EBECO 200 Cable Kit Cableflex 11 Instruction Manual
- June 12, 2024
- EBECO
Table of Contents
Cable Kit 200/500
Cableflex 11
INSTALLATION INSTRUCTIONS
Skapa garantibevis direkt i mobilen
garantera.ebeco.se
Information requirements for electric local space heaters according to eco design, regulation (EU 2015/1188)
200 Cable Kit Cableflex 11
Symbol | Value | Unit |
---|---|---|
Heat output | ||
Nominal heat output | Pnom | See manual |
Min. heat output
(indicative)| Pmin| 0 kW
Max. continous heat output| Pmax, c| See manual
Auxiliary electricity
consumption| Cable Kit 200
(EB-Therm 205)|
At nominell heat output| elmax| See manual
At min. heat output| elmin| 0,000 kW
In stand-by mode| elSB| 0,000 kW
Auxiliary electricity
consumption| Cable Kit 500
(EB-Therm 500)|
At nominell heat output| elmax| See manual
At min. heat output| elmin| 0,000 kW
In stand-by mode| elSB| 0,000 kW
| Cable Kit 200
(EB-Therm 205)| Cable Kit 500
(EB-Therm 500)
Type of heat output/room temp.
control (select one)| |
Single stage heat output and no room
temp. control| NEJ
No| NEJ
No
Two or more manual stages, no room
temp. control| NEJ
No| NEJ
No
With mechanic thermostat
room temp. control| NEJ
No| NEJ
No
reglering
With electronic room temp. control| NEJ
No| NEJ
No
reglering plus dygnstimer With electronic room temp. control
plus day timer| NEJ
No| NEJ
No
reglering plus veckotimer
With electronic room temp. control
plus week timer| JA
Yes| JA
Yes
Other control options
(multiple selections possible)| |
Room temp. control with presence detection| NEJ
No| NEJ
No
Room temp. control with open
window detection| JA
Yes| JA
Yes
With distance control detection| NEJ
No| JA
Yes
With adaptive start control| JA
Yes| JA
Yes
With working time limitation
(operating time limitaion)| NEJ
No| JA
Yes
With black bulb sensor| NEJ
No| NEJ
No
Ecodesign
Information requirements for electric room heaters
In accordance with the ecodesign requirements for room heaters according to
Regulation EU 2015/1188
| Designation| Value Unit
---|---|---
Heat output| |
Nominal specified heat output| Pnom| See manual
Lowest heat output (indicative)| Pmin| 0 kW
Maximum continuous heat output| Pmax, c| See manual
Additive consumption| Cable Kit 200
(EB-Therm 205)|
At nominal specified heat output| elmax| See manual
At lowest heat output| elmin| 0.000 kW
In standby mode| elSB| 0.000 kW
Additive consumption| Cable Kit 500
(EB-Therm 500)|
At nominal specified heat output| elmax| See manual
At lowest heat output| elmin| 0.000 kW
In standby mode| elSB| 0.000 kW
| Cable Kit 200
(EB-Therm 205)| Cable Kit 500
(EB-Therm 500)
Type of heat output/room temperature control (select one)| |
One-step heat output without room temperature control| NO| NO
Two or more manual steps without room temperature control| NO| NO
With mechanical thermostat for room temperature control| NO| NO
With electronic room temperature control| NO| NO
With electronic room temperature control plus 24-hour timer| NO| NO
With electronic room temperature control plus weekly timer| YES| YES
Other control methods (several options can be selected)| |
Room temperature control with presence detection| NO| NO
Room temperature control with detection of open windows| YES| YES
With the possibility of remote control| NO| YES
With adjustable start control| YES| YES
With operating time limitation| NO| YES
With black body sensor| NO| NO
Welcome!
Thank you for choosing Ebeco. We hope you will be happy with your underfloor
heating system for many years to come.
For the guarantee to apply, the product must be installed and used as
described in this manual. It is therefore important that you read the manual.
If you have any questions, please contact us at Ebeco.
Call 031-707 75 50 or send an email to info@ebeco.se.
You’ll find more information at ebeco.se.
