JDE002136 Dehumidifier
Instruction Manual Please
read this manual carefully before use and keep it for further reference.
BEFORE YOU BEGIN
PRODUCT DESCRIPTION
The dehumidifier is used to remove excess moisture from the air. The resulting
reduction in relative humidity protects buildings and their contents from the
adverse effects of excess humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse effect
(GWP), and is available worldwide. Because of its efficient energy properties,
R290 is highly suitable as a coolant for this application. Special precautions
must be taken into consideration due to the coolant’s high flammability.
1.2SYMBOLS FROM THE UNIT AND USER MANUAL
| This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will
create harmful gas and there is a risk of fire.
---|---
| Read the USER MANUAL carefully before operation.
| Further information is available in the USER MANUAL, SERVICE MANUAL, and the
like.
| Service personnel are required to carefully read the USER MANUAL and SERVICE
MANUAL before operation.
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
- This appliance is intended to be used by expert users in electronic products. Repair can only be made by Qualified Technician.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
- The refrigerant loop is sealed. Only a qualified technician should attempt to service!
- Do not discharge the refrigerant into the atmosphere.
- R-290 (propane) is flammable and heavier than air.
- It collects first in low areas but can be circulated by the fans.
- If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
- The propane gas used in the unit has no odor.
- The lack of smell does not indicate a lack of escaped gas.
- If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
- Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the store.
- No open flames, cigarettes, or other possible sources of ignition should be used inside or in the vicinity of the units.
- Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
SAFETY
Your safety is the most important thing we are concerned!
Please read this manual carefully and fully understand before operating your dehumidifier.
OPERATIONALPRECAUTIONS
WARNING- To reduce the risk of fire, electric shock, or injury to persons
or property:
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
- The A-weighted sound pressure level is below 45 dB.
- The appliance shall be disconnected from its power source during maintenance.
- Always operate the unit from a power source of equal voltage, frequency, and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
- Do not operate with wet hands. Prevent water from spilling onto the unit.
- Do not immerse or expose the unit to rain, moisture, or any other liquid.
- Do not leave the unit running unattended. Do not tilt or turn over the unit.
- Do not unplug while the unit is operating.
- Do not unplug by pulling on the power cord.
- Do not use an extension cord or an adapter plug.
- Do not put objects on the unit.
- Do not climb or sit on the unit.
- Do not insert fingers or other objects into the air outlet.
- Do not touch the air inlet or the aluminum fins of the unit.
- Do not operate the unit if it is dropped, damaged, or showing signs of product malfunction.
- Do not clean the appliance with any chemicals.
- Ensure the unit is far away from fire, inflammable, or explosive objects.
- The unit shall be installed in accordance with national wiring regulations.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuous operation sources (for example open flames, an operating gas appliance, or an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Do not pierce or burn, even after use.
- Be aware that refrigerants may not contain an odor.
- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space if that space is smaller than 12m².
- Compliance with national gas regulations shall be observed.
- Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
| Any person who is involved with working on or breaking into a refrigerant
circuit should hold a currently valid certificate from an industry-accredited
assessment authority, which authorizes their competence to handle refrigerants
safely in accordance with industry, recognized assessment specifications.
---|---
| Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
If you don’t understand something or need help, please contact the dealer services
SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a
dehumidifier with R290.
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For
repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the
risk of flammable gas or vapor being present while the work is being
performed.
General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of the work being carried out. Work in confined spaces shall be
avoided. The area around the workspace shall be sectioned off.
Ensure that the conditions within the area have been made safe by control of
flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e. no sparking, adequately sealed, or
intrinsically safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
to hand. Have a dry powder orCO2 fire extinguisher adjacent to the charging
area.
No ignition sources
No person carrying out work in relation to a refrigeration system that
involves exposing any pipework that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing, and disposal, during which
flammable refrigerant can possibly be released to the surrounding space. Prior
to work taking place, the area around the equipment is to be surveyed to make
sure that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult the
manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise the safety, then no electrical supply shall be connected to the
circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the
equipment so all parties are advised.
Initial safety checks shall include:
- those capacitors are discharged: this shall be done in a safe manner to avoid the possibility of sparking;
- that there no live electrical components and wiring are exposed while charging, recovering, or purging the system;
- that there is continuity of earth bonding.
USING THE APPLIANCE WITH SECURITY
- Install the unit on flat and hard floor to diminish vibration or noise.
- Never immerse the unit in water or other liquids.
- Never operate the unit if the cable or other connector is damaged, or something abnormal may happen, please call customer service for help.
- Disconnect the unit from the power supply when it is not in use, or before relocating or cleaning it.
