TRANE EHUMD200ABM00B Small Bypass Humidifier User Manual
- June 6, 2024
- Trane
Table of Contents
TRANE EHUMD200ABM00B Small Bypass Humidifier
INTRODUCTION
Thank you for your recent purchase of our humidifier. The addition of this
product to your heating and cooling system will increase your level of comfort
by adding just the right amount of moisture to your indoor environment. During
the heating season, your humidifier will not only make you feel more
comfortable, but it will help protect your home and your furnishings as well.
Your new humidifier is easy to use and easy to live with. Simple maintenance
is required on a periodic basis to keep it in peak operating condition. This
Use and Care manual will outline these steps for you, as well as other basic
operating procedures so you can enjoy the full benefits of your new
humidifier.
How Your Humidifier Operates:
During the winter, your comfort relies on two things: the perfect temperature
and the perfect amount of moisture. Your new humidifier will provide your home
with the recommended indoor relative humidity to ensure your comfort all
winter long. Replacement Humidifier Pads are available from your installing
dealer.
WARNING ELECTRICAL SHOCK HAZARD: Disconnect Electrical Power and Shut Off Water Supply Before Servicing. Failure to follow this warning may cause property damage, personal injury or death.
CAUTION PERSONAL INJURY HAZARD: Turn Humidifier Control to “OFF” or lowest setting before servicing. Sudden operation may cause personal injury or property damage.
PRINCIPLE OF OPERATION
Your new humidifier has been installed to operate in conjunction with your
furnace. When the Humidifier Control calls for humidity and the furnace blower
is operating, water flows to the distribution tray located at the top of the
humidifier. The water is evenly distributed across the width of the tray and
over the Humidifier Pad. Dry, hot air is moved through this moisture laden
Humidifier Pad where it is evaporated into a vapor. This humidified air is
circulated throughout your home. Humidified air helps to reduce static
electricity, prevents wood furniture from drying out, helps prevent nasal
passages from becoming too dry and makes your home more comfortable.
Important Notes About Your Humidifier:
When the humidifier is operating, there will be a small, steady stream of
water to drain. Do not use the saddle valve to regulate the water flow. The
saddle valve is designed to be either completely open or completely closed.
Although your humidifier incorporates a self-flushing action, the Humidifier
Pad will develop mineral build-up over time. To assure high capacity,
trouble-free performance the Humidifier Pad should be replaced annually. For
water distribution trays with a synthetic fabric liner: The synthetic fabric
liner provides an even water flow over the Humidifier Pad. It is normal for
some mineral deposits to form in the distribution tray as it dries out between
humidification cycles. These deposits can actually help distribute water in
the tray, but if they form enough to block the openings, they should be
removed as described in the “Periodic Preventative Maintenance” section of
this manual.
For water distribution trays with a granular coating: The coating on the
bottom of the distribution tray provides an even flow of water over the
Humidifier Pad. Do not clean the mineral scale off the bottom of the
distribution tray at the end of the humidification season. The scale
actually provides an excellent track for the water to follow.
OPERATING INSTRUCTIONS
Models EHUMD300ABA00B and EHUMD500APA00C with Automatic Humidifier Control: (for Manual Humidifier Control – see page 5)Your Automatic Humidifier Control is installed in the cold air return. During the first heating season, your Automatic Humidifier Control needs to be set initially to match your home’s condition. Please follow these steps when adjusting your Control (refer to Figure A).
- Turn the dial setting knob to “5,” which is within the normal range. During the next 24-48 hours it may be necessary to adjust the dial for more or less humidity, depending on your personal comfort and home’s requirements. Refer to the “Operation Guide” (Table 1).
- During the coldest portion of the first heating season, minor adjustments may be necessary. This is dependent upon your individual home construction, refer to the “Operation Guide” (Table 1).
Operation Guide
TABLE 1 – Operation Guide
Condition Solution
Condensation on windows| Reduce the setting on the control dial by 1
increment.
Lack of humidity| Increase the setting on the control dial by 1 increment.
Humidifier does not operate| Turn dial to “Test.” Make certain furnace and
blower are operating. If humidifier still doesn’t operate, consult your air
conditioning and heating dealer.
Humidifier won’t shut off| Turn dial to “Off.” If humidifier continues to
operate, consult your air conditioning and heating dealer.
Test mode| System operation is checked by setting the knob to “Test.” Make
certain furnace and blower are operating. Humidifier will operate for one
minute.
