HEATSTRIP THY2200 Intense Electric Heaters Instruction Manual
- June 6, 2024
- Heatstrip
Table of Contents
- THY2200 Intense Electric Heaters
- Product Manual
- Features & Benefits
- MODEL
- Spot heating principle
- Selection guide
- BLACK OFF-WHITE
- Table Layout
- Installation Requirements
- Mounting options
- CEILING
- Standard mounting brackets
- Standard Mounting Bracket
- MOUNTING
- Extension Mount Bracket
- Flush mount enclosure
- Design Features
- Specification
- TT-MTM2 Wall Controller
- Controlling multiple heaters
- Remote Pairing
- Operation
- Thermal Cut-Out Protection
- Warm Up Mode
- Safety
- Maintenance
- TT-MTM2 Controller Installation Guide
- Heater wiring schematic diagrams
- Safety
- Maintenance
- Warranty Terms & Conditions
- Provision of this warranty is subject to:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
THY2200 Intense Electric Heaters
Product Manual
HEATSTRIP ®INTENSE Electric Heaters
Innovative, High Performance Electric Heating Technology Rev B Mar 21
Features & Benefits
High Output radiant heat
HEATSTRIP®Intense electric radiant heaters produce radiant heat that travels
through the air directly to people and surfaces below – similar to the heat
rays emitted by the Sun. Radiant heating is the only viable option for outdoor
or tough indoor sites.
Maximum heat performance – multiple applications
The high temperature output of the HEATSTRIP®Intense is perfect for exposed
outdoor sites, high ceilings and hard-to-heat indoor and outdoor
applications.
Suitable for permanent outdoor mounting, no protection needed.
For outdoor applications, the HEATSTRIP®Intense is suitable for both permanently exposed (eg. courtyards and patios) and undercover installations – does not need to be fully protected from the elements.
Corrosion protection
Built from corrosion resistant alloy, it is suitable for use in most
applications, including difficult corrosive environments such as coastal
areas.
Multi-Purpose Mounting Options
The HEATSTRIP® Intense is supplied with flexible mounting options. The
standard bracket will allow both ceiling and wall mounting, at various
angles, as well as suspension by chains/wires and metal rods.
DIY
The THY2200 & THY2200W is supplied with a lead and plug, and is therefore
ideal for DIY installations with brackets included.
Element
Carbon filament infra-red heating element provides high performance instant
heat.
Warranty
2–year residential and 1-year commercial warranty.
Material & Design
Anodised alloy casing and end caps with a powder coat hexagon grille.
Available in both a black and off-white colour. 2
Specifications – Australia
MODEL
|
POWER (WATTS)
|
CURRENT (AMPS)
|
DIMENSIONS (mm)
|
WEIGHT (Kg)
|
LEAD LENGTH (mm)
|
PLUG
|
COLOUR
---|---|---|---|---|---|---|---
THY2200
|
2200
|
9.2
|
1068 x 120 x 90
|
6
|
1000
|
YES
|
Black
THY3200
|
3200
|
13.3
|
1270 x 120 x 90
|
7
|
1000
|
NO
|
Black
THY2200W
|
2200
|
9.2
|
1068 x 120 x 90
|
6
|
1000
|
YES
|
Off-White
THY3200W
|
3200
|
13.3
|
1270 x 120 x 90
|
7
|
1000
|
NO
|
Off-White
MODEL
HEATER TYPE High intensity electric radiant, infra-red overheat heater with carbon filament element.
OUTPUT 2200 watts or 3200 watts
POWER 230-240 Volts Nominal at 50—60 Hertz, Single Phase
CONNECTION 3 Core Cable 2.5mm2
APPROVALS AUSTRALIA / NZ / EU
MOUNTING HEIGHT MINIMUM RECOMMENDED
MAXIMUM
2.1 m
2.3 m – 2.5 m
2.8m Outdoors and 3m Indoors (For higher ceiling heights, units can be lowered using optional brackets kits)
MOUNTING OPTIONS Suitable for ceiling, wall, and beam mounting as well as suspension by chains & wires using standard brackets. Optional mounting accessories include extension mount poles and flush ceiling mount kit.