Important
The underfloor heating system is a high voltage system and must thus be installed according to applicable regulations by an authorised electrician. For the guarantee to apply, the guarantee certificate must be correctly and completely fillein, and signed by an authorised electrician. May only be installed indoors.
-
The heating cable must not be cut. Furthermore, it may neither be crossed nor installed with spacing of less than 5 cm.
-
The connection cable may be cut.
-
The thermostat’s sensor cable may be cut.
-
The cable must be measured for resistance and insulation as per the instructions. Document the values in our web app, Garantera Ebeco, or in the guarantee certificate.
-
Either a diagram or photo of the cable routing must be documented.
-
The sign Heating Cable Installed must be posted at the main junction box.
-
Heating must be regulated with Ebeco’s EB-Therm thermostats.
-
The system must be connected to 230 V via a 30-mA earth fault circuit breaker.
-
The heating cable must not be run under stationary furnishings, such as kitchen counters, closets, inner walls, etc. because this produces elevated temperatures.
-
In wet rooms, the heating cable must be run under a sealing layer.
-
Wait 4 weeks after applying screed before turning on the heat.
This gives the screed time to dry properly. -
In rooms with wooden floors the Room and floor thermostat function must always be used.
-
When laying on reinforcement mesh, the cable must be laid on the top of the reinforcement mesh.
-
The maximum permissible heat resistance of the floor material is 0.16 m² K/W.
Subflooring
The heating cable is laid on floor constructions of concrete, plaster or
chipboard and must then be screeded with a suitable levelling compound.
When applying screed on EPS concrete/cement, a reinforcement mesh is required
in between as a spacer before the heating cable is laid.
On uninsulated concrete floors against the ground, additional insulation is
always recommended. Also, that the heating is not switched off completely
during the summer to counteract moisture rising.
Flooring materials
Cable Kit/Cableflex can be installed under tiles and natural stone floors,
wood and laminate floors and linoleum.
When screeding, the heating cable must be laid in a minimum screed layer with
a suitable levelling compound as follows:
Tile/natural stone floor 5 mm Wood/laminate flooring, 10 mm Linoleum 15 mm
See the applicable industry regulations for exact instructions regarding floor
construction, screeding, sealing layers, tiling, jointing etc. Please contact
your dealer for answers to specific questions.
Recommendations and Max. output depending on criteria and needs:
Heating cable| Recommended output|
---|---|---
For screed| 11 W/m, c/c 7–15 cm|
Floor material| Regulation| Subflooring
Tile/natural stone Max 160 W/m² Max| Room/Floor| Concrete
Max 160 W/m²
Wood/laminate/linoleum Max 75 W/m²| Room +floor| Combustible Max 120 W/m² In
wooden subfloor Max 80 W/m²
The output requirement of the room is governed by how well insulated it is,
its air circulation and outdoor temperature.
Industry guidelines for wood/laminate and linoleum on underfloor heating
General conditions: The maximum permissible surface temperature is 27°C. This
also applies under carpets and furniture.
Coverage:
Note that with all covering of wood/laminate and linoleum floors laid on
underfloor heating, there is a risk:
- Of overtemperature in the floor
- That the temperature in the room becomes too low
Coverings include: carpets, beds without ventilated bases, bookshelves with fully-covering bottom, kitchen cabinets etc.
Specifications
Only on concrete subflooring
Cable Kit
500| Cable Kit
200| Cableflex
11| Output| Length| Nominal
specified
heating output| Max cont.