The relative humidity in your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons. Make note of the dial setting in the event you temporarily move the knob when performing annual maintenance of the Humidifier. Your Automatic Humidifier, is a high precision system that will accurately maintain the relative humidity in your home. For every 1°F change in outdoor temperature, the Control will automatically adjust the indoor relative humidity (RH) by 1/2%. If you would like to determine the RH in your home, follow these steps:
- Determine the outdoor temperature.
- Activate the furnace blower by setting your thermostat fan switch to the “On” position, or setting your thermostat to a higher temperature.
- Turn the Humidifier Control dial setting to the “Off” position. Then, slowly turn the dial clockwise until you hear the solenoid valve “click on.” Next, slowly turn the dial counter clockwise until you hear the solenoid valve “click off.” At this point, make note of the dial setting.
- Locate your dial setting on Table 2. Follow the dial setting to the right until it intersects with the current outdoor temperature. This is the relative humidity in your home under existing conditions.
- Return the thermostat and the Humidifier Control to their original settings.
Relative Humidity Guide
-10 | 0 | 10 | 20 | 30 | 40 | |
---|---|---|---|---|---|---|
1 | 10 | 10 | 10 | 15 | 20 | 25 |
2 | 10 | 10 | 15 | 20 | 25 | 30 |
3 | 10 | 15 | 20 | 25 | 30 | 35 |
4 | 15 | 20 | 25 | 30 | 35 | 40 |
5 | 20 | 25 | 30 | 35 | 40 | 45 |
6 | 25 | 30 | 35 | 40 | 45 | 45 |
7 | 30 | 35 | 40 | 45 | 45 | 45 |
The Automatic Humidifier will accurately control the humidity in your home to
a maximum of 45% RH and a minimum of 10% RH. The values of outdoor temperature
and dial settings may fall in between or outside of the listed values in Table
2. In these cases, you can only approximate your home’s actual indoor RH. To
check the humidifier’s operation, note the Control setting and set the
Automatic Humidifier Control to the test mode when the furnace blower motor is
operating. Water will flow into the humidifier for 1 minute and then it will
turn off. This insures the humidifier is operating properly. Do not leave the
Control in the test mode as it will not operate. Reset the Control to it’s
original setting.
Model EHUMD200ABM00B with Manual Humidifier Control or Model EHUMD300ABA00B
and EHUMD500APA00C with Automatic Humidifier Control in Manual Mode:
(for Automatic Humidifier Control – see page 3)
The Manual Humidifier Control is installed either in the living area
(typically near the thermostat) or in the cold air return. The Automatic
Humidifier Control (in the Manual Mode) is installed in the cold air return.
It is important to anticipate a drop in outdoor temperature and reduce the
setting accordingly to avoid excessive condensation. For example, with an
outdoor temperature of 20°F the recommended setting will be 35% relative
humidity. If the temperature is expected to fall to 0°F that evening, then
merely reduce the setting to 25% several hours prior to the temperature
change.
The recommended settings on the Humidifier Control are based on years of
research (see Table 3) and experience as to what is best for the average home.
These settings represent a compromise between RH levels that would be most
desirable for comfort reasons and humidity levels that are suitable for
protection of your home. For example, a wintertime indoor RH of 50% may be
considered ideal by some, but unfortunately, it probably would result in
damage to your home. Observance of the recommended RH levels on your
Humidifier Control, therefore, is an important safeguard. Condensation of
water on inside windows in the form of fogging or frost is usually an
indication of too high relative humidities. This same condensation can take
place in other areas in your home with the possibility of damage resulting.
TABLE 3 – Outdoor-Indoor Relative Humidity
Outside Temperature Recommended RH
+40°F| 45%
+30°F| 40%
+20°F| 35%
+10°F| 30%
0°F| 25%
– 10°F| 20%
– 20°F| 15%
The Humidifier Control is a precision instrument that can be used to determine
the RH accurately in your home during the winter. Turn the dial to the lower
setting, then reverse the dial direction slowly until a “click” is heard. At
this point, read the RH on the dial. This will be very close to the actual RH
in your home. To check the humidifier operation, set the Humidifier Control
above the click point, make sure that the water saddle valve is open and that
there is electricity to the humidifier. Generally, the furnace and blower
motor must be operating for the Humidifier Control to function. After the
humidifier has operated for several minutes and water is entering the
humidifier and coming out at the drain, reduce the Humidifier Control setting
below the click point and the humidifier should automatically shut off. Now
set the Humidifier Control dial at the recommended inside relative humidity,
depending on the outside temperature. Follow the suggested settings prior to a
drop in the outside temperature.
