WeTeLux 90 08 30 30W LED Floodlight Instruction Manual

June 6, 2024
WeTeLux

WeTeLux logo

WeTeLux 90 08 30 30W LED Floodlight

Dear Customers
Instruction manuals provide valuable hints for using your new device.
They enable you to use all functions, and they help you avoid misunderstandings and prevent damage.
Please take the time to read this manual carefully and keep it for future reference.

WeTeLux 90 08 30 30W LED Floodlight-1

OVERVIEW

Safety Notes

Please note the following safety notes to avoid mal-functions, damage or physical injury:

  • This manual belongs to the product. It contains important notes on operating the unit. Please pass it on along with the unit if it is handed over to a third party!
  • Improper use may result in personal injury and property dam-age. Persons unfamiliar with the manual should not operate the LED floodlight.
  • Dispose of the packaging materials carefully; the plastic bags may become a deadly toy for children.
  • Keep the unit out of the reach of children. It is not a toy.
  • Make sure the available mains voltage corresponds to the data stated on the type label.
  • The floodlight is only approved for connection to AC voltage (230 V~ / 50 Hz).
  • Use of the LED floodlight is permitted indoors and outdoors. However, the LED floodlight must not be operated in water and must be mounted on a suitable place. When mounting and op-erating the floodlight make sure moisture, heavy soiling and ex-cessive heating are avoided.
  • The LED floodlight must not be converted or modified!
  • The LED floodlight must not be connected to the power supply while it is in the packaging.
  • The LED cannot be replaced. If the housing has been dam-aged, do not use the LED floodlight and dispose of the device.
  • The LED floodlight was designed for private use and not for continuous professional operation.
  • Do not stare directly into the LEDs and do not direct the light beam towards people or animals.
  • Do not use devices which can strongly focus light for viewing the light beam.
  • Do not continue to use the unit if the unit is damaged. Repair work must be done by a qualified service technician.
  • Disconnect the unit from the power mains if you don’t use it or clean it (unplug, release fuse, etc.).
  • Do not expose the LED floodlight to excessive temperatures, strong magnetic fields or to strong vibrations.
  • Do not use the product in rooms or in poor ambient conditions where flammable gases, vapours or explosive dust may be pre-sent or are present! There is a risk of explosion!
  • Do not immerse any components of the LED floodlight in liquids of any kind.
  • Position the power cord securely so it cannot become a tripping hazard. Do not bend the power cord too much and do not jam the cord or pull it around edges.
  • Immediately replace a broken glass of the floodlight.
  • Allow at least 1 m illuminating distance to other ob-jects.
  • Never cover the product when it is in use.
  • The product is not intended for operation in altitudes of over 2000 meters.
  • Do not disassemble the unit or attempt to modify or repair it yourself. It does not contain parts serviceable by you. In case of questions or problems, turn to our customer service.