heat
output| AREA
75 W/m²| AREA
110 W/m²| AREA
140 W/m²| AREA
160 W/m²| Resistance
---|---|---|---|---|---|---|---|---|---|---|---
89 610 80| 89 608 38| 89 601 02| 100 W| 8.9 m| 0.1 kW| 0.1 kW| 1.1 m²| 0.8
m²| 0.6 m²| 0.5 m²| 534 Ω
89 610 81| 89 608 50| 89 601 04| 150 W| 13.5 m| 0.15 kW| 0.15 kW| 2.0 m²| 1.35
m²| 1.1 m²| 0.9 m²| 350 Ω
89 610 82| 89 608 51| 89 601 06| 200 W| 18.5 m| 0.2 kW| 0.2 kW| 2.7 m²| 1.85
m| 1.5 m²| 1.3 m²| 260 Ω
89 610 83| 89 608 52| 89 601 08| 260 W| 23 m| 0.26 kW| 0.26 kW| 3.4 m²| 2.3
m²| 1.8 m²| 1.6 m²| 207 Ω
89 610 84| 89 608 53| 89 601 10| 330 W| 31 m| 0.33 kW| 0.33 kW| 4.4 m²| 3.1
m²| 2.3 m²| 2.1 m²| 161 Ω
89 610 85| 89 608 54| 89 601 12| 400 W| 37 m| 0.4 kW| 0.4 kW| 5.3 m²| 3.7 m²|
2.8 m²| 2.5 m²| 133 Ω
89 610 86| 89 608 55| 89 601 14| 470 W| 43 m| 0.47 kW| 0.47 kW| 6.3 m²| 4.3
m²| 3.4 m²| 3.0 m²| 112 Ω
89 610 87| 89 608 56| 89 601 16| 540 W| 49 m| 0.49 kW| 0.49 kW| 7.2 m²| 4.9
m²| 3.9 m²| 3.4 m²| 98 Ω
89 610 88| 89 608 57| 89 601 18| 650 W| 58 m| 0.65 kW| 0.65 kW| 8.7 m²| 5.8
m²| 4.7 m²| 4.1 m²| 81 Ω
89 610 89| 89 608 58| 89 601 20| 810 W| 73 m| 0.81 kW| 0.81 kW| 10.7 m²| 7.3
m²| 5.8 m²| 5.0 m²| 66 Ω
89 610 90| 89 608 59| 89 601 22| 960 W| 86 m| 0.96 kW| 0.96 kW| 12.8 m²| 8.6
m²| 6.9 m²| 6.0 m²| 55 Ω
89 610 91| 89 608 60| 89 601 24| 1180 W| 107 m| 1.18 kW| 1.18 kW| 16.05 m²|
10.7 m²| 8.4 m²| 7.4 m²| 45 Ω
89 610 92| 89 608 61| 89 601 26| 1380 W| 124 m| 1.38 kW| 1.38 kW| 18.3 m²|
12.4 m²| 9.8 m²| 8.6 m²| 38 Ω
89 610 93| 89 608 62| 89 601 28| 1710 W| 155 m| 1.71 kW| 1.71 kW| 22.7 m²|
15.5 m²| 12.2 m²| 10.7 m²| 31 Ω
89 610 94| 89 608 63| 89 601 30| 2080 W| 187 m| 2.08 kW| 2.08 kW| 27.7 m²|
18.7 m²| 14.9 m²| 13.0 m²| 25 Ω
Supplementary kit without thermostat for Cable Kit 500/200:
89 608 90| | | | | | | | | | |
Tolerance -5 % – +10 %
| | | 1180 W| 107 m| 1.18 kW| 1.18 kW| 16.05 m²| 10.7 m²| 8.4 m²| 7.4 m²| 45 Ω
Materials and accessories
Included in package: | CK 500 | CK 200 | Cableflex 11 |
---|---|---|---|
Underfloor heating cable (2.5 m connection cable) | X | X | X |
Thermostat with sensor cable | X | X | |
Spiral tube with adapter | X | X | |
Adhesive sticks | X | X | |
Reel bracket | X | X | X |
Sign Heating Cable Installed | X | X | X |
Accessories
Cable Clip (89 609 58)
Cable Board (89 601 80)
Tape (89 353 49)
Sensor hose (89 605 41)
Adhesive sticks (16 939 93)
Compare with the contents in your kit. Check the label on the cable reel to
ensure that you have received the correct cable length.
Plan the installation
Because the heating cable may neither be cut nor crossed, installation must be
carefully planned so that the cable is correct for the room. Use the metre
marking on the cable
after half the installation to make any adjustments to c/c distances and to
avoid surplus heating cable once the calculated area has been covered.
