Overview
The MGate MB3170 and MB3270 are 1 and 2-port advanced Modbus gateways that convert between Modbus TCP and Modbus ASCII/RTU protocols. They can be used to allow Ethernet masters to control serial slaves, or to allow serial masters to control Ethernet slaves. Up to 32 TCP masters and slaves can be connected simultaneously. The MGate MB3170 and MB3270 can connect up to 31 or 62 Modbus RTU/ASCII slaves, respectively.
Package Checklist
Before installing the MGate MB3170 or MB3270, verify that the package contains the following items
- MGate MB3170 or MB3270 Modbus gateway
- Quick installation guide (printed)
- Warranty card
Optional Accessories
- DK-35A: DIN-rail mounting kit (35 mm)
- Mini DB9F-to-TB Adaptor: DB9 female to terminal block adapter
- DR-4524: 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
- DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
- DR-120-24: 120W/5A DIN-rail 24 VDC power supply with 88 to 132 VAC/176 to 264 VAC input by switch
Hardware Introduction
LED Indicators
Name | Color | Function |
---|---|---|
PWR1 | Red | Power is being supplied to the power input |
PWR2 | Red | Power is being supplied to the power input |
RDY
| ****
Red
| Steady: Power is on and the unit is booting up
Blinking: IP conflict, DHCP or BOOTP server did not
respond properly, or a relay output occurred
Green
| Steady: Power is on and the unit is functioning
normally
Blinking: Unit is responding to locate function
Off| Power is off or power error condition exists
Ethernet
| Amber| 10 Mbps Ethernet connection
Green| 100 Mbps Ethernet connection
Off| Ethernet cable is disconnected or has a short
P1, P2
| Amber| Serial port is receiving data
Green| Serial port is transmitting data
Off| Serial port is not transmitting or receiving data
FX
| ****
Amber
| Steady on: Ethernet fiber connection, but port is
idle.
Blinking: Fiber port is transmitting or receiving
data.
Off| Fiber port is not transmitting or receiving data.
Reset Button
Press the Reset button continuously for 5 sec to load factory defaults:
The reset button is used to load factory defaults. Use a pointed object such
as a straightened paper clip to hold the reset button down for five seconds.
Release the reset button when the Ready LED stops blinking.
Panel Layouts
The MGate MB3170 has a male DB9 port and a terminal block for connecting to serial devices. The MGate MB3270 has two DB9 connectors for connecting to serial devices.
Hardware Installation Procedure
STEP 1: After removing the MGate MB3170/3270 from the box, connect the
MGate MB3170/3270 to a network. Use a standard straight-through Ethernet
(fiber) cable to connect the unit to a hub or switch. When setting up or
testing the MGate MB3170/3270, you might find it convenient to connect
directly to your computer’s Ethernet port. In this case, use a crossover
Ethernet cable.
STEP 2: Connect the serial port(s) of the MGate MB3170/3270 to a serial
device.
STEP 3: The MGate MB3170/3270 is designed to be attached to a DIN rail or
mounted on a wall. The two sliders on the MGate MB3170/3270 rear panel serve a
dual purpose. For wall mounting, both sliders should be extended. For DIN-rail
mounting, start with one slider pushed in, and the other slider extended.
After attaching the MGate MB3170/3270 on the DIN rail, push the extended
slider in to lock the device server to the rail. The two placement options are
illustrated in the accompanying figures.
STEP 4: Connect the 12 to 48 VDC power source to terminal block power
input. Connect the 12 to 48 VDC power source to terminal block power input.
Wall or Cabinet Mounting
Mounting the MGate MB3170/3270 Series on to a wall requires two screws. The
heads of the screws should be 5 to 7 mm in diameter, the shafts should be 3 to
4 mm in diameter, and the length of the screws should be more than 10.5 mm.
NOTE Wall mounting is certified for use in maritime applications.
Software Installation Information
ou can download the MGate Manager, User’s Manual, and Device Search Utility (DSU) from Moxa’s website: www.moxa.com. Please refer to the User’s Manual for additional details on using the MGate Manager and DSU.