Operation

Intended Use
  • The LED floodlight is intended for illuminating house entrances, drive-ways, etc. It may be installed indoors and in outdoor areas. The LED floodlight is dustproof and protected against water jets from any angle (IP65).
  • Any other use than that described above may damage the product. Moreover, this may give rise to hazards such as short-circuiting, fire, electric shock, etc.
  • No part of the product may be modified or converted!
Preparations for Installation
  • The product may only be installed by a qualified technician (e.g. electri-cian) who is familiar with the relevant regulations (e.g. VDE, German electrical wiring regulations)!
  • Improper work, carried out on the mains voltage, endangers not only your own life but also the life of others!
  • If you do not have the expertise required for the installation, do not install it yourself but ask a qualified technician.
  • Observe the safety instructions!
  • Without fail, pay attention to the correct mounting position of the LED floodlight and the connection cable. If installed outdoors, make sure no water can enter the housing when installing the connection cable.
  • The LED floodlight should not be operated near water and other liquids, or in locations where water and other liquids may accumulate. Please keep a minimum distance of 5 m to swimming pools, ponds etc.
  • The floodlight must not be mounted on or near flammable surfaces.
  • The LED floodlight should not be mounted near flammable and moving objects, such as furniture, decorative material, curtains, candles, etc.
  • Mount the LED floodlight only on a stable surface (wall/ceiling). The installation site must be stable and must not be exposed to vibrations. Depending on the substrate, use suitable screws and dowels.
  • The LED floodlight must be protected on the sub-distribution board by a 10/16A fuse. An earth leakage circuit breaker must be installed before this (FI protective switch).
  • The LED floodlight must be disconnected from the power supply during installation. It is not sufficient to just turn off at the light switch!
  • Turn the power off by removing the corresponding circuit fuse or switch off at the circuit breaker. Secure it against an unauthorised re-start, e.g. with a danger sign. In addition, switch off the associated earth-leakage circuit breaker.
  • Check that the mains connection is current free with a suitable tester.
  • The earth protection cable must be connected when installing the LED floodlight.
  • Do not install the LED floodlight, if the LED floodlight is replacing an existing light and there is no protective earth cable available. First, draw a new mains cable.
  • Where the protective earth is not connected, a fault with the mains voltage might result in the metal housing of the LED floodlight becom-ing live. There is a risk of a life-threatening electric shock!
  • When drilling in walls and ceilings, pay attention to cables, gas and water pipes.

Mounting/Installation

  1. Unscrew the lock nut (5) from the cable gland (4) and guide the power cable through the lock nut and the waterproof grommet (6).
  2. Connect the three wires of the power cable with the lustre terminals.

N = Blue
L = Brown/Black
= PE (Green/Yellow)
WARNING! Risk of electric shock! The floodlight may only be operated when connected to ground.
Hint: If the floodlight glows faintly when OFF after connecting, switch the cables in the terminals L and N.

  1. Re-tighten the lock nut (5).
  2. Secure the power cable with the waterproof grommet (6).
  3. Install the wall mount (1) with two or three suitable screws securely to an appropriate place. Make sure the floodlight is securely mounted.
  4. Tilt the floodlight to the desired angle and tighten the hinge adjusting screws (7) of the wall mount to secure its position.

Switching ON
The LED floodlight is switched on by plugging into mains or by supplying power.

Cleaning
Clean the housing of the floodlight only with a dry or lightly moistened cloth. Do not use aggressive chemicals or abrasives for cleaning.

Technical Data

Rated Voltage 230 V~ 50 Hz

Power Cable

| 3 x 1.0 mm 2

3 x 1.5 mm 2

Illuminant| 30 W, 6500 K, 2400 Im
Colour Rendering| > 65 Ra
Power Consumption when OFF| < 0.5 W
Dimmable| No
Degree of Protection| IP65
Protection Class| I
Dimensions| 195 x 150 x 80 mm
Weight| 883 g

EC Declaration of Conformity

We, the Westfalia Werkzeugcompany, Werkzeugstraße 1, D-58093 Hagen,declare by our own responsibility that the product  30 W LED Floodlight, 6500 K, 2400 lm Article No. 90 08 30 is according to the basic requirements, which are defined in the European Directives and their amendments.

2011/65/EU
Restriction of the Use of certain Hazardous Substances in electrical and electronic Equipment (RoHS)

2014/30/EU
Electromagnetic Compatibility (EMC)
EN 55015:2019+A11, EN 61547:2009,
EN 61000-3-2:2014, EN 61000-3-3:2013

2014/35/EU
Low Voltage Directive (LVD)
EN 60598-1:2015+AC+A1, EN 60598-2-5:2015, EN 62471:2008,
EN 62493:2010, EN 62031:2008+A1+A2
2009/125/EC
Energy-related Products (ErP)
Verordnungen/Regulations (EU) 1194/2012

Dear Customer,
Please help avoid waste materials.
If you at some point intend to dispose of this article, then please keep in mind that many of its components consist of valuable materials, which can be recycled.
Please do not discharge it in the rubbish bin, but check with your local council for recycling facilities in your area.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>