WIRING INSTRUCTIONS
Submersible Well Pump
220V/60Hz
ATTENTION:
BLACK – HOT WIRE (110V),
BLUE – HOT WIRE (110V) ,
YELLOW – GROUND WIRE (PE).
Splice Kit:
A: Black Heat Shrink Tubing | B:White Heat Shrink Tubing | C: Butt Connector |
---|---|---|
D: Rubber Splicing Tape | E: Hot Melt Adhesive | F: Waterproof Electrical Tape |
ATTENTION:
BLACK – HOT WIRE (110V), BLUE – HOT WIRE (110V) , YELLOW – GROUND WIRE (PE).
Extension Cord Recommendations:
HP| Cable Length(ft)| 3-52 ft| 53- 98 ft| 99- 148 ft| 149- 197 ft| 198- 246
ft| 247- 295 ft
---|---|---|---|---|---|---|---
1 HP| Wire Size (AWG)| 18| 17| 16| 16| 15| 15
2 HP| Wire Size (AWG)| 16| 15| 14| 14| 13| 13
Ref. accessory numbers A, B, C, D, E & F on prev. page of splice kit.
****Match Each Other Correctly
- Place B over each individual wire.
- Firmly crimp each splice with crimping plier.
- Heat B with a heat gun or lighter.
- Wind D on the butt splice connections.
- Wrap the three wires together with E.
- Slide A over the connection and evenly heat it on all sides.
- Wind F over the shrink tubing A and cable.
CAUTION
- The pump’s voltage must match your power supply.
- Please install external check valves at the discharge to prevent flowback.
- The pump must be installed in a 4″ or larger well casing with torque arrestors.
- Please don’t run the pump dry. Make sure it is fully submerged in water.
- The pump is designed for clean water. Please make sure all fines and foreign matters in the well are removed before installation.
- Please keep the pump at least 10ft from the bottom of well,and above the well screen or casing perforations.
For more information on installation, please read the user manual.