Kuala Lumpur, Malaysia
Phone: +603-6209-0288
Fax: +603-6205-3768
New Zealand
Miele New Zealand Limited
IRD 98 463 631
8 College Hill
Freemans Bay, Auckland 1011, NZ
Tel: 0800 464 353
Internet:
www.miele.com.au/professional
E-mail: sales@miele-professional.com.au
Singapore
Miele Pte. Ltd.
29 Media Circle, #11-04 ALICE@Mediapolis
Singapore 138565
Tel: +65 6735 1191, Fax: +65 6735 1161
E-Mail: info@miele.com.sg
Internet: www.miele.sg
South Africa
Miele (Pty) Ltd
63 Peter Place, Bryanston 2194
P.O. Box 69434, Bryanston 2021
Tel: (011) 875 9000, Fax: (011) 875 9035
E-mail: info@miele.co.za
Internet: www.miele.co.za
United Arab Emirates
Miele Appliances Ltd.
Showroom 1, Eiffel 1 Building
Sheikh Zayed Road, Umm Al Sheif
P.O. Box 114782 – Dubai
Tel. +971 4 3044 999, Fax. +971 4 3418 852
800-MIELE (64353)
E-Mail: info@miele.ae, Website:
www.miele.ae
Manufacturer: Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany
Key:
Connection required
AL Exhaust air
ASK Condensate drain hose
B Appliance anchoring
EL Electrical connection
F Appliance feet, adjustable
KG Payment system
KGA Payment system connection
KLA Cooling air ven| Connection optional or required, depending on model
KLZ Cooling air intake
PA Equipotential bonding
SLA Peak-load connection
APCL SST Box plinth
APCL OB Open plinth
APCL 001 Washer-dryer stacking kit
KXM Communication module
ZL Air intake
---|---
Appliance dimensions
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Washer-dryer stack
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Technical data
| | PDR 908 EL
---|---|---
Drying system| | Vented
Drum volume| l| 130
Load capacity| kg| 8.0
Door opening diameter| mm| 370
Electrical connection (EL )
Alternative voltage (convertible by Miele Customer Service Department)| | 1N
AC 230 V
---|---|---
Frequency| Hz| 50/60
Total rated load| kW| 3.24
Fuse rating (B trip rating according to EN 60898)| A| 1 x 16
Supply lead min. cross-section| mm²| 3 x 1.5
Alternative voltage (convertible by Miele Customer Service Department)| | 3 AC
230 V
---|---|---
Frequency| Hz| 50/60
Total rated load| kW| 6.4
Fuse rating (B trip rating according to EN 60898)| A| 3 x 16
Supply lead min. cross-section| mm²| 4 x 1.5
Non-standard voltages MAR 400/440/480 (Marine)| | 3 AC 400/440/480 V
---|---|---
Frequency| Hz| 50/60
Total rated load| kW| 4.5/5.4/6.4
Fuse rating (B trip rating according to EN 60898)| A| 3 x 10
Supply lead min. cross-section| mm²| 4 x 1.5
Supply lead without plug| |
Length of supply lead| mm| 2000
Non-standard voltage MAR 230 (Marine)| | 3 AC 230 V
---|---|---
Frequency| Hz| 50/60
Total rated load| kW| 6.4
Fuse rating (B trip rating according to EN 60898)| A| 3 x 16
Supply lead min. cross-section| mm²| 4 x 1.5
Supply lead without plug| |
Length of supply lead| mm| 2000
Non-standard voltage MAR 208-240 (Marine)| | 2 AC 208-240 V
---|---|---
Frequency| Hz| 60
Total rated load| kW| 3.2/4.3
Fuse rating (B trip rating according to EN 60898)| A| 2 x 30
Supply lead min. cross-section| | 3 x AWG10
Supply lead with plug| |
Length of supply lead| mm| 1830
Variations in the following countries:
Standard voltage 13 A (GB only) | 3N AC 400 V | |
---|---|---|
Frequency | Hz | 50/60 |
Total rated load | kW | 5.47 |
Fuse rating (B trip rating according to EN 60898) | A | 3 x 13 |
Supply lead min. cross-section | mm² | 5 x 1.5 |
Supply lead without plug | ||
Length of supply lead | mm | 2000 |
= standard, Ο = optional, + = only on request, – not available
PDR 908 EL
Standard voltage 13 A (GB only) | 1N AC 220–230 V | |
---|---|---|
Frequency | Hz | 50/60 |
Total rated load | kW | 2.76–2.99 |
