Oase 45423 Waterfall Pump Instruction Manual
- June 6, 2024
- Oase
Table of Contents
Waterfall Pump
3700 / 5150
Operating instructions
REMINDER
CALL 1-866-627-3435
BEFORE RETURNING TO THE STORE.
Part | Description | QTY |
---|---|---|
A | Pump | 1 |
B | 1½ in. and 2 in. ID tubing adapter | 1 |
Information about these operating instructions
Welcome to OASE Living Water. You made a great choice with the purchase of
this product Waterfall Pump 3700 / 5150. Prior to operating the unit, please
read the instructions of use carefully and fully familiarize yourself with the
unit. Ensure that all work on and with this unit is only carried out in
accordance with these instructions. Please strictly follow the enclosed
instructions to ensure the safe and correct handling of the product. Keep
these instructions in a safe place. Please also hand over the instructions
when passing the unit on to a new owner.
WARNINGS AND CAUTIONS SYMBOLS
Symbols used in these instructions
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage.
This symbol indicates an imminent danger, which can lead to death or severe
injuries if the appropriate measures are not taken.
Risk of personal injury caused by a general source of danger.
This symbol indicates an imminent danger, which can lead to death or severe
injuries if the appropriate measures are not taken.
Important! The unit is equipped with a permanent magnet. The magnetic field
may affect the function of pacemakers.
Important information for trouble-free operation.
Intended use
Waterfall Pump 3700 / 5150, referred to in the following as “unit”, may only be used as specified in the following:
-
For pumping normal pond water for filters, waterfalls and watercourses.
-
Operation under observance of the technical data.
The following restrictions apply to the unit: -
Do not use in swimming pools.
-
CAUTION – this pump has been evaluated for use with water only.
-
Never run the unit without water.
-
Do not use for commercial or industrial purposes.
-
Do not use in conjunction with chemicals, food products, easily flammable or explosive substances.
-
Do not connect to the domestic water supply.
-
Do not exceed the voltage shown on the pump.
-
Inspect the power cord for damage before installation and maintenance.
-
Do not remove the grounding pin from the power cord plug.
This unit can be dangerous and cause harm if not used in accordance with these
instructions. Any use not in accordance with these instructions or
modification(s) to the unit will void the limited warranty.
Questions, problems, missing parts?
Before returning to your retailer, call us at
1-866-627-3435, 8 a.m.-6 p.m., EST,
Monday-Friday, or email us at customercare@oase-
livingwater.com.
Or visit our website at www.oase-livingwater.com
Installation
WARNING
Risk of electric shock – This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type
receptacle.
Important:
- Always place the unit below water level.
- It is recommended to place the unit horizontally on the ground ensuring its stable position.
- Do not lift the pump by its power cord. Use the handle to lift and maneuver the pump.
-
For maximum water flow, it is recommended that the largest tubing size for your pump is used.
○ If needed, cut the adapter as shown using a hacksaw; consult the packaging for tubing size. -
Attach the adapter to the pump first, then connect tubing to the adapter.
NOTE: Tubing is NOT INCLUDED. -
Attach the other end of the tubing to desired water feature or spillway.
Start-up
Attention! The pump must never run dry.
Possible consequences: The pump will be destroyed.
Protective measures: Check the water level at regular intervals. Always place
the unit below water level.
Attention! The installed temperature sensor automatically turns the pump off,
if it is overloaded. The pump automatically switches on again once the motor
has cooled down. Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 104
ºF – 40 ºC).
Important:
- The unit switches on automatically when a power connection is established.
- Switching on: Connect the power plug to the socket.
- Switching off: Disconnect the power plug.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
- Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
- Isolate the unit before starting any work.
- Secure the unit to prevent unintentional switching on.
WARNING
This pump uses a very strong magnet to achieve superior performance. When
removing the impeller assembly there will be considerable magnetic force
resisting the extraction of the impeller assembly. This is normal. Likewise,
when replacing the impeller assembly there will be a strong magnetic force
pulling the assembly into the pump to potentially cause injury to fingers and
in rare cases damaging the ceramic shaft or rear bearing. Use thick gloves
when replacing the impeller assembly.
Cleaning the unit
-
Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or when a drop in performance is detected. Clean the unit with warm water using a soft brush.
-
Never use aggressive cleaning agents or chemical solutions.
These could attack the housing surface or impair the function. -
In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can be used. Subsequently, clean the pump thoroughly using warm water.
Cleaning the pump
-
Disconnect the pump from the power source
○ Disconnect the tubing. -
Disassemble the screen and remove the impeller housing to expose the impeller assembly.
-
Remove the impeller assembly by pulling on the back a round plate behind the impeller
-
Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing.
Check parts for damages such as cracked rotor, shaft, or bearing, cracks in the magnet, and broken plastics.
Replace parts if necessary. -
Reassemble in the reverse order.
Storage/Winterization
- Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are to be expected.
- Thoroughly clean the unit, check for damage.
- Ensure that the storage place is inaccessible to children.
Wear parts
The impeller unit is a wear part and is excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand
by cutting off the cables. Further information about the recycling of this
product can be obtained from your local municipal authority.
Troubleshooting
Issue | Cause | Solution |
---|---|---|
The unit is not performing its suction function | Power supply not connected |
Connect pump power supply, check the supply lines to make sure the voltage is
correct
Impeller blocked, shaft broken| Remove the inlet screen and/or pump cover, and
impeller housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also check to make sure that the ceramic
shaft or bearings are not broken.
Pump is not completely submerged| Completely submerge pump in the water
Insufficient flow| Pump is not completely submerged| Completely submerge pump
in the water
Screen clogged| Clean
Tubing blocked| Clean or replace tubing
Tubing kinked| Eliminate kink, replace tubing if it is damaged
Excessive flow loss in the tubing due to friction| Reduce tubing length to
reduce frictional loss
Select larger hose diameter, adapt stepped hose adapter to hose diameter.
Pump overload. The flow is automatically stopped to protect the pump.| Clean
the pump housing and impeller assembly
Reduce the ambient temperature (e.g. ensure that the specified water
temperature is adhered to, avoid direct sunlight)
Impeller wom| Replace impeller assembly
The unit switches off after a short running period| Excessive soiled water|
Clean impeller housing, bearing, and impeller assembly
Impeller blocked, shaft broken| Remove the inlet screen and/or pump cover, and
impeller housing to expose the impeller. Turn the impeller to ensure that it
is not broken or jammed by debris. Also, check to make sure that the ceramic
shaft or bearings are not broken.
Water temperature too high| Maximum water temperature: +95° F (+35 °C)
Waterfall Pump| Model| Model
No.| Rated
voltage| Power
consumption| Max. flow rate| Max. head
height| Cord
length| Connection
for hoses| Dimensions
---|---|---|---|---|---|---|---|---|---
3700| 45423| 120V/
60 Hz| 170 W / 1.8 A| 3,700 GPH| 21 ft.| 20 ft.| 1 1/2″, 2″| 9.4 x 5.4 x 6.5
in.
5150| 45424| 230 W/ 2.5 A| 5,150 GPH| 23 ft.
Pos. | Waterfall Pump |
---|---|
3700 | 5150 |
1 | Screen |
2 | Impeller housing |
3 | Impeller assembly |
4 | 0-ring |
5 | 1 1/2 in., 2 in. ID tubing adapter |
Questions, problems, missing parts?
Before returning to your retailer, call us at
1-866-627-3435, 8 a.m.-6 p.m., EST,
Monday-Friday, or email us at customercare@oase-
livingwater.com.
Or visit our website at www.oase-livingwater.com