PROTECTION RATING IPX5 Protection from water ingress from all directions
MATERIALS OF CONSTRUCTION Anodised alloy casing and end caps with powder
coat grille (THY2200 & THY3200)
Anodised alloy with high temperature Off – White ceramic coating (THY2200W & THY3200W).
Spot heating principle
In most outdoor or difficult-to-heat indoor applications, there are 2 methods when looking at the size and quantity of heaters required.
Option 1 is to comfort heat the entire area based on the total dimensions of the space, regardless of whether the entire area is being fully occupied or not.
Option 2 is to spot heat the high use areas, such as over outdoor tables, BBQ’s, lounges, assembly lines or indoor work stations.
Often it is more practical and efficient to spot heat these areas. Spot heating will help to reduce the initial capital cost, as well as the on-going running costs. Spot heating will allow the area to be “zoned”, meaning heating only the areas that are being used, such as tables in a restaurant or outdoor alfresco area.
The top diagram shows how HEATSTRIP®Intense is recommended to be used directly over a table, while the bottom diagram indicates how to spot heat a large area.
Selection guide
General recommendations for HEATSTRIP®Intense:
- Ideal mounting height: 2.3m to 2.5m, and the maximum is 2.8m. Minimum is 2.1m.
- Ideal mounting location: ceiling mounted, directly above area to be heated (e.g. above a table)
The below table outlines the coverage HEATSTRIP®Intense model (in m2), based on 3 different scenarios. For example, in an outdoor area that is protected from prevailing winds by walls, café blinds etc, (e.g. outdoor enclosed)
This data is based on direct overhead ceiling mounting. If the heaters are wall mounted, the radiant footprint will be reduced.
MODEL
|
INDOOR PROTECTED (m2)
|
OUTDOOR ENCLOSED (m2)
|
OUTDOOR EXPOSED (m2)
---|---|---|---
THY2200
|
14
|
9
|
5
THY3200
|
21
|
13
|
8
THY2200W
|
14
|
9
|
5
THY3200W
|
21
|
13
|
8
BLACK OFF-WHITE
5
Table Layout
General recommendations for HEATSTRIP®Intense:
- Ideal mounting height: 2.3m to 2.5m, and the maximum is 2.8m. Minimum is 2.1m.
- Ideal mounting location: ceiling mounted, directly above area to be heated (e.g. above a table)
For the majority of outdoor applications, the most effective method is to spot heat a table or similar area. The diagrams below provides an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings
Selection are based on HEATSTRIP Intense being mounted at 2.4m from the floor in a fully enclosed undercover outdoor area.
THY2200 THY3200
2x THY2200
THY3200
Installation Requirements
The ideal mounting position for the HEATSTRIP® Intense is on the ceiling, directly above the area to be heated. If this is not possible, HEATSTRIP® Intense can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m to 2.5m.
For mounting heights more than 2.8m outdoors, we recommend the use of the optional accessories to reduce the height of the heater to 2.3m—2.5m. This will increase the effectiveness of your HEATSTRIP®. Refer to the Mounting Accessory section for more information.
Electrical connections/GPO’s should not be located at the back of the heater. They should be located outside the physical footprint of the units to minimize heat build-up behind the units.
The HEATSTRIP®Intense is not suitable for mounting on an incline, along the length.
This Model may be hardwired and connected to an On/Off switch. In this situation, the heater must be installed by a licenced electrician.
Incorrect Installation
|
Correct Installation
---|---
|
|
The heating surface must never
be directed toward the ceiling
|
Installation location — the below diagrams confirm the minimum recommended clearances.
Lights, fans, and sprinklers must NOT be below heater
Mounting options
The installation of HEATSTRIP®Intense is simple and easy with the standard mounting brackets supplied. For other more challenging locations there are a range of mounting options available – refer to below diagrams.