Calculate the c/c distance
Do as follows to find the exact c/c distance for cable laying. Calculate the
room’s floor area. Subtract for fixed furnishings, such as cabinets and
counters, so that you obtain the free floor area. Divide the free floor area
by the
cable length to obtain the c/c distance. Depending on the c/c distance, output varies per square metre. In the table, Specifications, you can see the output for various c/cdistances.
Location of sensor and connection cables
1a. Cable Kit includes a spiral tube with sealed ends.
The thermostat’s sensor cable is inserted in the spiral tube.
1b. The sensor cable’s termination may not be covered by carpets or furnishings.
3. The spiral tube and pipe are positioned beside one another in a recess in
the wall.
Make a recess in the floor opposite to where two cable lengths will be
installed. This is where the spiral tube’s termination will be located.
The joint between the heating and connection cables is also positioned in a
recess so as not to protrude through the screed layer. Do not place in the
wall or in the pipe (see image).
2a. The underfloor heating cable has a 2.5-metre connection cable. It is run
in a VP tube/plastic tube designed for electrical materials (not included).
2b. The joint for the connection cable and termination may not be placed in or adjoining any shower spaces/ floor drains. For supplementary kits, both cold cables must be run up and connected in parallel in the thermostat.
Installation
-
The reel bracket simplifies work. Place the reel bracket in the perforated hole under the bottom of the package. Lift the reel onto the reel bracket and place a weight on the package cover. When you pull the cable, the reel will now revolve.
-
Perform the first insulation and resistance measurement of the cable. Fill in the test report or use Garantera on your smartphone.
Prepare the subfloor
-
Ensure that the floor is firmly in place, does not sag and is free from dirt and old floor coverings. Prime the floor surface with Ebeco Primer + (89 605 50) or similar and let it dry.
-
Mark the c/c dimensions of the heating cable. Distance to the wall must be the loop’s c/c dimensions divided by two.
Adhesive, tape or Cable Clip?
The heating cable can be attached with either hot melt adhesive, tape (89 353
- or Cable Clip (89 609 58) for mesh 2.5 mm. Adhesive is used in the
figures. Follow the instructions in general.
Adhesive is preferable for uneven surfaces. Secure the cable with drops of adhesive instead of complete bonding. The lowest application temperature for tape is +18°C, otherwise adhesion is reduced.
In rooms where the underfloor heating cables are to be installed on 2.5 mm mesh, Cable Clip is the ideal accessory. Cable Clip is easily attached to the mesh. The heating cable is then installed directly in the clip.
-
Pull out the first length of heating cable and secure it.
The distance to the wall must be the c/c dimensions of the loop divided by two.
-
This is how the heating cable should be laid around floor drains and similar. Leave space for the floor drain grille. NB! At least 20 cm distance between drain and heating cable!
The cable may not be installed under fixed furnishings, such as toilet bowls. It can be advantageous to secure toilet bowls with silicone instead of screws. -
Fastening of heating cable must be done with c/c 20 cm.
-
Perform other insulation and resistance measurements and fill in the test report or Garantera on your smartphone. Document the location of the cable with a photo.
-
Cover the floor with a suitable floor filler. Keep in mind that the cable must be under the sealing layer in wet rooms.
-
If possible, after applying screed, alternatively after flooring has been laid, perform a third insulation and resistance measurement of the heating cable. Fill in the test report or use Garantera on your smartphone.
For tiles, wait 4 weeks after installation before turning on the heat.
Energy-saving tips!
Ebeco Cable Board is an insulation board especially designed for Cable
Kit/Cableflex under tiled and natural stone floors. It has grooves for laying
the heating cable and consequently provides quick and uniform positioning of
the heating cable without the need of manually measuring centre-to-centre
distances. The insulation board’s properties make the underfloor heating
system extremely responsive to adjustments. Compared to the reference
installation (60s-70s house with an uninsulated floor construction of 15 cm
thick concrete slab on the ground), Cable Board provides an energy saving of
up to 45%. On concrete surfaces, it can be used both in wet rooms and dry
areas. On wooden surfaces, it may only be used in dry areas and then replaces
the plasterboard in the floor construction. In wet rooms with wooden
subfloors, Ebeco Thermo Board is recommended.