- The MGate MB3170/3270 also supports login via a web browser.
- Default IP address: 192.168.127.254
- Default account: admin
- Default password: moxa
Pin Assignments
Ethernet Port (RJ45)
Serial Port (DB9 Male)
Terminal Block Female Connector on the MGate (RS-422, RS-485)
Power Input and Relay Output Pinouts
Optical Fiber Interface
| 100BaseFX
---|---
Multi-mode| Single-mode
Fiber Cable Type| OM1| 50/125 μm| G.652
*800 MHzkm**
Typical Distance| 4 km| 5 km| 40 km
Wave- length| Typical (nm)| 1300| 1310
TX Range (nm)| 1260 to 1360| 1280 to 1340
RX Range (nm)| 1100 to 1600| 1100 to 1600
Optical Power
| TX Range (dBm)| -10 to -20| 0 to -5
RX Range (dBm)| -3 to -32| -3 to -34
Link Budget (dB)| 12| 29
Dispersion Penalty (dB)| 3| 1
Note: When connecting a single-mode fiber transceiver, we recommend using an
attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as
follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).
Specifications
Power Requirements
Power Input| 12 to 48 VDC
Power Consumption (Input Rating)| • MGate MB3170, MGate MB3170-T, MGate
MB3270, MGate MB3270-T:
12 to 48 VDC, 435 mA (max.)
• MGate MB3270I, MGate MB3270I-T, MGate MB3170-M-ST, MGate MB3170-M-ST-T, MGate MB3170-M-SC, MGate
MB3170-M-SC-T:
12 to 48 VDC, 510 mA (max.)
• MGate MB3170I, MGate MB3170I-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, MGate MB3170I-S-SC, MGate
MB3170I-S-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T:
12 to 48 VDC, 555 mA (max.)
Operating Temperature| 0 to 60°C (32 to 140°F),
-40 to 75°C (-40 to 167°F) for –T model
Storage Temperature| -40 to 85°C (-40 to 185°F)
Operating Humidity| 5 to 95% RH
Magnetic Isolation
Protection (serial)
| 2 kV (for “I” models)
Dimensions
Without ears: With ears extended:
| ****
29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.9 in)
Relay Output| 1 digital relay output to alarm (normal close):
current carrying capacity 1 A @ 30 VDC
Hazardous Location| UL/cUL Class 1 Division 2 Group A/B/C/D, ATEX
Zone 2, IECEx
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
ATEX and IECEx Information
MB3170/3270 Series
-
Certificate number: DEMKO 18 ATEX 2168X
-
IECEx number: IECEx UL 18.0149X
-
Certification string: Ex nA IIC T4 Gc
Ambient Range : 0°C ≤ Tamb ≤ 60°C (For suffix without -T) Ambient Range : -40°C ≤ Tamb ≤ 75°C (For suffix with -T) -
Standards covered:
ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4 -
The conditions of safe usage:
- The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
- The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP4 in accordance with IEC/EN 60079-0.
- Conductors suitable for Rated Cable Temperature ≥ 100°C
- Input conductor with 28-12 AWG (max. 3.3 mm2) to be used with the devices
MB3170I/3270I Series
-
ATEX Certificate number: DEMKO 19 ATEX 2232X
-
IECEx number: IECEx UL 19.0058X
-
Certification string: Ex nA IIC T4 Gc
Ambient Range : 0°C ≤ Tamb ≤ 60°C (For suffix without -T) Ambient Range : -40°C ≤ Tamb ≤ 75°C (For suffix with -T) -
Standards covered:
ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4 -
The conditions of safe usage:
- The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
- The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with IEC/EN 60079-0.
- Conductors suitable for Rated Cable Temperature ≥ 100°C
- Input conductor with 28-12 AWG (max. 3.3 mm2) to be used with the devices
Address of manufacturer: No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004, Taiwan
References
Read User Manual Online (PDF format)