The HEATSTRIP®Intense can be mounted directly to the ceiling, flush mounted into the ceiling, angled downwards on a wall, suspended on chains, poles or attached to beams and rafters. Refer to the following pages for more detailed information on each mounting option.
CEILING
Standard mounting brackets
The HEATSTRIP®Intense comes with a pair of standard mounting brackets. These adjustable brackets allow direct ceiling or wall mount, and come with pre-set angle options of parallel, 22.5° and 45°.
The flexible standard mounting bracket can be turned 90 degrees to mount onto a beam, it can also be used to suspend with chains.
The brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets. The minimum distance (“B”) for each model is listed on the next page. All dimensions shown below are in (mm).
When completing the installation, ensure all screws are tight and unit is secure.
Note: When suspension mounting, chains are not included.
Standard Mounting Bracket
PART No
|
PACKAGED
DIMENSIONS (mm)
|
WEIGHT (kg)
|
MATERIALS
|
COLOUR
---|---|---|---|---
ZBRAK-132B
|
125 x 100 x 40
|
0.2
|
ANODISED
|
BLACK
ZBRAK-132W
|
125 x 100 x 40
|
0.2
|
ANODISED
|
OFF-WHITE
MOUNTING
Fix the two mounting brackets to the ceiling or wall in the desired location (refer minimum bracket centre chart). Make sure the method of fixing (bolts or screws) will be more than strong enough to support the weight of the heater, allowing for strong winds and other conditions.
• Slide the 2 locking brackets into the groove on the back of the heater. Make sure the pins on the locking bracket are facing the matching holes in the top mounting bracket.
• Lift heater into position and secure the 2 locking brackets to the mounting brackets using the screws provided. Make sure the 2 pins on the locking bracket engage with the matching holes in the mounting bracket. The pins will allow for both horizontal or angle mounting as required
• Tighten all screws and tighten the round nut at the top of the bracket, so it locks onto the top part of the mounting bracket.
NOTE: The standard bracket allows for normal or angle mounting of the heater and is suitable for ceiling or wall mounting.
MODEL
|
“B”
MINIMUM DISTANCE (mm)
---|---
THY2200
|
350
THY3200
|
700
THY2200W
|
350
THY3200W
|
700
Left: Suspension mounting, using the standard mounting brackets
Extension Mount Bracket
The Extension Mount bracket allows HEATSTRIP® Intense units to be lowered from high ceilings using rigid connections. The standard length options as part of the kit are 300mm, 600mm, 900mm and 1200mm.
The extension mount bracket utilizes components from the standard bracket kit which is supplied with each heater.
PART No.
(OFF-WHITE)
Suitable for
THY2200W / THY3200W THEAC-043
THEAC-044
THEAC-045
THEAC-046
|
PART No.
(BLACK)
Suitable for THY2200 / THY3200
THYAC – 047
THYAC – 048
THYAC – 049
THYAC – 050
|
PACKAGED
DIMENSIONS (mm)
300 x 150 x 50
600 x 150 x 50
900 x 150 x 50
1200 x 150 x 50
|
WEIGHT (kg)
0.21
0.38
0.55
0.71
|
MATERIALS
Aluminium
Aluminium
Aluminium
Aluminium
|
NOTES
Kit includes 2x300mm extension pole
Kit includes 2x600mm extension pole
Kit includes 2x900mm extension pole
Kit includes 2x1200mm extension pole
---|---|---|---|---|---
Flush mount enclosure
The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP®into a ceiling. They are available for the HEATSTRIP® Intense model, and are supplied as a one-piece unit suitable for mounting individual heaters. Flush mounting can be used with plaster or timber lined ceiling materials.
An ideal mounting height is 2.3m – 2.5m, with a maximum ceiling height of 2.8m in an outdoor enclosed environment. Maxi mum mounting heights should be strictly followed, otherwise the performance of the units may be reduced.
A minimum clearance of 200mm behind the enclosure must be provided.