- Operate the unit only at the voltage specified.
- The unit is for indoor use only. Don’t use it for another purpose.
- Do not put heavy objects on the appliance.
- Do not tip the unit to any side as spilled water could damage the appliance.
- Never insert any other object into the unit body to avoid any hazard or unit failure.
- Do not put the unit close to heat-generating devices or near flammable and dangerous materials.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent, or a similarly qualified person in order to avoid a hazard.
- The appliance must be positioned so that the plug is accessible.
- The appliance shall be installed in accordance with national wiring regulations.
- The ambient temperature range for the appliance is 5-35 ℃.
Don’t try to repair, dismantle or remold such appliance, or it may make some damage. Even the change of power cord should be done by a specially qualified person.
SPECIFICATIONS
Model | JDE002136 |
---|---|
Dehumidify Capacity | 20L day (30°C.80%RH) |
Supply Voltage | 220-240V/50Hz |
Rated Input Power | 380W(30°C.80%RH) |
Rated Input Current | 2.0A(30°C.80%RH) |
Water Tank Capacity | 5.5L |
Sound Pressure Level | 545dB(A) |
Refrigerant Charge | R290/85g |
Product Dimension | H 587 x W 335 x 0240mm |
Net Weight | 15kg |
Suction Side Pressure | 0.7MPa |
Discharge Side Pressure | 3.2MPa |
APPLIANCE OVERVIEW
LOCATION
- Place the unit on a firm, level surface in an area with at least 20cm of free space around it to allow for proper air circulation.
- Never install the unit where it could be subject to :
➢ Heat sources such as radiators, heat registers, stoves, or other products that produce heat.
➢ In an area where oil or water may be splashed
➢ Direct sunlight
➢ Mechanical vibration or shock
➢ Excessive dust
➢ Lack of ventilation, such as cabinet or bookcase
➢ Uneven surface
| Install the unit in rooms that exceed 8 m².
Do not install the unit in a place where inflammable gas may leak.
---|---
| The manufacturer may provide other suitable examples or may provide
additional information about the refrigerant odor.
OPERATION INSTRUCTIONS
Instructions of indicator lights
| Power indicator: After plugging in, the power indicator shows green
whether the machine starts working or not.
---|---
| Water-full indicator: When the water tank is full, it shows red and the
unit will buzz for 5 times. At that time, the machine stops, and all the
buttons are locked unless users empty and recover the water tank.
| Timer indicator: When the timer function is working, the indicator
light shows green.
| Sleep indicator (Low fan speed): It shows green when the unit is
running at low fan speed.
TURBO| Turbo indicator (High fan speed): It shows green when the
unit is running at high fan speed.
| Drying clothes indicator: It shows green when the drying clothes
function is working. In that mode, the compressor works continuously without
the influence of room humidity. High fan speed is fixed and the humidity can’t
be adjusted.
| Clean filter indicator: After the accumulated running time reaches over
600 hours, this indicator will show red and the unit will buzz 20 times to
warn the user to change the filter. At that time, all the buttons are locked,
the compressor stops and the fan closes 60 seconds later. If the user wants to
cancel this warning, press the power button for 5 seconds, then the fan
running time resets to 0.
| Display: It has 3 functions as below:
1. When the power is on, it shows the room humidity;
2. When users adjust humidity, it shows the set humidity data;
3. When users set the timer on/off, it shows the timing data.
Instructions of Button Operation:
Power button: Press this button, the indicator light shows blue and the machine starts to work in normal mode with a default humidity setting of 50%RH and low fan speed. The fan starts working and the compressor will begin to work 3 seconds later. Press this button again, the compressor stops and the fan will close60 seconds later. All the indicators lights are off and it enters standby mode.
Timer button: Press this button to set timing from 0 to 24 hours in one- hour increments/decrements, along with the Add button and Minus button. When the machine is running, press this button to set the shutdown time; when it is in standby mode, press this button to set the startup time. If users want to cancel the timer setting, press the button until it shows 00 on the display.
Add and Minus button: (Timing and humidity setting):
The humidity adjustment is only effective in the normal mode. The initial
humidity is 50%. Press these two buttons to program room humidity from 20% to
80% in 5% increments or 5% decrease. When the set humidity value reaches one
end, press again and it will reset to the other end. If the indoor humidity is
lower than the set humidity, the machine stops automatically.
Fan speed button: Press this button to choose low fan speed(sleep) or
high fan speed(turbo).
Mode button: Press this button to choose normal or drying clothes mode.
SETTINGS
Operation mode setting
Normal Operation
Press the POWER key to turn on the unit.
The unit operates in normal mode with the default 50% humidity set-point.
