Black Pearl Network Attached Storage User Guide
- June 6, 2024
- Black Pearl
Table of Contents
- Precautions
- Rack Mount the Chassis
- Install Rack Rails
- Install Data Drives
- Connect Cables & Power On
- Configure the Data Connection
- Create a Volume
- Create a CIFS Share
- Create an NFS Share
- Add the Share to Your Environment
- Additional Documentation
- Contact Spectra Logic
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Network Attached Storage
Quick Start Guide
The Spectra BlackPearl NAS Quick Start Guide helps you get your new BlackPearl NAS system up and running quickly and efficiently.
STOP
Complete all steps in the Quick Start Guide, in order, before attempting to
use your BlackPearl NAS Solution.
If Spectra Logic Professional Services is to install the solution, allow them
to unbox the chassis and follow these instructions. The time needed to install
and configure your BlackPearl NAS solution is approximately 20-30 minutes.
Precautions
A BlackPearl NAS chassis weighs between 61.2 lb. (27.8 kg) and 151.4 lb. (68.6
kg) depending on chassis size and system configuration.
WARNING Observe local health and safety requirements and use a server
lift to raise and stabilize the chassis during installation or removal.
When installing into or removing a chassis from a rack:
- Extend the rack leveling jacks to the floor.
- Ensure that the full weight of the rack rests on the leveling jacks.
- Extend only one rack component at a time. Be careful not to extend the rails beyond safe limits.
- Install stabilizing feet on the rack (recommended).
- Use a rack bolt-down kit (recommended).
- Do not rack-mount the chassis with the front bezel installed.
Unbox & Check Contents
- If you have not already done so, find and read the Installation Overview document.
- Remove the protective cushion, front bezel, and rack mount rail kit.
- With assistance, lift the chassis out of the bottom nest cushion.
IMPORTANT The chassis ships with the chassis rack rails installed. The rails extend past the end of the chassis approximately 3 in. (8 cm). Make sure the rails do not catch
while lifting the chassis out of the box. - Remove the wrapping from the chassis and then place the chassis on a sturdy work surface. NOTE: Save the packaging materials for future use.
- Open the “Open Me First” box and find the Installation Overview document.
- Read the document before proceeding.
- Inventory the contents against the packing list.
Rack Mount the Chassis
Use the instructions in this section to install the required rack hardware before installing the chassis. Rack hardware is included in the accessory box shipped with each chassis. A #2 Phillips screwdriver is required.
Install Rack Rails
1)Locate the position in the rack where you want to install the BlackPearl NAS
chassis.
The chassis should be mounted as low as possible for rack stability.
2) Select either the Left or Right rack rail, and use the Front and Rear
markings on the rail to orient the rail correctly.
3) Position the studs (1) on the front of the rail inside the vertical post of
the rack, and push the studs into the post holes. The latch (2) on the front
of the rail audibly snaps
into place.
4) Lower the back of the rail until the rail is approximately level. Some
racks have Rack Unit markings to help you level the rail.
5) Position the studs on the rear of the rail inside the vertical post of the
rack, and push the studs into the post holes. The latch on the rear of the
rail audibly snaps into place.
6) Using a #2 Phillips screwdriver, secure the rail with one provided M5 screw
and washer each at the front (3) and back of the rail (4).
7) Repeat for the second outer rack rail.
Install Chassis into Rack
Use the instructions in this section to install the BlackPearl NAS chassis into the rack.
-
Extend the middle section (1) of both the rack rails until they lock in place.
-
Using a lift, raise the chassis, and slide the chassis rails into the middle rack rails. NOTE: Do not rack-mount the chassis with the front bezel installed.
-
Pull the blue latches (2) on both sides of the chassis towards the front of the chassis.
-
Slide the chassis the remainder of the way into the rack.
-
To connect the front bezel, connect the USB cable inside the bezel to the USB cable on the front of the chassis. Then attach the bezel to the front of the chassis. The bezel is secured by magnets.
