Xiaomi LS5 MiHome Duka Laser Meter with Touch OLED Display Instruction Manual
- June 6, 2024
- Xiaomi
Table of Contents
Product Overview
Main parameters
Product Type | Portable Laser Rangefinder |
---|---|
Unit | m/in/ft |
Operating temperature | -10°C-40°C |
Storage temperature | -20°C-60°C |
Continuity | 280mAh Approx 4000 measurements |
Measurement Range | Laser0.03-40m’* |
Laser Type | 620~670nm,<1mw Class 2 |
Charging method | DC 5V <2A adaptive |
- The number of measurements is obtained based on the laboratory environment (5 meters distance, 300LX brightness).
The actual number of daily measurements will have a deviation of about plus or minus 500 times.
Technical Data
Measurement Range
(General Conditions)| Laser 0.03-40m
---|---
Measurement Range
(x Unfavorable conditions| Laser 0.03-40m
Measurement accuracy
(General Conditions)| +2mm
Measurement accuracy
(Unfavorable conditions)| Laser+5mm
Maximum relative air humidity| 80%
Minimum display unit.| 1mm
- General conditions: strong reflectivity in the laser/infrared irradiated area (e.g. painted white walls), dark background lighting and operating temperature of 15°C-35°C. At this point it is important to consider An error effect of plus or minus 0.05 mm/m.
- Unfavorable conditions: weak reflectivity of laser irradiated area {such as black cardboard, polished tiles), strong background illumination and an operating temperature of <-10°C or >45°C. At this time to consider a plus or minus 2 mm / m error impact.
Suggestions on how to operate
- Laser distance measurement, in order to ensure the accuracy of the measurement, the rangefinder needs to remain stationary. When the hand is shaking, the data error is very large, and nay not be able to obtain data.
- Please avoid blocking the light-emitting port and receiving lens when measuring.
- Based on physical principles, when measuring on some specific object surfaces errors can occur, for example transparent surfaces (water, glass), surfaces that reflect surfaces (polished metals), porous surfaces (e.g. soundproof materials)If necessary, reflective target paper (e.g. white paper} can be placed on top of these objects.
Operation method
On/Off.
Long press the screen 3 seconds to turn on| Long press for 5 seconds and then
shut down 50 seconds without operation automatically shut down
---|---
Measurement function
switching. Swipe the screen left and right to switch between
measurement functions
Switching the measurement reference.
Swipe the screen up and down to switch to reference measurement mode.
Swipe up and down the screen: Switching front/back reference
- Front/Back reference: means whether the body length is counted in the measurement data of both ways. Front datum: Without fuselage length. Back reference: Include fuselage length.
Straight-line measurement.
Click on the screen and measure the data| Continuous measurement.
In this mode, the measured data, the The system auto matically displays the measured data Maximum and minimum values
---|---
|
Advanced measurement function description
A. Area measurement
In this mode, the area can be measured and automatically calculated by
clicking the screen to get the data 1, and then click again to get the data 2
The system automatically calculates the area data.
B. Volumetric measurement
In this mode, the volume can be measured and automatically calculated by
clicking the screen to get the data 1), click again to get the data 2, click
again to get the data 3, the system automatically measures the volume data
C. Primary Pythagorean/Secondary Pythagorean measurement (indirect
measurement)
In this mode, the system uses the Pythagorean law a²+b²=c² The third side
measurement data is automatically measured by the two side measurement data
-
One Pythagoras
-
Quadratic Pythagoras (data subtraction)
D. One-click angle height measurement
In this mode, click on the screen to get the data 1, click again to get Data 2
The system automatically calculates the angle data
E. Horizontal measurement
In this mode, the system uses the body gyroscope sensor Real-time measurement
of the body angle
Screen display description
Setting Mode
Setting mode entry method.
Slide left and right to the settings screen The interface shows click to enter
the detailed settings page
Basic operating logic.
Swipe up and down the screen to switch settings options Swipe the screen left
and right to adjust the setting content Click on the screen to save the
settings and return to the main screen
Setup Page 1: Accuracy Adjustment
Calibration of product accuracy within 10mm
Setup Page 2: Switch LS-5 default measurement unit
On this setting screen, change the measurement unit of LS-5.
Settings Page 3: Adjust the backlight time to save power
In this setting page, you can set the screen no operation under the
backlight time
Setup Page 3: Toggle speaker sound switch
In this setting page, you can set the speaker sound switch
Setup Page 3: LS-5 for calibration reference
In this setting page, you can correct the base
Problems and Solutions
Fault Type | Possible causes and solutions |
---|---|
Unable to turn on | 1. No battery power, charge and then try to turn on 2. |
Long press the switch time is not enough, please confirm Press for 1 second 3.
Other quality problems, please contact the dealer to solve.
No display| 1. No battery power, try to turn on after charging. 2. The
display is damaged, please contact the dealer to solve.
Large error| 1. Add white reflector for harsh environment.
2. Fix calibration accuracy in setting page
Unable to charge| 1. The charging cable is damaged, replace the charging
cable to try to solve 2. The charging module is damaged, please contact the
after-sales service to solve
Error code D.E| Measuring distance too close, too far or Pythagorean
measurement error
Error code T.L/T.H| The ambient temperature is too low/high, please warm
up/cool down the equipment
No data| 1. Laser receiving / transmitting head defacement, clean treatment
2. Rangefinder shake too much, please rest
Instructions for use
Be sure to read all the terms and operating instructions in this manual before using the product. Failure to follow these safety provisions and operating instructions may result in dangerous laser radiation injuries.
It is strictly forbidden to change the performance of the laser, as this can lead to laser exposure causing danger. lt is strictly forbidden to look directly at the laser. Please keep your instrument in a safe place to avoid the use of unrelated persons.
- Do not intentionally irradiate others with the laser.
- Do not shine the laser beam on objects with highly reflective surfaces.
- Please place it in an area out of the reach of children.
- Infrared light source for ordinary LED lamp beads, will not cause any harm to the person. However, prolonged direct vision will lead to brief eye discomfort.
Donot repair this instrument without permission. If the instrument is damaged,
please contact your local dealer.
Electromagnetic radiation may cause interference to its ground equipment and
devices (e.g., pacemakers, etc.}.
- Do not use this instrument in a flammable or explosive environment.
- Do not use this instrument near medical equipment.
- Do not use this instrument onboard an aircraft.
Please dispose of disused instruments in accordance with the laws of your location.
Class || Safety Laser
But it is strictly prohibited to
shoot directly into the eyes
- Due to continuous improvement and upgrading of products, the Company reserves the right to modify this manual without prior notice to the public.
- All text descriptions and patterns in this manual are protected by copyright and other laws Reproduction, extraction and modification are strictly prohibited, and infringement will be investigated.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>