The enclosure for the THY2200 & THY3200 is manufactured from black powder coated steel, with a black fascia. The enclosure for the THY2200W & THY3200W is manufactured from black powder coated steel, with an off-white fascia.
SUITABLE FOR
MODEL
|
PART No
|
HOLE CUTOUT
DIMENSIONS (mm)
|
OVERALL
DIMENSIONS (mm)
|
WEIGHT
(kg)
---|---|---|---|---
THY2200
|
THYAC – 051
|
1152(L) x 205(W)
|
1208(L) x 258(W) x 201(D)
|
5
THY3200
|
THYAC-052
|
1302(L) x 205(W)
|
1358(L) x 258(W) x 201(D)
|
7
THY2200W
|
THYAC-053
|
1152(L) x 205(W)
|
1208(L) x 258(W) x 201(D)
|
5
THY3200W THYAC-054 1302(L) x 205(W) 1358(L) x 258(W) x 201(D) 7
HEATSTRIP® TT-MTR-PLUG Controller
TT-MTR-PLUG Controller
The TT-MTR-PLUG controller consists of a remote control and a
plug-in wall socket timer unit to provide easy wireless timer
operation of wall plug connected appliances.
The TT-MTR-PLUG has been designed to provide easy remote control timer functionality to wall socket powered HEATSTRIP heaters. The unit can however be used to remotely operate with timer functionality any device powered by a standard 10A Australian wall socket outlet.
Design Features
- The TT-MTR-PLUG provides an easy means of remotely turning on appliances that are normally permanently connected to a standard wall socket.
- An easily selected 1 hour, 2 hour and 4 hour timer function accessible on both the wall unit and re-mote
- Programmable remote control unit capable of controlling multiple units.
Specification
Remote battery
|
CR2025, 3V, Lithium
---|---
Remote range
|
10m+
Wall socket supply
|
220V – 240V, 50Hz
Max Load
|
10A (2400W)
Standby consumption
|
<1W
Remote Frequency
|
38KHz IR
Dimensions (mm)
|
105 (H) x 55 (W) x 60 (D)
Approvals
|
Australian Standards AS/NZ
3105, 3112, 3100
NOTE: Optional Controller (Not Included with heater) Only Suitable for THY2200 & THY2200W.
HEATSTRIP® Wall Controller with Remote
TT-MTM2 Wall Controller
This controller is a custom designed and manufactured controller for HEATSTRIP heaters. It has been designed for ease of use and to provide low running costs of your heater. It provides both temperature control (allowing the user to turn the heat output up or down depending on the ambient temperature and conditions) and a timer for automatic heater shut-off operation.
The timer function has 4 settings: 1 hour, 2 hours, 4 hours or constantly on. This feature is ideal for applications such as BBQ areas, alfresco areas, restaurant dining, assembly line production etc. When continuous heat is not required . The timer also reduces the likelihood of heaters being inadvertently left turned on.
Depending on the ambient temperature there may be a requirement to control the heat output of the heater. The controller has 3 settings, they are High, Medium and Low.
The controller allows a combination of the multiple timer (1/2/4 hour) and heat outputs (High/Medium/Low)
Controlling multiple heaters
It is possible to use one wall controller to control multiple heaters. The wall controller is rated at 16 Amps and 240 volts.
Remote Pairing
All units operate using the same remote control frequency, therefore, multiple wall controllers can be operated using a single remote control.
The remote will function at distances of over 8m when used in a straight line,
This distance reduces when used at an angle.
MODEL
|
MAXIMUM
VOLTAGE (Volts)
|
MAXIMUM
CURRENT (Amps)
|
PACKAGED
DIMENSIONS (mm)
|
UNIT
WEIGHT (kg)
---|---|---|---|---
TT-MTM
|
240
|
16
|
150 x 95 x 55
|
0.3
Operation
Press “On/Off” button to turn power on and off.
