SOLiD EROU67835L2 DAS System User Manual
- June 6, 2024
- SOLiD
Table of Contents
SOLiD EROU67835L2 DAS System
REVISION HISTORY
Version
| ****
Issue Date
| No. of Pages| ****
Initials
| ****
Details of Revision Changes
---|---|---|---|---
V 1.0| February 05, 2021| | Original|
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
Technical Support
SOLiD serial numbers must be available to authorize technical support and/or
to establish a return authorization for defective units. The serial numbers
are located on the back of the unit, as well as on the box in which they were
delivered. Additional support information may be obtained by accessing the
SOLiD Tehcnology, Inc. website at www.solid.co.kr or
send an email at sjkim@solid.co.kr
This manual is produced by Global Business Division Business Team Printed in
Korea.
Safety & Certification Notice
“Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.”
- Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
- The power supply unit in repeaters contains dangerous voltage levels, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.
- your equipment is exclusive to the indoor.
- Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.
- Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 70 cm minimum clearance from the antenna while the system is operating.
- Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation.
- Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors.
- To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm.
- Do not look into the ends of an optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure.
- Allow sufficient fiber length to permit routing without severe bends.
- For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible.
- A readily accessible disconnect device shall be incorporated external to the equipment.
- This power of this system shall be supplied through wiring installed in a normal building.
- If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device
- Only 50 ohm rated antennas, cables, and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device.
- Only 50 ohm rated antennas, cables, and passive components operating from 150 – 3 GHz shall be used with this device.
- The head-end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station.
- Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and
- Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location.
- Notice! Be careful not to touch the Heat-sink part due to high temperature.
WARNINGS
Signal booster warning label message should include
Certification
- FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15, 22, 27 and 90(Class B)
- Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited.
- Home/ personal use are prohibited.
- UL/CUL: This equipment complies with UL and CUL 62368-1 Standard for safety for information technology equipment,including electrical business equipment
- FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040
- IC Booster warning label message should include
WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device.
System configuration and Functions
eROU(edge Remote Optic Unit)
eROU receives TX optical signals from eHUB and converts them into RF signals.
The converted RF signal is radiated to the antenna port via the AMP and
Multiplexer.
When receiving RX signals through the antenna port, this unit filters out-of-
band signals in a corresponding Multiplexer and sends the results to OPTIC to
make electronic-optical conversion of them. After converted, the signals are
sent to an upper device of eHUB.
The eROU supports up to 4 bands.
In addition, if band extension is required, another era can be added up to
three using optical splitters and RF ports. However, the band expansion
equipment will be developed in the future.
And eROU is divided into an Internal product with an antenna and an External
product without an antenna. (*Note: External product(Model name:
eROU_67835L2_X
Specifications of eROU
Item
| Spec.| ****
Remark
---|---|---
eROU
The rated mean output Power per band
| 600| +17dBm|
700LTE_FN| +17dBm
850IC| +17dBm
The nominal downlink bandwidth
| 600| 35MHz|
700LTE_FN| 39MHz
850IC| 32MHz
The nominal uplink bandwidth
| 600| 35MHz|
700LTE_FN| 38MHz
850IC| 32MHz
The nominal passband gain
| ****
Downlink
| 600| 37dB| ****
w/ iBIU and eHUB
700LTE_FN
| ****
37dB
850IC
| ****
37dB
Uplink
| 600| 47dB| ****
w/ iBIU and eHUB
700LTE_FN| 47dB
850IC| 47dB
Input/ Output Impedance| 50 ohm|
---|---|---
Weight
| N.A| ****
Common Part
3.0 kg(d)
Power consumption| 35W
Temperature range| -5°C to +50°C| Ambient Temperature
Humidity Range| 5% ~ 90%| Non-condensing
Sealing (Remote Unit)| IEC/UL/CSA 62368-1|
Size(mm)
| 220 x 220 x 65| Integrated Antenna
200 x 200 x 45| External Antenna
Port on eROU
Functions
No | Port | Quantity | Remark |
---|---|---|---|
1 | Optical Port | 1EA | LC/APC |
2 | ANTENNA PORT(External Only) | 2EA | 2.2-5 type female |
3 | Power IN | 1EA | Terminal_Block_CONN_2P(TLPS-302V-02P-G) |
4 | ADD ON eROU Port | 2EA | QMA-type female |
5 | ADD ON eROU Port | 1EA | RJ45 |
6 | USB Port | 1EA | USB-C Type |
RSS-GEN (transmitters)
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
(The antenna is not supported with this model. So, The antenna must not exceed
Max. Gain 17dBi, to comply with IC regulation.)
RF Radiation Exposure
This equipment complies with RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 70 cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter. RF exposure will be addressed at time of installation
and the use of higher gain antennas may require larger separation distances.
FCC Part 15.105 statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
FCC Part 15.21 statement
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
RF Exposure Statement
The antenna(s) must be installed such that a minimum separation distance of at
least 70 cm is maintained between the radiator (antenna) and all persons at
all times. This device must not be co-located or operating in conjunction with
any other antenna or transmitter.
System Installation
ROU Installation
eROU Enclosure installation
The eROU can be mounted on a wall or ceiling.
and divided into the version of External Antena and the version of Internal
Antena.
eROU appearance (Left : External Antenna, Right : Internal Antenna)
eROU(Internal Antenna) Mount Installation_ Case .1
eROU(Internal Antenna) Mount Installation_ Case .2
error(Internal Antenna) Mount Installation_ Case .3
eROU(External Antenna) Mount Installation
Installation Cable Gland
eROU
Combine of eROU and cROU
Power cabling
- The eROU receives DC power from the eHub or external adapter.
- The cable length between eHub and even supports up to 2.4 km.(Cable specifications recommend AWG14.)
- If the maximum length between the eHub and the eROU is exceeded, the use of the External Adapter is recommended.
The adaptor is extra purchase. Specified below shall be used only adapter.
There are no hot-swap functions. Please turn off the HSDB port (refer to below)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>