The fan runs at Turbo speed by default.
Press the POWER key again to turn off the dehumidifier.
The fan keeps running for a while and then stops.
The display reads room relative humidity.
Drying Operation
Press the POWER key to turn on the unit.
Press the MODE key to activate the continuous drying mode.
The unit starts to dehumidify in continuous operation, regardless of the
humidity. The humidity set-point cannot be adjusted in this mode.
Press the MODE key again to deactivate the continuous drying mode.
Note: For continuous operation, the drain hose should be connected in
order to continuously drain the collected water.
Set Humidity (setting range: 20%-90%):
The humidity set-point can be adjusted in normal operation.
Press ADD/MINUS key repeatedly to adjust humidity set-point by increments of
5%. The unit will cycle on and off to maintain the level.
Set the humidity level between 40% and 60% for comfort.
Set Fan Speed:
Press the Fan key to switch the speed between Turbo and Sleep.
Note: The fan speed cannot be set when in defrosting progress.
Timer Setting (0 hour-24hours ):
The timer has two ways of operation:
Water FULL Indicator
The machine automatically shuts off once the water tank is full, alerting the
user through an indicator light and buzzing for 15 times. It reminds you to
check:
If the water tank is full, empty and re-install the water tank.
If the water tank is not in position, the full indicator is always on and the
unit is inoperative.
Re-install the tank correctly, and the unit will auto operate as your last
setting.
Room Temperature Inspection
In addition to the humidity level, the digital display can also indicate the
current room temperature. Please check as follows:
Press and hold the ADD/MINUS button for 5 seconds.
The screen displays the temperature in degrees Celsius for 5 seconds.
Auto Restart function
When there is a power outage, the dehumidifier automatically restarts when the
power comes back on and also resumes settings.
Automatic Defrost function
At low room temperatures (below 16 ℃), frost may build up at the evaporator
reducing the airflow across it during dehumidifying.
The dehumidifier will automatically start defrosting for 10 minutes.
The POWER LED blinking.
The compressor stops and the fan keeps running.
Do not turn off the unit and it will automatically restart dehumidifying.
Inspect air filter
The air filter requires regular cleaning. The inspect filter LED will light up
after every 600 hours accumulated operation reminding user to clean the
filter. The air filter is reusable and washable.
Press and hold the POWER button for 5 seconds to reset the filter inspection
LED.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute
delay until the compressor restarting
WATER DRAINAGE
Water Tank:
When the water tank is full, the water full indicator shows red to warn
that the tank has reached the maximal capacity.
How to empty the water tank:
-
Pull the water tank at the back of the machine slightly, the water tank is forced to move out.
-
Empty the water tank
Cautions! • Do not remove the float from the water tank; otherwise, the machine will not stop working when the water tank is full. Then the water will be overflow that maybe make damage to your floor.
• Drain the water completely when the water tank is full and reset your setting.
• If the water tank is dirty, clean it with cool or warm water. Don’t use cleaner, steel wool, chemical rag duster, gas oil, benzene, thinner, or another solvent to clean it, otherwise, it will damage the water tank and lead to leakage.
• Please use two hands to put the water tank into the machine correctly, or the water full indicator will still show red and the machine cannot work.
Continuous drainage
- Open the cover on the back of the dehumidifier
- Take out the water tank
- Insert a PVC pipe with 9.5mm (inner diameter 9.5mm), and the recommended length is 300mm; put the other side into a container, such as a bucket.
NOTE: PVC pipe is included in the package
Steps:
Securely and properly connect the drain hose and make sure it is not kinked
and clear of obstruction.
Place the outlet of the hose over a drain or bucket and ensure that water
could freely flow out of the unit.
Do not submerge the end of the hose into the water; otherwise, it can cause an
“Air Lock” in the hose.
To avoid water spillage:
As the negative pressure of the condensate drain pan is large, tilt the drain
hose down toward the floor.
It is appropriate that the degree of inclination should exceed 20 degrees.
Straighten the hose to avoid a trap existing in the hose
Caution:
- Never block the water outlet or the pipe, water will flow into the water tank if it is blocked.
- Never bend the drainage pipe and be always slower than the outlet.
- Must close the cover when no need for continuous drainage.
CLEANING AND MAINTENANCE
NOTE: TURN OFF THE UNIT AND UNPLUG IT BEFORE ANY MAINTENANCE OR REPAIR TO AVOID ELECTRIC SHOCKS.
Cleaning:
Unplug the unit before any cleaning. Do not sprinkle water on the unit.
Clean the housing with a soft wet cloth. Do not use chemical solvents such as
benzene, alcohol, gasoline, otherwise, the surface may be damaged or even the
whole case may be deformed.