Once turned on, the controller will default to High power setting and will be permanently on (no timer function). Press “POWER” button to select the desired power setting by cycling through HIGH—MEDIUM-LOW. When power setting is at high the controller will provide continuous power. When power setting is at “MEDIUM” or “LOW” the output alternates between being on and off so that it delivers a lower output to the heater. Press “TIMER” button to set the timer to 1,2,4 hours or permanently on. When permanently on, one of the TIMER LED’s will be illuminat ed. Once the timer is selected, the timer will be started immediately. When the timer has end ed, power will turn off and all LED’s will also turn off.
Thermal Cut-Out Protection
This controller is protected by a thermal cut-out switch. This switch is activated when the temperature of the controller is too high. The controller will cut all power until it has sufficiently cooled. Once it cools the unit will continue working as usual.
Warm Up Mode
The controller is programmed to operate continuously (High setting) for the first 15 minutes of operation regarding less of the selected power setting, this is to allow time for the heater to warm up. After this time it will operate as selected.
Safety
The TT-MTM controller is to be mounted indoors it needs to be away from wet conditions. Ensure the connections are properly connected. The controller needs to be installed according to your local wiring guidelines and regulations . Do not allow any cables, furnishings, flammable materials or other items to obstruct the vents of the controller. Never block the air vents of the controller.
Never block the air vents of the controller. Do not put anything in the vents of the controller. The appliance is not intended for use by persons (Including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge , unless they have been given supervision or instruction concerning use of the appliance by person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
Maintenance
The TT-MTM Controller is made from durable materials, however regular care and maintenance of your controller will help prolong the life of the product. It is recommended that you dust the controller to keep the surface clean. Cleaning at least every three months will reduce the amount of dust build up and keep it looking at its best. Do not use any abrasive materials or product s to clean the controller, this includes solvents, citrus based cleaners or other harsh cleaning products. Do not use water or a damp cloth to clean the controller. The remote uses a CR2025 3V lithium battery. If the red light on the remote stops working then change the battery.
TT-MTM2 Controller Installation Guide
The TT-MTM2 Controller required sufficient air circulation in order to provide continuous operation on the high power load setting. The vents must always remain clear; never block or cover the vents. An ideal controller installation will provide significant space around the back of the controller. In
stalling into restricted spaces, such as brick walls, may result in overheating if adequate ventilation is not provided.
Heater wiring schematic diagrams
It is recommended to install an ON/OFF isolation switch before the controller and ensure the unit is turned OFF after use.
Multiple heaters can be operated using a single controller, however the maximum current rating of 16A must not be exceeded. For direct wiring to the controller, the maximum is generally on heater unit unless the combined maximum current is less than 16A. For example, 2x THH1800A can be connected directly to the controller.
Below are example circuits indicating potential installation configurations.
Always check with your electrician and ensure all wiring is in accordance with local regulations. 1x THY2200 or THY2200W
Safety
HEATSTRIP®Intense has an IP rating of X5. This means it is safe for water ingress from all directions. The HEATSTRIP® can be safely hosed down.
HEATSTRIP® has undergone extensive testing both in laboratory conditions; in Thermofilm’s assembly facility in Melbourne and field trials in Australia and overseas. It has been this testing that gives the purchaser the confidence of a high quality product.
Independent laboratory testing has confirmed Thermofilm’s full compliance with Australian and other International Standards. This includes CE, AS/ANZ, UL/CSE
HEATSTRIP®is Class 1 equipment and must be earthed.
In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do not touch any part until 30 minutes after it is turned off.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the heater.
If installed in wet areas, the heater switches or controls must be located so that they cannot be touched by persons in the bath or shower.
The heater needs to be installed as per the installation instructions paying special attention to the minimum clearances. The heater needs to be mounted on a rigid bracket or fixing.
The heater must not be mounted immediately below or in front of a socket outlet.
In case of a heater fault or damaged supply lead, the appliance should be returned to the point of purchase for return to Thermofilm for repair.
Maintenance
The HEATSTRIP®is made from durable materials, however regular care and maintenance of your heater will help prolong the life of the heater.