Fuse rating (B trip rating according to EN 60898) | A | 1 x 13 |
Supply lead min. cross-section | mm² | 3 x 1.5 |
Supply lead with plug | ||
Length of supply lead | mm | 2000 |
Standard voltage 25 A (GB only) | 1N AC 220–230 V | |
--- | --- | --- |
Frequency | Hz | 50/60 |
Total rated load | kW | 5.03–5.47 |
Fuse rating (B trip rating according to EN 60898) | A | 1 x 25 |
Supply lead min. cross-section | mm² | 3 x 2.5 |
Supply lead without plug | ||
Length of supply lead | mm | 2000 |
Standard voltage (N only) | 3 AC 230 V | |
--- | --- | --- |
Frequency | Hz | 50/60 |
Total rated load | kW | 6.4 |
Fuse rating (B trip rating according to EN 60898) | A | 3 x 16 |
Supply lead min. cross-section | mm² | 4 x 1.5 |
Supply lead without plug | ||
Length of supply lead | mm | 2000 |
Alternative voltage (convertible) | 1N AC 230 V | |
--- | --- | --- |
Total rated load | kW | 3.24 |
Fuse rating (B trip rating according to EN 60898) | A | 1 x 16 |
Supply lead min. cross-section | mm² | 3 x 1.5 |
Alternative voltage (convertible) | 3N AC 400 V | |
--- | --- | --- |
Frequency | Hz | 50/60 |
Total rated load | kW | 6.4 |
Fuse rating (B trip rating according to EN 60898) | A | 3 x 10 |
Supply lead min. cross-section | mm² | 5 x 1.5 |
Standard voltage for CDN & USA | 2 AC 208-240 V | |
--- | --- | --- |
Frequency | Hz | 60 |
Total rated load | kW | 3.2/4.3 |
Fuse rating | A | 2 x 30 |
Supply lead min. cross-section | 3 x AWG10 | |
Supply lead with plug | ||
Length of supply lead | mm | 1830 |
Standard voltage (AUS only) | 1N AC 230 V | |
--- | --- | --- |
Frequency | Hz | 50/60 |
Total rated load | kW | 5.47 |
Fuse rating | A | 1 x 25 |
Supply lead min. cross-section | mm² | 3 x 2.5 |
Supply lead without plug | ||
Length of supply lead | mm | 2000 |
Ven ted (EL ) | ||
--- | --- | --- |
Connection (ext. diameter) | mm | 100 |
Max. exhaust air temperature | °C | 80 |
Electrical connection with 50 Hz/60 Hz | ||
--- | --- | --- |
Max. permissible pressure loss | Pa | 340 |
Max. flow rate w/o counterpressure (0 Pa) in vented mode | m³/h | 285 |
= standard, Ο= optional, + = only on request, – not available
Eq ui po ten ti al bo nd in g (PA)|
---|---
Appliance connection (with installation kit)|
Ο
XC I -Box / XC I -AD interface|
Peak l o ad / en erg y man ag emen t (SL A)|
Appliance connection (with XCI-Box)|
Ο
Payment system co n n section n (K GA)|
Connection of payment systems (with XCI / XCI-AD)|
Ο
Communication mod ul e (XK M)|
Communication module KXM 3200 WL PLT|
Ο
Install to on appliance feet (F )| |
---|---|---
No. of appliance feet| No.| 4
Appliance foot, height-adjustable with thread| mm| ± 5
Appliance foot diameter| mm| 31.7
Ancho ring (B )| |
---|---|---
Anchoring of Miele plinths| |
Miele plinth installation (fasteners included)| | Ο
Required anchor points| No.| 4
Wood screws according to DIN 571| mm| 8 x 65
Rawl plugs (diameter x length)| mm| 12 x 60
Plinth floor anchoring (to be provided on-site)| |
---|---|---
Appliance installation on on-site plinth (concrete or masonry)| | Ο
Min. plinth installation footprint (W/D)| mm| 600/650
Wood screws according to DIN 571| mm| 6 x 50
Rawl plugs (diameter x length)| mm| 8 x 40
Appliance data| |
---|---|---
Overall appliance dimensions (H/W/D)| mm| 850/605/717
Casing dimensions (H/W/D)| mm| 850/596/677
Site-access dimensions (H/W)| |
---|---|---
Min. site-access opening (excl. packaging)| mm| 900/605
Site-access dimensions (H/W)| |
---|---|---
Min. site-access opening (excl. packaging)| mm| 20
Site-access dimensions (H/W)| mm| 300
Min. site-access opening (excl. packaging)| mm| 1000
Weights and floor loads| |
---|---|---
Appliance weight (net weight)| kg| 51.5
Max. floor load in operation| N| 670
Emissions| |
---|---|---
Sound pressure level (in accordance with EN ISO 11204/11203)| dB(A)| 51.5
Heat dissipation rate to the installation site| W| 670
= standard, Ο= optional, + = only on request, – not available
Installation and planning notes
Installation requirements
The tumble dryer should only be connected to a power supply provided in
accordance with all appropriate local and national legislation and
regulations.
In addition, all regulations issued by the appropriate utilities as well as
standards relating to occupational safety and all applicable valid regulations
and technical standards must be observed.
General operating conditions
Ambient temperature in installation room: +2 °C to +35 °C.
Electrical connection
Depending on the model, the appliance is delivered with a supply lead
with/without a plug.
The appliance may only be connected to an electrical system that conforms to
the national and local codes and regulations (BS 7671 in the UK). The
installation must be performed by a qualified electrician.
The data plate indicates the nominal power consumption and the appropriate
fuse rating. Compare the specifications on the data plate with those of the
electrical power supply. It is always recommended to connect the appliance via
a plug and socket so that electrical safety checks, e.g. during repair or
service work, can be carried out easily.
The tumble dryer can either be hard-wired or connected using a plug and socket
connection in accordance with IEC 60309-1. If the appliance is hard-wired, a
dual circuit breaker must be provided on-site. When switched off there must be
an all-pole contact gap of at least 3 mm in the isolator switch (including
circuit breakers, fuses, and contactors according to IEC/EN 60947).
The plug connector or isolator switch should be easily accessible at all
times. If the tumble dryer is disconnected from the electricity supply, the
isolator must be lockable or the point of disconnection must be monitored at
all times.
The tumble dryer should never be connected by an extension cable, e.g. power
strips, to avoid the risk of fire.
New connections, modifications to the system, or servicing of the earthing
conductor, including determining the correct fuse amperage, must be carried
out by a qualified electrician, as they are familiar with the pertinent
regulations and the specific requirements of the electric utility company.
If converting the tumble dryer to an alternative voltage, observe the
instructions in the wiring diagram. The conversion must be performed by the
Miele Customer Service department or by an authorized Miele dealer. The heater
rating must also be adapted.
The tumble dryer must not be connected to devices such as timers which would
switch it off automatically.
References to cable cross-sections in the technical data refer only to the
required mains cable. Please consult relevant local and national regulations
when calculating any other wire gauges.
Vent connection
Hot moist exhaust air should be vented to the atmosphere along the shortest
possible route or connected to a suitable vent system. Depending on the duct
path, the moist exhaust air can condense on the duct walls to a greater or
lesser extent. For this reason, it is recommended to lay ducting with a
downwards slope to the air exit.
If ducting slopes upwards, a condensate trap either with a drip tray or
connection to a suitable on-site floor drain must be fitted in the system at
the lowest point.
Condensate must not flow back into the appliance.