Additional Information
Be sure to keep fireplace dampers closed when not in use. They provide an
excellent escape route for heat, as well as humidity. Humidity is lost at an
even faster rate than heat because water vapor tends to seek its own level and
your humidifier would not be able to replace it even when running at full
capacity. On occasion, indoor moisture producing activities such as clothes
drying, cooking, showers, etc., may raise the relative humidity level higher
than it should be, even though the Humidifier is not operating. Telltale
indications, again, are condensation or frost on cold surfaces such as
windows, doors, walls, etc. If such condensation persists for several hours,
your home should be ventilated to dissipate the potentially damaging excess
moisture.
EFFECT OF WATER CHARACTERISTICS
Your humidifier will operate effectively using either hot, cold, hard or mechanically softened water. Whether to use available tap water, even though it may be quite hard, or chemically softened water, is a common concern to homeowners when installing a humidifier. Because of the humidifier’s design, most of these solids are effectively controlled by flushing them down the drain. Water used in homes contains varying amounts of minerals. The residue remaining as a result of hard water evaporation is primarily calcium and magnesium components and is usually quite hard, scaly, and dense. Residue from softened water tends to be soft and fluffy and has a greater volume than hard water residue. The service life of a Humidifier Pad may be extended by using hard water, but in either case, the Humidifier Pad should be changed once a year. This is why proper maintenance is important and necessary. Service hot water 140°F maximum, is recommended with flow through, drain type units for increasing capacity.
ANNUAL MAINTENANCE
For best performance, we recommend that you replace the Humidifier Pad
in your Humidifier annually.
To obtain a replacement:
- Call your heating and air conditioning dealer.
- Look in the Yellow Pages under Heating & Air Conditioning Contractors.
- if none of the above are successful and you still need information, please feel free to write us or send an email to our website.
ANNUAL SUMMER SHUTDOWN
For Models EHUMD200ABM00B, EHUMD300ABA00B close the bypass damper.
AUTOMATIC HUMIDIFIER CONTROL: Humidifiers controlled by the Automatic
Humidifier Control require no control adjustment. Shut off the water supply to
the humidifier by closing the saddle valve.
MANUAL HUMIDIFIER CONTROL: For humidifiers controlled by a Manual
Humidifier Control, simply turn the Control to the “Off” position. Shut off
the water supply to the humidifier by closing the saddle valve.
PERIODIC PREVENTATIVE MAINTENANCE
WARNING: Disconnect Electrical Power and Shut Off Water Supply Before Servicing. Failure to follow this warning may cause property damage, personal injury or death.
CAUTION: Turn Humidifier Control to “OFF” or lowest setting before servicing. Sudden operation may cause personal injury or property damage.
NOTE: Periodic inspection and preventive maintenance of your total heating system is important for efficient and safe operation. Your heating dealer should perform humidifier service at the same time. All models are equipped with an in-line water strainer and orifice as shown below. These parts should be inspected and cleaned periodically to assure continued proper humidifier performance.
WATER LINE INSPECTION AND SERVICE INSTRUCTIONS
- Disconnect electrical power to the furnace and shut off water supply.
- Disconnect the water line at the inlet compression nut.
- Remove the in-line strainer from inside the inlet side of the valve by using a small nail or wire.
- Flush the in-line strainer clean or replace with a new strainer, Service Part No. SRA00859.
- Reconnect the inlet water line. Double Wrench to Prevent Leaking.
- Disconnect the water feed tube at the outlet compression nut.
- Inspect the water feed tube (plastic only) by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle, or has been damaged.
- Remove the orifice from the copper or plastic water feed tube and make sure this small opening is unplugged.
- Replace the orifice and reconnect the water feed tube. Double Wrench to Prevent Leaking.
- Remove the drain line from the bottom of the humidifier. If applicable, flex it to loosen any mineral deposits or blockages. Flush the drain line with water under pressure to clear it of any debris, and slip it back onto the drain fitting. If drain line does not clean properly, replace it. Inspect the drain line to make sure it has a constant downward slope and is not flattened or blocked.
- Turn on water supply and reconnect electrical power to the furnace.
CAUTION: Turn Humidifier Control to “OFF” or lowest setting before servicing. Sudden operation may cause personal injury or property damage.
