RED LABEL RL750WALL Wall Mount Fan Owner’s Manual

June 6, 2024
RED LABEL

RED-LABEL-logo

RED LABEL RL750WALL Wall Mount Fan

RED-LABEL-RL750WALL-Wall-Mount-Fan-image

Blade

Diameter

| Motor

Input Output

| Max. Air

Delivery

| Oscillating

Range

| No of

Speeds

| Fan Head

Tilt

---|---|---|---|---|---
750mm| 240V 50Hz 280W| Up to 300m³/min| 0º to 90º| 3| 15°

WARNING

IMPORTANT: READ ALL INSTRUCTIONS BEFORE USE

WARNING
The instructions and warnings contained in this manual should be read and understood before using or operating this equipment. Do not allow anyone to use or operate this equipment until they have read this manual and have developed a thorough understanding of how this equipment works. Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders, or cause damage to the equipment and property. Keep this manual in a convenient and safe place for future reference.
Whilst every effort has been made to ensure accuracy of information contained in this manual, the TQB Brands Pty Ltd policy of continuous improvement determines the right to make modifications without prior warning.

SAFETY INSTRUCTIONS

SAFETY OPERATING INSTRUCTIONS

  • This product is intended for indoor use only.
  • Always operate the product from a power source of the same voltage, frequency and rating as indicated on the product identification plate.
  • To reduce the risk of electric shock, do not use this fan with any solid-state speed control device.
  • Ensure the Wall Mount Fan is disconnected from power before servicing.
  • Use the right product for the job. There are certain applications for which the Wall Mount Fan was designed.
  • Do not modify the Wall Mount Fan and do not use the Wall Mount Fan for a purpose for which it was not intended.

CAUTION WITH WALL FITMENT INSTRUCTIONS

Installation of the wall bracket support arm:
The bent support arm can be installed upward or downward. In both cases, the longest locking bolt must penetrate the small hole at the end of the bent part in order to avoid falling off the wall.
Assembly and installation:
For convenient transportation, the supporting arm of the wall mount fan is disassembled in packing. Please ensure you assemble and install the fan according to the drawings of this manual.

WALL MOUNT INSTRUCTIONSRED-LABEL-RL750WALL-Wall-Mount-Fan-
fig1

ASSEMBLY, OPERATION, PREVENTITIVE MAINTENANCE

FEATURES
This Red Label Workshop Fan is a great value for money pedestal fan which is ideal for cooling large open workshop areas

BEFORE USE
Prior to each use conduct a visual inspection by checking for abnormal conditions, such as cracked joins and damaged, loose, or missing parts.
Ensure that the fan is switched off from the supply mains before removing the guards. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.

ASSEMBLY
Assemble the Wall Plate (17) to the Support Arm (18):

  1. Secure the Support Arm [18) to the Wall Plate [17) using the bolts (19,20,21,22) and firmly tighten.

Attach the Fan Motor to the Support Arm

  1. Locate the fixing hole on the motor locating tube & align the hole with the hole in the Support Arm [18) & push in place.
  2. To secure the fan motor to the wall bracket Support Arm, use the long bolt and washer and push through the lower hole & tighten, using the short bolt push through the upper hole and tighten.

Attach the rear Safety Grill to the Fan Motor

  1. Align the rear safety grill (8) to the fan motor housing so that the fan grill securing hole is at the bottom of the fan and align the four screw holes.
  2. Firmly tighten all the four screws.
  3. Ensure the cable clip (14) is secured so that the cable does not become trapped during oscillation

Attach the Fan Blade to the Fan Motor

  1. Rotate the fan motor shaft until the rebated flat area on the shaft is in the 12 o’clock position.
  2. Locate the lock screw in the fan blade coupling; whilst aligning the screw and motor shaft rebated flat area push the Fan Blade (3) all the way onto the shaft and firmly tighten the grub screw by rotating in a clockwise direction.

Attach the front Safety Grill to the Fan Motor

  1. Align the top locking clip on the Front Grill (2) to the top centre of the Rear Grill (8) that has already been secured to the fan motor. Lock the side and bottom clips in place.
  2. Secure the front & rear safety grills together using the fan grill securing hole in the bottom of the fan grill by inserting the fixing screw and nut provided.
  3. Push the centre plate onto the front of the Grill with the TQ logo level or horizontal.

OPERATION

Oscillating Control:
The oscillation pattern can be adjusted from 0-90 degrees. When the adjusting screw is moved towards the rotating axle, the fan will oscillate less of an angle. The longer-the distance from adjusting screw, the larger the oscillating angle will be. Before you change the oscillating angle, disconnect the 240V power supply, then loosen the adjusting screw and adjust to obtain a satisfactory angle.
Change of the wind direction:
If you want to change the direction of the air circulation, disconnect the power supply and loosen the direction adjustment bolt to adjust the direction of the fan head to required position and re-tighten the bolt. It is not necessary to move the base of the fan.
Head angle adjustment:
Disconnect the power, hold the head of fan, loosen the adjustment bolt and stopping bolt, adjust the fan to satisfactory position and tighten up the two bolts. When adjusting the angle of the fan, ensure to keep it within the groove of the lower connection. If you do not follow these instructions, the oscillating function may wear and stop working. Adjustment of air volume
Turn the switch on the back of the fan head to control the operation of the fan to adjust air volume, “1-3” speeds indicate different air volume.

STORAGE

This Wall Fan should always be stored in a dry location on a level surface.
When you stop using the fan, you should clean the fan, pack it and put it in dry places, be careful not to damage the fan.

MAINTENANCE

Disconnect power prior to any maintenance
Inspect the general condition of the TradeQuip Industrial Wall Fan checking:

  • for loose hardware
  • cracked, bent, or broken parts, and
  • any other condition that may affect the Wall Fan’s safe operation
SERVICE & REPAIR

Any Red Label Fan found damaged in any way, or found to be worn or operates abnormally should be removed from service until repaired by an authorised service agent. Owners and/or operators should be aware that repair of this product may require specialised equipment and knowledge. Only authorised parts, labels and decals shall be used on this equipment. Annual inspection of the Wall Fan is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the manufacturer.

PARTS LIST WALL FAN

RED-LABEL-RL750WALL-Wall-Mount-Fan-
fig2

Part #| Description| QTY|  | Part #| Description| QTY
---|---|---|---|---|---|---
1| Centre Plate| 1| 12| Washer| 1
2| Front Grill| 1| 13| Lower Connection| 1
3| Fan Blade| 1| 14| Wiring Clip| 1
4| Screw| 1| 15| Bolt| 1
5| Bolt| 4| 16| Screw| 1
6| Spring Washer| 4| 17| Support Arm| 1
7| Washer| 4| 18| Wall Plate| 1
8| Rear Grill| 1| 19| Bolt| 1
9| Motor| 1| 20| Bolt| 1
10| Nut| 1| 21| