Lifyfun B05 Bluetooth Fingerprint Password Lock Instruction Manual
- June 6, 2024
- Lifyfun
Table of Contents
App Manaul-181022
TTLOCK App Manual
Scan to Download the App
Please read the manual carefully before installation and keep this manual at a secure place.
- Please refer to sales agents and professionals for information not included in this manual.
Introduction
The App is a smart lock management software developed by Shenzhen Smarter Intelligent Control Technology Co., Ltd. It includes door locks, parking locks, safe locks, bicycle locks, and more. The App communicates with the lock via Bluetooth BLE and can unlock, lock, firmware upgrade, read operation records, etc. The Bluetooth key can also open the door lock through the watch. The app supports Chinese, Traditional Chinese, English, Spanish, Portuguese, Russian, French, and Malay.
Registration and login
Users can register their account by mobile phone and Email which currently support 200 countries and regions on the world. The verification code will be sent to the user’s mobile phone or email, and the registration will be successful after the verification.
Security question settings
You will be taken to the security question settings page when registration is successful. When log in on a new device, the user can authenticate himself by answering the above questions.
login action
Log in with your mobile phone number or email account on the login page. The mobile phone number is automatically recognized by the system and does not input the country code. If you have forgotten your password, you can go to the password page to reset your password. When resetting the password, you can receive a verification code from your mobile phone and email address.
When the account is logged in on the new mobile phone, it needs to be verified. When it is passed, you can log in on the new mobile phone. All the data can be viewed and used on the new mobile phone.
Ways of Identifying
There are two ways of security verification. One is the way to get the verification code via the account number, and the other is the way to answer the question. If the current account is set to the “answer the question” verification, then when the new device is logged in, there will be an “answer question verification” option.
Login successful
The first time you use the lock app, if there is no lock or key data in the account, the home page will display the button to add the lock. If there is already a lock or key in the account, the lock information will be displayed.
Lock management
The lock must be added on the app before it can be used. The addition of a
lock refers to the initialization of the lock by communicating with the lock
via Bluetooth. Please stand beside the lock. Once the lock is added
successfully, you can manage the lock with the app including sending a key,
sending a password, and so on.
When the lock is added, the adder becomes the administrator of the lock. At
the same time, the lock cannot enter the setup mode by touching the keyboard.
This lock can only be re-added after the current administrator has deleted the
lock. The operation of deleting the lock needs to be done by Bluetooth beside
the lock.
Lock adding
The App supports multiple types of locks, including door locks, padlocks, safe locks, smart lock cylinders, parking locks, and bicycle locks. When adding a device, you must first select the lock type. The lock needs to be added to the app after entering the setting mode. A lock that has not been added will enter the setting mode as long as the locking keyboard is touched. The lock that has been added needs to be deleted on the App first.
The initialization data of the lock needs to be uploaded to the network. The data needs to be uploaded when the network is available to complete the entire whole adding process.
Lock upgrading
User can upgrade the lock hardware on the APP. The upgrade needs to be done via Bluetooth next to the lock. When the upgrade is successful, the original key, password, IC card, and fingerprint can continue to be used.
Error diagnosis and time calibration
Error diagnosis aims to help analyze the system problems. It needs to be done via Bluetooth beside the lock. If there is a gateway, the clock will be calibrated firstly through the gateway. If there is no gateway, it needs to be calibrated by the mobile phone Bluetooth.
Authorized administrator
Only the administrator can authorize the key. When the authorization is successful, the authorized key is consistent with the administrator’s interface. He can send keys to others, send passwords, and more. However, the authorized administrator can no longer authorize others.
Key management
After the administrator successfully adds the lock, he owns the highest administrative rights to the lock. He can send keys to others. Meanwhile, he can increase the key management that is about to expire..
Click the type of lock it will show the time-limited ekey, one-time key and permanent key. Time-limited ekey: The key is valid for the specified time Permanent key: The ekey can be used permanently. One-time key: the key will be automatically deleted once it has been used.
Key management
The manager can delete the key, reset the key, send and adjust the key, meanwhile he can search the lock record.
Deadline warning
The system will show two colons for deadline warning. The yellow means close to expiring and the red means it has expired.
Search lock record
The administrator can query the unlock record of each key.
Passcode management
After inputting the passcode on the keyboard of the lock, press the unlock button to unlock. Passcodes are classified into a permanent, time-limited, one-time, empty, loop, custom, etc.
Permanent passcode
The permanent passcode must be used within 24 hours after it is generated, otherwise, it will automatically expire.
Time-limited passcode
The time-limited passcode can own an expiration date, which is a minimum of one hour and a maximum of three years. If the validity period is within one year, the time can be accurate to the hour; If the validity period is more than one year, the accuracy Is month. When the time-limited passcode is valid, it should be used within 24 hours, otherwise, it will automatically expire.
One-time passcode
One-time passcode can only be used for one time and is available for 6 hours.
Clear code
Clear code is used to delete all the passcodes the lock has set, which is available for 24 hours.
Cyclic passcode
The cyclic password can be reused within a specified time period, including daily type, weekday type, weekend type, and more.
Custom passcode
User can set any passcodes and validity period he wants.
Passcode sharing
The system adds new communication ways of Facebook Messenger and Whatsapp to help users share the passcode.
Passcode management
All generated passcodes can be viewed and managed in the password management module. This includes the right of changing the password, delete the password, reset the password, and unlock the password.
Card management
You need to add the IC card first. The whole process needs to be done via the
app besides the lock. The validity period of the IC card can be set, either
permanent or time-limited.
All IC cards can be queried and managed through the IC card management module.
The remote card issuance function is displayed in the case of a gateway. If
there is no gateway, the item is hidden.
Fingerprint management
Fingerprint management is similar to IC card management. After adding a fingerprint, you can use the fingerprint to unlock the door.
Unlock via Bluetooth
App Users can lock the door via Bluetooth and can also send the Bluetooth key
to anyone. Unlock by App
Click the round button at the top of the page to unlock the door. Since the
Bluetooth signal has a certain coverage, please use the APP within a certain
area.
Attendance management
The APP is access control, which can be used for company attendance management. The app contains functions of employee management, attendance statistics, and so on. All 3.0 door locks have attendance functions. The normal door lock attendance function is turned off by default. The user can turn it on or off in the lock settings.
System setting
In the system settings, it includes touch unlock switch, group management,
gateway management, security settings, reminder, transfer smart lock, and so
on.
Touch unlock setting determines whether you can open the door by touching the
lock.
User management
The user name and phone number can be seen in the user list. Click the customer you want to view to get the door lock information.
Key groups management
In the case of a large number of keys, you can use a group management module.
Transfer admin rights
The administrator can transfer the lock to other users or to the apartment
(Room Master user). Only the account that manages the lock has the right to
transfer the lock. After inputting the account, you will receive a
verification code. Filling in the correct number, you will transfer
successfully.
The account of the apartment transfer received must be the administrator
account.
Lock recycling station
If the lock is damaged and cannot be deleted, the lock can be deleted by moving it into the recycling station.
Customer service
The user can consult and give feedback through the Al customer service
About
In this module, you can check the app version number.
Gateway management
The Smart lock is directly connected via Bluetooth, that is why it is not attacked by the network. The gateway is a bridge between smart locks and home WIFI networks. Through the gateway, the user can remotely view and calibrate the lock clock, read the unlock record. Meanwhile, it can remotely delete and modify the password.
Gateway adding
Please add the gateway via APP:
A Connect your phone to the WIFI network to which the gateway is connected to.
B Click the plus button in the upper right corner and input the WIFI passcode
and gateway name. Click OK and input the passcode for authentication.
C Press and hold the setting button on the gateway for 5 seconds. The green
light indicates that the gateway has entered the add-on mode.
Manual
After a short period of time, you can see which locks are in their coverage in the app. Once the lock is bound to the gateway, the lock can be managed through the gateway.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
This device and its antenna(s) must not be co-located or operated in
conjunction with any other antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1)This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. This equipment
complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum
distance of 20cm between the radiator and your body.