Install Data Drives
If your order included additional data drives, use the instructions in the Data Drive Installation instruction sheet, included in the “Open Me First” box.
Connect Cables & Power On
Use the instructions in this section to connect the management connection, data connection, and power cables.
- Connect an Ethernet cable to the BlackPearl management port (1). NOTE: This port is not used for data transfer.
- Connect an Ethernet cable to the data port (2). For more advanced network configuration, including link aggregation, see Configure the Data Connection in the Spectra BlackPearl NAS User Guide.
- Connect power cables to the power supplies first (3), then connect the
other end to nearby power outlets. The system powers on immediately.
NOTE: For greater power redundancy, connect each power supply to a separate circuit. - Wait five minutes while the system initializes.
Log In
The BlackPearl management port is configured to use the IP address 10.0.0.2.
Spectra Logic recommends using this IP address the first time you access the
BlackPearl user interface and then changing the IP address in the user
interface. If this IP address is already in use, see Configure the BlackPearl
Management Port in the Spectra BlackPearl NAS User Guide.
1)Locate the product serial number on the sticker Positioned on the top-front
of the chassis. The product serial number is the system’s default password.
- Enter the default IP address 10.0.0.2 into a web browser.
- Resolve the security certificate warning.
- Enter the default Username and Password.
Username: Administrator
Password: //product serial number//
NOTE: The username and password are case-sensitive. - Click -> to log in.
- If desired use the instructions in the Spectra BlackPearl NAS User Guide for instructions to change the management port IP address.
User Interface Dashboard
The Dashboard screen displays when you first log into the BlackPearl
management interface.
The Menu bar on the top of all screens helps you navigate the management
interface using drop-down menus.
The left column of the Dashboard shows the status of the system hardware,
storage pools, and volumes.
The right column displays performance information for both network and storage
pools.
The status bar at the bottom of the interface displays system messages and
contains the power button.
Configure the Data Connection
Use the instructions in this section to set up a single-port data connection with an IPv4 address. For instructions on using link aggregation or IPv6 addressing, see Configure the Data Connection in the Spectra BlackPearl NAS User Guide.
-
Select Configuration>Network.
-
Under Network Interfaces, locate the Data # row with a green checkmark next to the name, and select the row (1).
-
In the upper-right corner of the user interface, select Action>Edit.
-
Click the plus sign (+) to create a new row (2).
-
Enter the desired IP Address and enter the network subnet as the Prefix Length (3).
-
If necessary, change the Default Gateway and MTU settings for your network (4).
-
Click Save (5).
Create a Storage Pool
Use the instructions in this section to configure a basic storage pool. For
descriptions of more advanced configuration options, see Create a NAS Storage
Pool in the Spectra BlackPearl NAS User Guide.
IMPORTANT You need the solution summary document provided by Spectra
Logic to complete the instructions below. If the storage pool is not
configured as specified, you may experience performance degradation. After the
NAS solution stores any data, it becomes time-consuming to recreate the
storage pool without deleting data in the storage pool. Contact Spectra Logic
if you do not have your solution summary document.
-
Select Configuration>NAS>Pools.
-
In the upper-right corner of the user interface, select Action>New.
-
Enter a Name (1). Spectra Logic recommends using a short name.
-
Spectra Logic recommends leaving the High Water Mark at 80% and leaving Power Saving Mode is Disabled (2).
-
Select the Number of Drives to use (3). Refer to the solution summary document.
-
Select the Protection Level (4). Refer to the solution summary document.
-
Select the number of Write Performance drives and the number of Metadata Performance drives (5). Unless you have been directed by Spectra Logic to configure performance drives, leave these settings at zero.
-
At the bottom of the New Pool pane, click Create (not shown).
Create a Volume
Use the instructions in this section to configure a basic volume. For descriptions of more advanced configuration options and using NFI, see Create a Volume in the Spectra BlackPearl NAS User Guide.
- Select Configuration>NAS>Volumes.
- In the upper-right corner of the user interface, select Action>New.
