GENEINNO T1 Pro External Battery with LED User Manual
- June 6, 2024
- GENEINNO
Table of Contents
GENEINNO T1 Pro External Battery with LED
Introduction
GT_exBAT-1 External battery with LED is a integrated extended battery and LED fill light dedicated equipped for intelligent underwater robots. Connect with the unique extension port of Geneinno Intelligent Underwater Robot through a customized waterproof connector. Can provide 4 hours of extra battery life for underwater robots. It supports multi-level brightness sliding adjustment to provide a longer-lasting underwater exploration experience. Built-in 4 high- brightness LED lights provide additional 6000 lumens of lighting, making the underwater world brighter.
Specification
Dimensions | 472mm*φ36mm |
---|---|
Weight | 1650g(air), 400g(water) |
Maximum Depth | 175m(fresh water) |
LED | 6000lm |
In-put Voltage | DC 12V |
Max Electric Current | 3.8A |
Cycle Charge Times | > 300 |
Working Temperature | -10℃ ~ 50℃ |
Battery | 4400mAh/97.68Wh/22.2V |
Extended Duration | Around 4h |
Charging Time | Around 6h |
Port Type | Dedicated 8-pin waterproof connector |
Product Adaptation | Intelligent underwater robot T1/T1 Pro dedicated |
Usage Guidelines
Support bracket installation
- Use a cross screwdriver to unscrew the four fixing screws of the bracket and remove the original bracket of the underwater robot.
- Replace the original bracket for the support bracket, and install 4 fixing screws with a cross screwdriver.
Note: Need to change to support bracket for accessory application.
Accessory Installation
- Unscrew the sealing metal cover of the waterproof connector of the intelligent underwater robot counterclockwise. Match the slot of battery to the slide rail in the bottom of the host. Slide the battery according to direction indicated by the arrow.
- Push the tail lock to the right to lock the position of the support, the bearing does not move back and forth.
- Push the lock in place, install the screws to locate.
- Insert the connector of the battery into the waterproof connector. Tighten it clockwise.
Note: The connector has an anti-reversal insertion design, please pay attention when inserting, please do not rotate when inserting, to avoid damage to the pin and its internal structure.
Accessory Buoyancy Block Installation
- Align the mounting hole with the hole on bracket, with the arrow of buoyancy block upward.
- Install the wing screw through the hole, insert from the outside to the inside, and tighten the nut by hand.
Note: Four buoyancy blocks needed for the external battery. Please install symmetrically. Excessive installation may affect the underwater operation of the underwater robot.
Device start
- First, connect the external battery to the underwater robot, and then connect the Wireless Relay connector to the robot.
- After the connection is done, the underwater robot is powered on. Use a tablet or smart phone to connect, and enter the control page in the Geneinno APP, click the external battery icon, to control the device.
Note: Please refer to “Geneinno Underwater Robot T1/T1 Pro User Manual“ for APP operation instructions.
Charging Guideline
- Connect the special charger connector to the external battery connector.
- For charging the external battery with LED, please use the standard dedicated charger to charge.
- The charger indicator is red when charging, and turns green when battery is fully charged.
Note: The special charger for external batteries can only charge external batteries, and is not allowed to charge any other devices
Maintenance & Precautions
Precautions
- This product should not be directly exposed to sunlight, high temperature, and ultra-low temperature; the above conditions will shorten the life of the body and battery, and affect product performance.
- When charging, please pay attention to whether the charging port is dry and clean. Please make sure that there is no foreign matter attached to the charging port before charging.
- If the product appears to be in an obvious abnormal state (such as obvious damage to the body, functional failure or missing parts, etc.), please do not continue to use the product, and promptly contact our after-sales or authorized dealers.
- Do not place heavy objects on top of this product, and do not use sharp objects to puncture/beat/impact/squeeze, etc.
- Do not deliberately disassemble, damage or short-circuit this product; do not put it in a fire, ultra-high temperature/ultra-low temperature environment, and do not put it into flammable and explosive objects or strong corrosive solvents and other dangerous substances.
Maintenance instructions
- Please use smooth tools such as cotton cloth to clean the surface of this product.
- After each use of this product, please charge the battery within 24 hours.
- If you do not use it for a long time, please charge and discharge at least once every 6 months.
- If you do not use it for a long time, please adjust the battery to 40%-60%. Store the product in a dry and cool environment, avoid exposure to the sun, humidity or high temperature, keep out of the reach of children.
After-sale service
More information please check in Geneinno APP Help selection. If you need
other after sales support or technical issue, please contact
support@geneinno.com or check our website “Service &
Support”, https://www.geneinno.com/support This manual is subject to update
without prior notice