HEATSTRIP TF2200RW Max Range Commercial Grade Radiant Electric Heater Instruction Manual
- June 5, 2024
- Heatstrip
Table of Contents
HEATSTRIP TF2200RW Max Range Commercial Grade Radiant Electric Heater
HEAT STRIP
Electric heater for protected undercover outdoor and indoor areas such as
alfresco areas, verandas, patios, garages, bathrooms etc.
Features & Benefits
- • 2200 Watts
• Gentle heat output, slimline design.
• LED control panel with easy On/Off functionality, 3 heat levels and adjustable 0-24 hour timer.
• Suitable to heat a 3-4m2 area, when ceiling mounted.
• Anodised alloy construction. Profiled off-white heater. No glow.
• Supplied with 1.5m lead and plug and mounting brackets for DIY installation.
• Direct overhead ceiling mounting is the preferred mounting method.
Specifications
Model | TF2200RW |
---|---|
Heater Type | Electric radiant overhead heater |
Power | 230-240 Volts Nominal at 50-60Hertz, Single Phase, 2200Watts, 9.2 Amps |
Connection | 1.5M long 3 Core Cable 2.5mm2 with Plug |
Approvals | Australia/NZ |
Heating Area (m2) | 3-4 |
Mounting Height | MINIMUM 2.1m |
RECOMMENDED 2.3m-2.4m
MAXIMUM 2.5m
Mounting Options| Suitable for ceiling and angled wall mounted using the
provided brackets (Brackets Materials of construction: Black powder coated
mild steel)
Protection Rating| IPX4
Dimensions & Weight| 1144mm X 162mm X 50mm 4.7Kgs
HEATSTRIP® TF2200RW
The TF2200RWis a custom-designed and manufactured heater. It has been designed
for ease of use and to provide low running cost. It provides 3 levels of
temperature control, Adjustable set timer option from 0-24 hours with the
touch of a button.
When the heater is plugged in or hardwired , press “power” on the remote, the
power indicator light on the unit will light up and indicate the L1, L2, L3
using the + or – to change the heat settings, To set the timer click through
the 0-24 hour timer .
TF2200RW Functions
L1 is the lowest heat setting and L3 is the highest heat setting.
The timer function has 0-24 hour timer. This feature is ideal for applications
such as alfresco areas, restaurant dining,
assembly line production etc. when continuous heat is not required. The timer
also reduces the likelihood of heaters being inadvertently left turned on.
Remote pairing
All units operate using the same remote control frequency, therefore multiple
heaters can be operated using a single remote control. The remote will
function at distance of over 2m when used in a straight line. This distance
reduces when used at an angle.
Remote battery | 1 x CR2025 (Lithium Battery) Battery Supplied |
---|---|
Remote range | 2m |
Wall socket supply | 220V — 240V, 50Hz |
Max load | 10A (2400W) |
Standby consumption | <1W |
Remote frequency | 38kHz IR |
Remote Control Operation
Signal Transmitter
Receiver is located on the heater.
- To use the remote controller, aim the transmitter to the heater. A line of sight transmission is required for the unit to function.
- The controller does not have a protection rating. The controller must be kept away from wet applications.
- The remote will function at distances of over 2m when used in a straight line. This distance reduces when used at an angle.
Temperature Control Button
The temperature will be adjusted from L1-L2-L3 Heater settings
- L1: Low
- L2: Medium
- L3: High
Timer
Timer function 0-24 hours, press through hours to set the timer
On/Off Button
Press this button once to turn on/off for operation
Battery
1 x CR2025 Battery is required for operation.
Installation Requirements
- The ideal mounting position for the heater is on the ceiling directly above the area to be heated. If this is not possible, the heater can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m to 2.4m and the table is within 1.0m of the wall. Mounting heights above 2.5m are not recommended. Mounting heights between 2.3m – 2.4m are optimal.
- Electrical connections/GPO’s should not be located at the back of the heater. They should be located outside the physical footprint of the units to minimize heat build-up behind the units.
- If the heater is to be mounted on an incline (e.g. vaulted ceiling), ensure the electrical connection is located at the lowest point of the heater.
- Heater can be plugged directly into a standard 10Amp GPO. Heater can also be hardwired by a licensed electrician.
Installation location
the diagrams below provide the minimum recommended clearances in (mm).
WARNING: This heater is not equipped with a device to control the room
temperature. Do not use this heater in small rooms when they are occupied by
persons not capable of leaving the room on their own, unless constant
supervision is provided.