- Enter a Name (1). Spectra Logic recommends using a short name.
- Select the Pool you just created (2).
- Spectra Logic recommends leaving the Minimum Size and Maximum Size blank (3).
- For faster performance when sharing the volume with a CIFS share, select Case Insensitive (4). Do not select this option if you plan to share the volume using NFS.
- If desired, select to enable Compression or Access Time for the volume
(5). See the Spectra BlackPearl NAS User Guide for more information. - Click Create (6).
Create a Share
Use these instructions in the next column to create either a CIFS or NFS share. CIFS shares are used in a Windows environment, and NFS shares are used in a Linux environment. For more information on creating a share, see Create a Share in the Spectra BlackPearl NAS User Guide.
Create a CIFS Share
- Select Configuration>NAS>Shares>CIFS.
- In the upper-right corner of the user interface, select Action>New. Select the Volume (1).
- Enter a Name (2). Spectra Logic recommends using a short name.
- The default Path for the volume allows full root access (3). If necessary, edit the network Path for your environment. See Create a CIFS Share in the Spectra
- BlackPearl NAS User Guide for information.
- Optionally, select Read-Only (4).
Click Create (5).
NOTE: In order to access the CIFS share, you must either create a user on
the BlackPearl NAS system with CIFS access or join the system to an Active
Directory domain. or instructions, see Create a CIFS Share in the Spectra
BlackPearl NAS User Guide.
Create an NFS Share
-
Select Configuration>NAS>Shares>NFS.
-
In the upper-right corner of the user interface, select Action>New.
-
Select the Volume (1). The Volume Mount Point has entered automatically.
-
Optionally, enter a Comment (2).
-
Enter the following in Host Access Control (3) to allow a host to have full root access to the share. * norootsquash
NOTE: For instructions on configuring other host access levels, see Create a NFS Share in the Spectra BlackPearl NAS User Guide. -
Click Create (4).
Add the Share to Your Environment
Before you can use the BlackPearl NAS for data operations, you must add the NAS share to your network environment. For CIFS shares, see Create a Share in the Spectra BlackPearl NAS User Guide for additional information. Contact your network administrator if you need assistance.
Additional Documentation
Scan the QR codes below to access additional documentation related to your BlackPearl NAS solution, or go to https://support.spectralogic.com/documentations/documentation.
BlackPearl NAS User Guide | BlackPearl NAS Site Prep |
---|---|
http://support.spectralogic.com/documentation/default-source/user-guides
/blackpearl-nas-solution-user-guide.pdf|
https://support.spectralogic.com/documentation/default-source/user-guides
/blackpearl-nas-solution-site-prep-guide.pdf
BlackPearl NAS Network Setup Tips| BlackPearl HotPair Installation Guide
---|---
|
https://support.spectralogic.com/documentation/default-source/user-guides
/blackpearl-network-setup-tips.pdf|
https://support.spectralogic.com/documentation/default-source/user-guides
/spectra-blackpearl-hotpair-installation-configuration-guide.pdf
Contact Spectra Logic
Phone Support|
---|---
The United States and Canada| 1.800.227.4637 toll-free or 1.303.449.0160
Europe Deutsch Sprechende Kunden| 44 (0) 870.112.2185
Australia| 49 (0) 6028.9796.507
Mexico, Central/South America, Asia,| 1.800.452.137
New Zealand, Africa, Middle East| 1.303.449.0160
Support Website support.spectralogic.com
Trademarks
© 2022 Spectra Logic. BlackPearl, BlueScale, CC, RioBroker, Spectra,
SpectraGuard, Spectra Logic, StorCycle, TeraPack, TFinity, and TranScale are
registered trademarks of spectra Logic Corporation. Eon Protect and SeeVault
are trademarks of Spectra Logic Corporation. MigrationPass is a service mark
of Spectra Logic Corporation. All rights reserved worldwide. All other
trademarks and registered trademarks are the property of their respective
owners.
PN: 90990152 Rev. A