Test report (Cable Kit 200/500, Cableflex 11)
| Before laying| After fixation| After floor covering
---|---|---|---
Product| Resistance value| Insulation value| Resistance value| Insulation
value| Resistance value*| Insulation value
E-no| | | | | |
E-no| | | | | |
E-no| | | | | |
E-no| | | | | |
Min. insulation value 10 MΩ at min. 500 V test voltage.
*Tolerance -5 % – +10 %
Products
Product:
Cable Kit 200
Cable Kit 500
Cableflex 11
in combination with:
EB-Therm 55
EB-Therm 205
EB-Therm 500
EB-Therm 800
Other control: …………………………………………………………….
Is installed in the following spaces:
| | Article number:| Length/size:| Output/voltage:
---|---|---|---|---
| Hall| | |
| Kitchen| | |
| Wet room| | |
| Living room| | |
| Bedroom| | |
| Outdoor room| | |
| Other| | |
Tip! Extended 25 year guarantee and documenting made easier with
Garantera
The installation is documented with photos/drawings
Do you want to avoid the bother of filling in and keeping track of these
pages? Garantera is a service that makes things a little easier for authorised
installation technicians. The service allows you to document measurement data,
save installation photos and create a digital guarantee certificate to send to
the customer. Read more about the service and get started at
garantera.eboco.se.
Electrical installation performed by:
Company: ………………………………………………………..
Date: …………………………………………………………
Installer (block capitals): ………………………………………
Signature: ………………………………………………………..
Terms of Guarantee
Cable Kit, Cableflex, Thermoflex Kit, Thermoflex, Foil Kit, Foil 230 V and
Multiflex 20
Ebeco AB provides a 12-year guarantee for material faults to heating
cables/foil including supplied accessories and insulation board in Cable Kit,
Thermoflex Kit, Thermoflex, Foil Kit, Foil 230 V and Multiflex 20-cable,
hereafter referred to as the “Products”.
Should material faults occur to the Products during the period of the
guarantee, Ebeco AB agrees to repair or replace the Products without cost to
the purchaser. Ebeco AB also undertakes to restore the floor to its original
condition after performed repair or replacement. To be able to rectify the
fault, the purchaser must have saved or have access to 1 m² of the original
flooring material.
Ebeco AB provides a 5-year product guarantee for the supplied thermostat.
The guarantee only applies under the condition that installation of the
Products is performed by an authorised electrician in accordance with
applicable regulations and the installation instructions issued by Ebeco. And
that one of the following requirements is met:
A) The installation is performed using and documented in Ebeco’s service,
Garantera.
Or
B) This guarantee certificate including the test report is completed in full,
and along with material specifications or an invoice, signed by the
electrician who performed the installation. Furthermore, there must be photos
that show the Products in their entirety after installation but before
covering, or alternatively, a detailed drawing of the end connections and
joints of the Products as well as the exact locations of floor sensors.
The guarantee does not apply to installations performed by non-authorised
electricians or if a non-authorised electrician has made modifications or
repairs. Furthermore, the guarantee does not apply to faults that have
occurred as a result of use of improper materials and floor constructions, or
as a result of incorrect installation. Damage caused by vandalism, fire,
lightning or water, or damage caused by carelessness, abnormal use or as a
result of accidents, is not covered either.
To make a guarantee claim, the following applies: Ebeco AB must be notified
before any action is taken. Furthermore, a guarantee certificate with an
accompanying invoice for installation or material specification and a
completed and signed test report must be presented.
Extend the guarantee to 25 years with Garantera
Ebeco’s digital service, Garantera, documents all heating cable installations
in a simple, safe and structured way. An installation made using Garantera
automatically gets an extended 25 year guarantee for material defects. The
extended guarantee only applies if the product has been installed together
with an applicable control system and by an authorised electrician.
A digital guarantee certificate is e-mailed from Garantera to the user, who is
then responsible for saving it and being able to present it in the event of a
guarantee claim.
A product guarantee of 5 years applies to the thermostat.
EBECO AB
Martin Larsson, CEO
EBECO AB
Lärjeågatan 11
415 02 Göteborg, SWEDEN
Phone +46 31 707 75 50
ebeco.com
info@ebeco.se
Manual CK/CF 221005
References