Standard Mounting Brackets
The HEATSTRIP® TF2200RB comes with a pair of standard mounting brackets. These
adjustable brackets allow direct ceiling or wall mount, and come with preset
angle options of parallel, 22.5˚˚ and 45˚ .
Table Layout
The approximate number of heaters required to heat a common residential table
setting is given below.
Safety
The TF2200RW has an IP rating of X4. This means it is protected against water
splashed from all directions but limited water ingress is permitted. The
TF2200RW has undergone extensive testing both in laboratory conditions, in
Thermofilm’s manufacturing facility and field trials in Australia and
overseas. It is this testing that gives the purchaser the confidence of a
high-quality product. Independent laboratory testing has confirmed
Thermofilm’s full compliance with Australian and New Zealand standards.
TF2200RW is Class 1 equipment and must be earthed.
In operation, this heater is VERY HOT— do not touch any part of the heater
while it is turned on. Do not touch any part until 30 minutes after it is
turned off.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or intellectual capabilities, or lack of experience
and knowledge unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
Do not allow any cables, furnishings, flammable materials or other items come
in contact with any surface of the heater.
If installed in wet areas, the heater switches or controls must be located so
that they cannot be touched by persons in the bath or shower.
The heater needs to be installed as per the installation instructions paying
special attention to the minimum clearances. The heater needs to be mounted on
a rigid bracket or fixing.
The heater must not be mounted immediately below or in front of a socket
outlet.
Warranty Terms & Conditions
The below Warranty Terms and Conditions apply for New Zealand and Australia
only. For international warranty please refer to international warranty terms
and conditions.
Thermofilm warrants to the original owner that HEAT STRIP Elegance products
will be free from defects in materials and workmanship for a period of 12
months from the date of purchase for residential applications and 12 months
for commercial applications in accordance with the following warranty terms
and conditions.
Provision of this warranty is subject to:
- The HEATSTRIP® products must be installed in accordance with the Installation Instructions and relevant electrical standards and codes.
- The HEATSTRIP® products must be maintained and cleaned according to instructions detailed in the Installation Manual.
- There is no warranty expressed or implied with regard to capacity requirements. The selection of the unit or units depends entirely upon the system design and capacities as determined by the purchaser.
- The customer has not repaired, opened or altered the product in any unauthorized manner.
- This warranty excludes damage to the product or components arising from circumstances outside the control of the Thermofilm, including, but not limited to, where the product is not used for intended purpose; where the product has been rectified in any way; incorrect installation; incorrect power supply; damage caused during delivery; misapplication, misuse, abuse, vandalism, lack of maintenance or accident.
- Thermofilm’s obligations under this warranty are limited to repair or replacement at Thermofilm’s factory of any components of the product which Thermofilm identifies to its satisfaction to be defective.
- Transportation charges involved in return of the product to the Thermofilm factory (or any other location authorized in writing by Thermofilm) is the sole responsibility of the customer.
- All products are inspected and tested before despatch and are at the risk of the purchaser after the shipment from the Thermofilm factory, if not delivered by Thermofilm to the destination.
- No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm.
- Thermofilm does not participate in any site-related costs or labour expenses incidental to replacement of parts, repairing, removing, installing, servicing, transportation or handling of parts to complete products, and assumes no liability on parts repaired or replaced without written authorization. Thermofilm shall not be liable for any default or delay in performance of its warranty obligations caused by any circumstances beyond its control, including, but not limited to, judicial or government restrictions, strikes, fires, floods, abnormal weather conditions, delayed supply of components.
Should products be determined as damaged on arrival, immediately notify the
transport company of the condition and have them noted on the freight
documents? If damage is discovered after unpacking, demand immediate
inspection by the transportation company and insist that a record of the
damage is made on the freight documentation.
The customer warrants using the product in accordance with:
- Any instructions provided to it by Thermofilm from time to time.
- All government and local regulations, including but not limited to all relevant electrical, environmental laws and regulations governing the installation, storage, use, handling and maintenance of the goods.
- All necessary and appropriate precautions and safety measures relating to the installation, storage, use, handling and maintenance of goods.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You
are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
All warranty requests for repairs or replacements must be accompanied by a
complete “Warranty Claim Form” available from Thermofilm, together with proof
of purchase (and where possible, photos of the installation) and the heater
returned to the place of purchase. In the event of a warranty claim, the goods
need to be returned to the distributor/retailer for repair/replacement.
Thermofilm Australia PTY LTD
17 Johnston Court Dandenong South 3175 Vic | Ph: 03 9562 3455 | E:
sales@thermofilm.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>