Black Pearl BlackPearl NAS Network Attached Storage User Guide

May 15, 2024
Black Pearl

Black Pearl BlackPearl NAS Network Attached Storage

Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-
product

The Spectra BlackPearl NAS Quick Start Guide helps you get your new BlackPearl NAS system up and running quickly and efficiently.

STOP

  • Complete all steps in the Quick Start Guide, in order, before attempting to use your BlackPearl NAS Solution.
  • If Spectra Logic Professional Services is to install the solution, allow them to unbox the chassis and follow these instructions.
  • The time needed to install and configure your
  • BlackPearl NAS solution is approximately 20-30 minutes.

Precautions

A BlackPearl NAS chassis weighs between 61.2 lb. (27.8 kg) and 151.4 lb. (68.6 kg) depending on chassis size and system configuration.

WARNING
Observe local health and safety requirements and use a server lift to raise and stabilize the chassis during installation or removal. When installing into or removing a chassis from a rack:

  • Extend the rack leveling jacks to the floor.
  • Ensure that the full weight of the rack rests on the leveling jacks.
  • Extend only one rack component at a time. Be careful not to extend the rails beyond safe limits.
  • Install stabilizing feet on the rack (recommended).
  • Use a rack bolt-down kit (recommended).
  • Do not rack-mount the chassis with the front bezel installed.

Unbox & Check Contents

  1. If you have not already done so, find and read the Installation Overview document.

  2. Remove the protective cushion, front bezel, and rack mount rail kit.

  3. With assistance, lift the chassis out of the bottom nest cushion.
    IMPORTANT The chassis ships with the chassis rack rails installed. The rails extend past the end of the chassis approximately 3 in. (8 cm).

  4. Make sure the rails do not catch while lifting the chassis out of the box.

  5. Remove the wrapping from the chassis and then place the chassis on a sturdy work surface. NOTE: Save the packaging materials for future use.

  6. Open the “Open Me First” box and find the Installation Overview document. Read the document before proceeding.

  7. Inventory the contents against the packing list.

Rack Mount the Chassis

Use the instructions in this section to install the required rack hardware before installing the chassis. Rack hardware is included in the accessory box shipped with each chassis. A #2 Phillips screwdriver is required.

Install Rack Rails

  1. Locate the position in the rack where you want to install the BlackPearl NAS chassis. The chassis should be mounted as low as possible for rack stability.
  2. Select either the Left or Right rack rail, and use the Front and Rear markings on the rail to orient the rail correctly.
  3. Position the studs (1) on the front of the rail inside the vertical post of the rack, and push the studs into the post holes. The latch (2) on the front of the rail audibly snaps into place.
  4. Lower the back of the rail until the rail is approximately level. Some racks have Rack Unit markings to help you level the rail.
  5. Position the studs on the rear of the rail inside the vertical post of the rack, and push the studs into the post holes. The latch on the rear of the rail audibly snaps into place.
  6. Using a #2 Phillips screwdriver, secure the rail with one provided M5 screw and washer each at the front (3) and back of the rail (4).
  7. Repeat for the second outer rack rail.Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-2

Install Chassis into Rack

Use the instructions in this section to install the BlackPearl NAS chassis into the rack.

  1. Extend the middle section (1) of both the rack rails until they lock in place.
  2. Using a lift, raise the chassis, and slide the chassis rails into the middle rack rails. NOTE: Do not rack-mount the chassis with the front bezel installed.
  3. Pull the blue latches (2) on both sides of the chassis towards the front of the chassis.
  4. Slide the chassis the remainder of the way into the rack.
  5. To connect the front bezel, connect the USB cable inside the bezel to the USB cable on the front of the chassis. Then attach the bezel to the front of the chassis. The bezel is secured by magnets.

Install Data Drives

If your order included additional data drives, use the instructions in the Data Drive Installation instruction sheet, included in the “Open Me First” box.

Connect Cables & Power On

Use the instructions in this section to connect the management connection, data connection, and power cables.

  1. Connect an Ethernet cable to the BlackPearl management port (1).
    NOTE: This port is not used for data transfer.

  2. Connect an Ethernet cable to the data port HBA (2) (not shown). For more advanced network configuration, including link aggregation, see Configure the Data Connection in the Spectra BlackPearl NAS User Guide.

  3. Connect power cables to the power supplies first (3), then connect the other end to nearby power outlets. The system powers on immediately.
    NOTE: For greater power redundancy, connect each power supply to a separate circuit.

  4. Wait five minutes while the system initializes.Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-5

Log In
The BlackPearl management port is configured to use the IP address 10.0.0.2. Spectra Logic recommends using this IP address the first time you access the BlackPearl user interface, and then changing the IP address in the user interface. If this IP address is already in use, see Configure the BlackPearl Management Port in the Spectra BlackPearl NAS User Guide.

  1. Locate the product serial number on the sticker positioned on the top-front of the chassis. The product serial number is the system’s default password.

  2. Enter the default IP address 10.0.0.2 into a web browser.

  3. Resolve the security certificate warning.

  4. Enter the default Username and Password. The username and password are case-sensitive.

    • Username: Administrator
    • Password: //product serial number//
      NOTE: The serial number is denoted by “SN” on the sticker.
  5. Click -> to log in.

  6. If desired use the instructions in the Spectra BlackPearl NAS User Guide for instructions to change the management port IP address.

User Interface Dashboard

  • The Dashboard screen displays when you first log into the BlackPearl management interface.
  • The Menu bar on the top of all screens helps you navigate the management interface using drop-down menus.
  • The left column of the Dashboard shows the status of the system hardware, storage pools, and volumes.
  • The right column displays performance information for both network and storage pools.
  • The status bar at the bottom of the interface displays system messages, and contains the power button.

Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-
fig-8

Confi gure the Data Connection

Use the instructions in this section to setup a single-port data connection with an IPv4 address. For instructions on using link aggregation or IPv6 addressing, see Configure the Data Connection in the Spectra BlackPearl NAS User Guide.

  1. Select Configuration>Network.
  2. Under Network Interfaces, locate the Data # row with a green check mark next to the name, and select the row (1).
  3. In the upper-right corner of the user interface, select Action>Edit.
  4. Click the plus sign (+) to create a new row (2).
  5. Enter the desired IP Address and enter the network subnet as the Prefix Length (3).
  6. If necessary, change the Default Gateway and MTU settings for your network (4).
  7. Click Save (5).Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-11

Create a Storage Pool

Use the instructions in this section to configure a basic storage pool. For descriptions of more advanced configuration options, see Create a NAS Storage Pool in the Spectra BlackPearl NAS User Guide.

IMPORTANT
You need the solution summary document provided by Spectra Logic to complete the instructions below. If the storage pool is not configured as specified, you may experience performance degradation. After the NAS solution stores any data, it becomes time-consuming to recreate the storage pool without deleting data in the storage pool. Contact Spectra Logic if you do not have your solution summary document.

  1. Select Configuration>NAS>Pools.
  2. In the upper-right corner of the user interface, select Action>New.
  3. Enter a Name (1). Spectra Logic recommends using a short name.
  4. Spectra Logic recommends leaving the High Water Mark at 80% and leave Power Saving Mode as Disabled (2).Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-13
  5. Select the Number of Drives to use (3). Refer to the solution summary document.
  6. Select the Protection Level (4). Refer to the solution summary document.
  7. Select the number of Write Performance drives and the number of Metadata Performance drives (5). Unless you have been directed by Spectra Logic to configure performance drives, leave these settings at zero.
  8. At the bottom of the New Pool pane, click Create (not shown).

Create a Volume

Use the instructions in this section to configure a basic volume. For descriptions of more advanced configuration options and using NFI, see Create a Volume in the Spectra BlackPearl NAS User Guide.

  1. Select Configuration>NAS>Volumes.
  2. In the upper-right corner of the user interface, select Action>New.
  3. Enter a Name (1). Spectra Logic recommends using a short name.
  4. Select the Pool you just created (2).
  5. Spectra Logic recommends leaving the Minimum Size and Maximum Size blank (3).
  6. For faster performance when sharing the volume with a CIFS share, select Case Insensitive (4). Do not select this option if you plan to share the volume using NFS.
  7. If desired, select to enable Compression or Access Time for the volume (5). See the Spectra BlackPearl NAS User Guide for more information.
  8. Click Create (6).Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-14

Create a Share
Use these instructions in the next column to create either a CIFS or NFS share. CIFS shares are used in a Windows environment, and NFS shares are used in a Linux environment. For more information on creating a share, see Create a Share in the Spectra BlackPearl NAS User Guide.

Create a CIFS Share

  1. Select Configuration>NAS>Shares>CIFS.
  2. In the upper-right corner of the user interface, select Action>New.
  3. Select the Volume (1).
  4. Enter a Name (2). Spectra Logic recommends using a short name.
  5. The default Path for the volume allows full root access (3). If necessary, edit the network Path for your environment. See Create a CIFS Share in the Spectra BlackPearl NAS User Guide for information.
  6. Optionally, select Read-Only (4).
  7. Click Create (5).

NOTE: In order to access the CIFS share, you must either create a user on the BlackPearl NAS system with CIFS access, or join the system to an Active Directory domain. For instructions, see Create a CIFS Share in the Spectra BlackPearl NAS User Guide.

Create an NFS Share

  1. Select Configuration>NAS>Shares>NFS.

  2. In the upper-right corner of the user interface, select Action>New.

  3. Select the Volume (1). The Volume Mount Point is entered automatically.

  4. Optionally, enter a Comment (2).

  5. Enter the following in Host Access Control (3) to allow a host to have full root access to the share.

    • norootsquash
      NOTE: For instructions on configuring other host access levels, see Create a NFS Share in the Spectra BlackPearl NAS User Guide.
  6. Click Create (4).Black-Pearl-BlackPearl-NAS-Network-Attached-Storage-fig-15

Add the Share to Your Environment

Before you can use the BlackPearl NAS for data operations, you must add the NAS share to your network environment. For CIFS shares, see Create a Share in the Spectra BlackPearl NAS User Guide for additional information. Contact your network administrator if you need assistance.

Additional Documentation
Scan the QR codes below to access additional documentation related to your BlackPearl NAS solution, or go to https://support.spectralogic.com/documentations/documentation.

Contact Spectra Logic

Phone Support

United States and Canada| 1.800.227.4637 toll free or 1.303.449.0160
Europe| 44 (0) 870.112.2185
Deutsch Sprechende Kunden| 49 (0) 6028.9796.507
Australia| 1.800.452.137
Mexico, Central/South America, Asia, New Zealand, Africa, Middle East| 1.303.449.0160
Online Support
Support Website| support.spectralogic.com

Trademarks
2024 Attack Hardened, BlackPearl, BlueScale, RioBroker, Spectra, SpectraGuard, Spectra Logic, Spectra Vail, StorCycle, TeraPack, TFinity, and TranScale are registered trademarks of Spectra Logic Corporation. All rights reserved worldwide. All other trademarks and registered trademarks are the property of their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Black Pearl User Manuals

Related Manuals