Arenti Laxihub P2 Smart Pan Tilt Wi-Fi Camera User Guide

June 6, 2024
Arenti

Arenti Laxihub P2 Smart Pan Tilt Wi-Fi Camera User Guide

Packing list

Notice

To reset the device, press and hold the reset button for 5s. The camera beeps when the operation is complete.

Flashing red light (slow) Wait for network config
Flashing red light (fast) Connecting the network
Fixed red light Network is malfunctional
Fixed blue light Camera is working correctly

Installation

  1. LED indicator
  2. Microphone
  3. Speaker
  4. Reset button
  5. DC5V USB port
  6. Micro SD card slot

Notice

If you have multiple cameras, please follow step 5 again to add devices one by one.
To change the Wi-Fi network, please restore the camera to factory settings and follow step 5 to add the camera.

3. Installation

  1. Use the included mounting bracket to fix the camera to a clean surface

  2. Or, put the camera on a flat surface.

4. Camera configuration

Step 1 Turn on your camera by plugging in the power adaptor.
Step 2 Connect your smartphone to the Wi-Fi network.
Step 3 Download Arenti app from the App Store or Google Play depending on your device.
Step 4 Launch Arenti app and sign up for the first use.
Step 5 Follow the steps below to add your camera, then follow the on-screen instructions.
For more Information, scan the QR code below

https://www.arenti.com/blogs/help_center

Specifications

Sensor type 1/2.9″ CMOS
Min. brightness Color 0.01 Lux@F1.2
Black and white 0.001Lux@F1.2
Resolution 2 Mega pixels
Lens 3.6 mm F2.0
Shutter 1/25-1/100,000 per second
Infrared High power LED with ICR
Infrared distance 10 meters
Pan/Tilt 0°-355°/-43°-77°
Video compression H.264
Bit rate 32Kbps – 2Mbps
Max resolution 1920 x 1080
Framerate 1-25 per second
Picture settings Support HD/SD; support flip
Storage SD card (Max 256GB)
Audio Two-way audio
Protocols HTTP, DHCP, DNS, RTSP
WiFi standard IEEE802.11a/b/g/n
Frequency 2.4 GHz; 5 GHz
Bandwidth 20/40MHz
WiFi encryption WPA-PSK/WPA2-PSK
Security AES128
Working temperature -20°C-50°C
Power DC5V,1A
Consumption 4.5W MAX
Size(mm) 59 x 63 x 110

Adapter Specifications

Input voltage 100-240V AC
Input frequency 50-60Hz
Output voltage 5V DC
Output current 1A
Output power 5W
Efficiency 73,62%
No-load Consumption <0.1W

Legal notice

Support
www.laxihub.com
Symbols

Direct current (DC)

Don’t throw batteries or out-of-order products with household waste (garbage). The dangerous substances that they are likely to include may harm health or the environment. Make your retailer take back these products or use the selective collection of garbage proposed by your city.

Hereby, Laxihub, declares that the radio equipment type ‘PTCam’ is in compliance with the Directive 2014/53/EU The full test of the EU declaration of conformity is available at the following Internet address: www.laxihub.com

Functions

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution!  Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Arenti User Manuals

Related Manuals