-
Front Cover
-
Feed Tube
-
Integral Bypass Damper
-
Evaporative Assembly
-
Distribution Tray
-
“V” Notches
-
Humidifier Pad
-
Scale Control Insert
-
Drain Line
-
Note Humidifier Control setting and turn dial to the “OFF” position.
-
Turn off water supply. Turn the integral bypass damper (3) to the SUMMER position.
-
Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both hands. Set aside.
-
Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the evaporative assembly (4). Pull this assembly out by grasping at top and tipping out.
-
Unsnap the distribution tray (5) from the scale control insert (8). Lightly scrape out or brush off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits.
-
Slide the Humidifier Pad (7) out from the scale control insert (8). Clean the scale control insert of mineral deposits. Replace the Humidifier Pad annually with a BAYPAD01A1010A Humidifier Pad for Model EHUMD200ABM00B and BAYPAD02A1310A Humidifier Pad for Model EHUMD300ABA00B. Slide the Humidifier Pad back into the scale control insert with the colored spot up and snap the distribution tray (5) back into place.
-
Inspect the plastic feed tube (2) by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle, or has been damaged.
-
Reinstall the evaporative assembly (4) into the humidifier by fitting its drain into the round receptacle at the base of the humidifier. Push the assembly in at the top until it snaps into place. Push the
-
Remove the drain line (9) from the bottom of the humidifier. If applicable, flex it to loosen any mineral deposits or blockage. Then flush it with water under pressure. If it does not properly clear, replace it. Slip drain line back onto the drain fitting. Make sure the drain line has a constant downward slope and is not flattened or blocked.
-
Turn on the water supply. Return integral bypass damper (3) to appropriate position.
-
Check system operation: Manual Humidifier Control (EHUMD200ABM00B): With the furnace blower operating and the furnace calling for heat, turn up Control and check system operation.
Automatic Humidifier Control (EHUMD300ABA00B): (Automatic or Manual mode) Check system operation and reset Change Humidifier Pad indicator by setting the knob to “Test/Reset”. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. -
Set Humidifier Control to its original position.
WARNING: Disconnect Electrical Power and Shut Off Water Supply Before Servicing. Failure to follow this warning may cause property damage, personal injury or death.
CAUTION: Turn Humidifier Control to “OFF” or lowest setting before servicing. Sudden operation may cause personal injury or property damage.
-
Humidifier Cover Assembly
-
Base Assembly
-
Evaporative Assembly
-
Distribution Tray
-
”V” Notches
-
Humidifier Pad
-
Scale Control Insert
-
Drain Line
-
Power Cord
-
Note Humidifier Control setting and turn dial to the “OFF” position.
-
Disconnect electrical power and turn off water supply.
-
Unlatch humidifier front cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside.
-
Pull out the evaporative assembly (3) by grasping at the top and tipping out.
-
Unsnap the distribution tray (4) from the scale control insert (7). Follow the instructions below depending upon the type of distribution tray in your humidifier: For trays with a synthetic fabric liner: Lightly scrape out or brush off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits. For trays with granular coating: Do not scrape off the granular coating, but lightly scrape out any mineral deposits and clean the “V” notches (5). This textured surface helps ensure even water flow for maximum performance. If the granular coating has been removed, replace distribution tray.
-
Slide the Humidifier Pad (6) out from the scale control insert (7). Clean the scale control insert of mineral deposits. Replace Humidifier Pad annually with a BAYPAD02A1310A Humidifier Pad. Slide the Humidifier Pad back into the scale control insert with the colored spot up and snap the distribution tray (4) back into place.
-
Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle, or has been damaged.
-
Reinstall the evaporative assembly (3) into the humidifier by fitting its drain into the round receptacle at the base of the humidifier. Push the assembly in at the top between the retaining ribs that hold the assembly in place in a vertical position.
-
Remove the drain line (8) from the bottom of the humidifier. If applicable, flex it to loosen any mineral deposits or blockage. Then flush it with water under pressure. If it does not clear, replace it. Slip drain line back onto the drain fitting. Make sure the drain line has a constant downward slope and is not flattened or blocked.
-
Reinstall front cover assembly (1) by hooking at the top of the base assembly (2) and latching at the bottom.
-
Reconnect electrical power (9) and turn on the water supply.
-
Check system operation: Automatic Humidifier Control: (Automatic or Manual mode) Check system operation and reset Change Humidifier Pad indicator by setting the knob to “Test/Reset”. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.
-
Set Humidifier Control to its original position.
NOTE: The motor is permanently lubricated and does not need to be oiled.