Function introduction
- Dimmable LED driver with DALI/Push/Triac/1-10V dimming interfaces
- In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2.
- Built-in DALI-2 interface, DALI DT6 device
- 1 channel constant current output, max. output power 38W
- Output current 350-1000mA selectable by DIP switch
- Enables to control single color LED lighting
- Class Ⅱ power supply, full isolated plastic case
- High power factor and efficiency
- Compatible with universal DALI masters that support DT6 commands
- Compatible with universal Triac dimmers
- Compatible with universal 0/1-10V dimmers
- Amplitude dimming (PWM dimming under 10%), deep and smooth dimming to 0.1%, flicker free
- IP20 rating, suitable for indoor LED lighting applications
- 5 years warranty
Dips to set the operation current
!! Always switch off the power before changing the dip switches !!
Settings for Integratech QT/QTU/BRIGHT panel series
- 30W:750mA
- 36W:900mA
Settings for Integratech MANGA U panel series
- 30W:750mA
- 36W:900mA
- 38W:1000mA
Toolless connection range: 0,75~2,5 mm²
Product Data
Output
| LED Channel| 1
---|---|---
Selectable Current| 350mA| 400mA| 450mA| 500mA| 550mA| 600mA| 650mA
DC Voltage Range| 8-57V| 8-57V| 8-57V| 8-57V| 8-57V| 8-57V| 8-57V
Selectable Current| 700mA| 750mA| 800mA| 850mA| 900mA| 950mA| 1000mA
DC Voltage Range| 8-54V| 8-50V| 8-47V| 8-44V| 8-42V| 8-40V| 8-38V
Current Accuracy| ±3%
Rated Power| 5-38W
Input
| Voltage Range| 220-240V AC
Frequency| 50/60Hz
Power Factor (Typ.)| >0.95
Efficiency (Typ.)| > 85% @ 230VAC
Input Current| 210mA @ 230VAC
Inrush Current (Typ.)| COLD START Max. 2A @ 230VAC
Control
| Dimming Interface| DALI (DALI consumption<2mA)/Push+Triac+0/1-10V
Dimming Range| 0.1%-100%
Dimming Method| Amplitude dimming (PWM dimming under 10%)
Protection
| Short Circuit| Yes, auto recovery after fault removed
Over Current| Yes, auto recovery after fault removed
Over Temperature| Yes, auto recovery after fault removed
Environment
| Working Temp.| -20℃ ~ +45℃
---|---|---
Max. Case Temp.| 85℃ (Ta=45℃)
Working Humidity| 10% ~ 95% RH non-condensing
Storage Temp. & Humidity| -40℃ ~ +80℃, 10% ~ 95% RH
Safety&EMC
| Safety Standards| EN61347-1, EN61347-2-13
Withstand Voltage| I/P-O/P: 3.75KVAC
EMC Emission| EN55015, EN61000-3-2, EN61000-3-3
EMC Immunity| EN61547, EN61000-4-2,3,4,5,6,8,11, surge immunity Line-Line 1KV
Others
|
MTBF
| 188600H, MIL-HDBK-217F @ 230VAC at full load and 25℃ ambient temperature
Dimension| 1705929mm (LWH)
Operation
Dimming Interface Selection
- The LED driver supports 4 kinds of dimming input: DALI, Push, Triac, 0/1-10V.
- Please select any of the 4 dimming interfaces to wire each time.
- To connect a new dimming interface, previously connected dimming interface must be disconnected.
- DO NOT connect more than 2 (including 2) dimming interfaces simultaneously.
DALI Address Assigned by DALI Masters
While connected with DALI interface, 1 DALI address can be assigned by DALI
Master controller automatically, please refer to user manuals of compatible
DALI Masters for specific operations.
PUSH Dimmer Mode
While connected with a AC PUSH, the driver will be in Push Dimmer Mode,
operations under Push Dimmer Mode are as follows:
- Click the button to switch ON/OFF
- Press and hold down the button to increase or decrease light intensity to desired level and release it, then repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%.
- Memory function after power off or power failure enables the device to memorize the status before power off while power on again.
Triac Dimming Input
While connected with a Triac dimmer, different Triac dimmers from different
suppliers may have different minimum dimming levels which the driver can not
be dimmed below. To dim to 1%, please make sure the dimmer supports 1% minimum
dimming level.
Wiring Diagram
With DALI bus L N