It is recommended that you clean the heater with a soft cloth, gently wipe the surfaces of the heater with a mild detergent to remove the built up contaminants from the environment. Then rinse all detergent off the heater. All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of the heater. In this case, additional cleaning and maintenance may be required. The cleaning process at least every three months will reduce the amount of build up and keep it looking as best it can. If the heater is in a corrosive environment eg. salt spray, we recommend that you clean your heater with a light spray of fresh water every week. After cleaning, turn the heater on for 20 minutes to dry any water residue and prevent water staining.
Before cleaning or inspection activity, the heater must be switched off and cooled down completely. Do not use any abrasive materials or products to clean the heater, this includes solvents, citrus based cleaners or other harsh cleaning products.
When handling the heater, ensure that your hands are clean or that you use clean gloves as grease or dirt can mark the surface of the heater.
Do not use high pressure water to clean heaters, light water spray only.
Warranty Terms & Conditions
The below Warranty Terms and Conditions apply for New Zealand and Australia only. For international warranty please refer to international warranty terms and conditions.
Thermofilm warrants to the original owner that HEATSTRIP®Intense products will be free from defects in materials and workmanship for a period of 24 months for residential applications (and 12 months for commercial applications) from the date of purchase in accordance with the following warranty terms and conditions.
Provision of this warranty is subject to:
- The HEATSTRIP®product must be installed in accordance with the Installation Instructions and relevant electrical standards and codes.
- The HEATSTRIP®product must be maintained and cleaned according to instructions detailed in the Installation Manual.
- There is no warranty expressed or implied with regard to capacity requirements. The selection of the unit or units depends entirely upon the system design and capacities as determined by the purchaser.
- The customer has not repaired, opened or altered the product in any unauthorized manner.
- This warranty excludes damage to the product or components arising from circumstances outside the control of Thermofilm, including, but not limited to, where the product is not used for intended purpose; where the product has been rectified in any way; incorrect installation; incorrect power supply; damaged caused during delivery; misapplication, misuse, abuse, vandalism, lack of maintenance or accident.
- Thermofilm’s obligations under this warranty are limited to repair or replacement at Thermofilm’s factory of any components of the product which Thermofilm identifies to its satisfaction to be defective.
- Transportation charges involved in return of the product to the Thermofilm factory (or any other location authorised in writing by Thermofilm) is the sole responsibility of the customer.
- All products are inspected and tested before dispatch and are at the risk of the purchaser after the shipment from the Thermofilm factory, if not delivered by Thermofilm to destination.
- Discolorations of the surface may occur after a period of time, this does not constitute a warrantable event.
- Twisting and bending of the heaters may occur, this does not constitute a warrantable event.
- No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm.
- Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts, repairing, removing, installing, servicing, transportation or handling of parts to complete products, and assumes no liability on parts repaired or replaced without written authorisation. Thermofilm shall not be liable for any default or delay in performance of its warranty obligations caused by any circumstances beyond its control, including, but not limited to, judicial or government restrictions, strikes, fires, floods, abnormal weather conditions, delayed supply of components.
Should products be determined as damaged on arrival, immediately notify the transport company of the condition and have them noted on the freight documents. If damage is discovered after unpacking, demand immediate inspection by the transportation company and insist that a record of the damage is made on the freight documentation.
The customer warrants using the product in accordance with:
- Any instructions provided to it by Thermofilm from time to time.
- All government and local regulations, including but not limited to all relevant electrical, environmental laws and regulations governing the installation, storage, use, handling and maintenance of the goods.
- All necessary and appropriate precautions and safety measures relating to the installation, storage, use, handling and maintenance of goods.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
All warranty requests for repairs or replacements must be accompanied by a complete “Warranty Claim Form” available from Thermofilm, together with proof of purchase (and where possible, photos of the installation) and the heater returned to the place of purchase.
In the event of a warranty claim, the goods need to be returned to the distributor/retailer for repair/replacement. Contact
Thermofilm Australia Pty Ltd
17 Johnston Court, Dandenong South, Victoria 3175, Australia
Telephone: (03) 9562 3455,
Email: info@thermofilm.com.au
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>