Air filter:
The unit is equipped with a washable air filter. Clean the washable filter
every 2 weeks. If the filter is blocked with dust, the efficiency will reduce.
HOW TO CLEAN THE FILTER
-
Take out the filter
-
Clean the filter
Immerse it gently into warm water (about 40 ℃) with a neutral detergent and rinse it, then dry it thoroughly in a ventilated place.
Use the vacuum with its brush attachment to remove any dust. -
Assemble the filter:
Insert the filter back into the machine slowly
TROUBLESHOOTING GUIDE
BEFORE CALLING FOR SERVICE
This list includes common occurrences that are not the result of a defect in
workmanship or materials.
Problem | Possible Cause | Solution |
---|
The unit doesn’t
work| No power supply| Connect to a power outlet and switch on
Water kill indicator flashes| Drain the water tank and reset your setting, or
replace the water tank in the right place
Room temperature is under 5°C or above 35°C.| Self-protection is designed to
protect the unit, thus it can’t work under such temperature
Timer function is active.| Deactivate Timer function.
The
dehumidifying
function doesn’t
work or the unit
starts up/shuts
down frequently| Is the air filter clogged?| Clean the air filter
Is the door/window
opened?| Close the door/window
Is the unit close to any heat resource?| Remove the unit to a cool place
Is the intake duct or discharge duct obstructed?| Remove the obstruction from
the discharge duct or intake duct.
Operation is
noisy| Is the unit tilted or unsteady?| Place it on flat ground to achieve
less vibration.
Is the air filter clogged?| Clean the air filter
Error
code| E2| i Humidity sensor dampened or failure.| ;-. To clean or replace the
humidity sensor.
CL| ✓Display when the Room
temperature is below 5°C
C
( 41°F ) .| :- Normal. The compressor stops, and the fan keeps running.
CH| ✓Display when Room above35
temperature is t ( 95°F) .| : Normal. The compressor stops, and the fan keeps
running.
LO| ✓Display when Room relative humidity is below 20%RH.| : Normal. The
compressor stops, and the fan keeps running.
HI| ✓Display when Room relative humidity is above 950/011H.| : Normal. The
compressor and the fan keep running.
STORAGE
Long-term storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit as per the following steps:
- Press the power button to switch off and unplug the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Collect the power cord at the water tank.
- Re-install the filter at its position.
- The unit must be kept in an upright position when in storage.
- Preserving the machine in ventilating, dry, non-corrosive gas and safe place indoor.
ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.
DISPOSAL
WARNING!!!
Releasing refrigerant into the atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and wellbeing.
GENERAL WARRANTY TERMS
- The warranty is valid only on the presentation of the invoice of purchase.
- This WARRANTY is limited exclusively to parts substitution ineffective due to faulty manufacture, made in our workshops.
- The elimination of several faults of the scope of the guarantee is made for repair or replacement of defective parts, according to the discretion of our technical services. Defective parts are our property.
- Are not covered under warranty damage caused by transportation, neglect or poor use, improper assembly or installation, as well as external influences such as lightning strikes or power, flooding, humidity, etc.
- Lose warranty, all appliances that are not being used according to the instructions, or connected to FEEDING NETWORKS do not guarantee a constant voltage of 220/240V.
- The warranty does not cover damages for personal injury or damage caused directly or indirectly in any capacity whatsoever.
- This warranty terminates when it is found to have been undergoing repairs, alterations, or interventions by any person not authorized by Joel.
THE WARRANTY EXPIRES
- With the modification or disappearance of the nameplate of the appliance.
- Exceeded the period of 2 years for home appliances and 06 months for industrial appliances, the warranty expires and assistance will be made by charging the costs of manpower, according to current fees.
TECHNICAL ASSISTANCE
For technical assistance requests, our services are available through the
following contacts:
Telef. 00 351 252 910351
Fax: 00 351 252 910367
E-mail: assistencia@jocel.pt
http://www.jocel.pt
4780 –
382 Argemil, Santo Tirso
Porto, Portugal
Telef: 252 910 350
email: jocel@jocel.pt
http://www.jocel.pt
SEDE:
Rua Dos 5 Caminhos, nº516
DECLARATION OF CONFORMITY
We declare on our own responsibility that the machine indicated below:
Product DEHUMIDIFIER
Brand JOCEL
Model JDE002136
Complies with the following European directive and standards implementation:
Low Voltage 2014/35/EU
EN 60335-2-40:2003/A13:2012
EN 60335-1:2012/A11:2014
EN 62233:2008| Electromagnetic Compatibility 2014/30/EU
EN 55014-1:2017
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
---|---