It is permissible to vent exhaust air via an external wall. In this case,
measures must be taken to minimize the risk and annoyance to neighboring
buildings.
The end of exhaust air ducting leading into the open should be protected
against the elements, e.g. using a suitable hood or with a 90° bend.
The cross-sectional area of the ducting must not be reduced or obstructed by
built-in parts. Filters and louvers must not be fitted in the ducting.
Congestion in the line may lead to a drop in appliance performance or to
appliances being switched off to guarantee safety.
Proper functioning of the tumble dryer cannot be guaranteed if the max. permissible pressure loss is exceeded in the on-site vent ducting system.
When connecting several tumble dryers to a common duct, the cross-sectional
area of the duct must be increased accordingly. Additionally, in such a case
every tumble dryer must have its own non-return valve to prevent dryers from
affecting others in the system. This requires the provision of on-site
additional parts.
In the event that exhaust air ducts from several tumble dryers are merged into
a common duct, a non-return device should be installed in each separate line
to prevent backflow.
With complex ducting with many bends and additional components, or with the
connection of several different appliances to a common duct, it is recommended
that a detailed calculation is carried out by a suitable specialist.
Air intake
The air supply for the tumble dryer is taken directly from the installation
site. During operation, adequate ventilation of the installation site should
be guaranteed. Depending on the appliance version, it is necessary to ensure
an intake of fresh air to compensate for the volume of exhaust air extracted
in order to avoid the creation of a vacuum.
It should not be possible to close or otherwise obstruct air intake grilles or
alternative measures should be implemented to ensure that an adequate supply
of fresh air is available at all times during tumble dryer operation.
Equipotential bonding
If necessary, equipotential bonding with good galvanic contact must be
guaranteed in compliance with all applicable local and national installation
specifications.
Connection material for equipotential bonding must be provided on-site or
using a kit available from the Miele Customer service department .
Peak load/energy management
The appliance can be connected to a peak-load or energy management system
using an optional kit.
When the peak-load function is activated, the heating is deactivated. A
message appears in the display to inform you of this.
Payment system
The tumble dryer can be fitted with a single-machine payment system as an
optional accessory using an optional kit (XCI-Box / XCI-AD). The programming
required for connecting a payment system can be carried out during the initial
commissioning process. After initial commissioning, changes may only be
carried out by your Miele dealer
or the Miele Customer Service Department.
Interface
The appliance can be fitted with a KXM 3200 WL PLT communication module.
This module can be used as a WiFi or LAN interface.
The LAN interface provided via the module complies with SELV (Safety Extra Low
Voltage) in accordance with EN 60950. Connected appliances must also comply
with SELV. The LAN connection uses an RJ45 connector in accordance with
EIA/TIA 568-B.
Installation and anchoring
The appliance must be installed on a perfectly smooth, level, and firm surface
which is able to withstand the quoted loads.
The floor load created by the appliance is concentrated and transferred to the
installation footprint via the appliance feet. The tumble dryer should be
leveled in both directions with the aid of the adjustable feet.
Plinth installation
The tumble dryer can be installed on a plinth (open or box plinth, available
as an optional Miele accessory) or on a concrete plinth to be provided on-
site.
The quality of the concrete and its strength must be assessed according to the
appliance load. Ensure that any raised concrete plinth is adequately bonded to
the floor below.
Washer-dryer stack
The tumble dryer can be installed as a washer-dryer stack together with a
Miele washing machine. A stacking kit (optional accessory) is required for
this. Installation of the stacking kit must be performed by the MieleCustomer
Service Department or an authorized Miele service technician.
References
- professional.com.au
- Miele Official UAE | Premium Domestic Appliances Online.
- Miele Professional UK | Discover our Commercial Solutions
- Miele | Home Appliances South Africa
- Miele Professional AU | Discover our Commercial Solutions
- Home
- Miele India | Luxury Home Appliances, Buy Kitchen Appliances Products
- Miele Singapore - Premium and Luxury home appliances
- Miele Professional CA-en | Discover our Commercial Solutions
- Miele Professional US | Discover our Commercial Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>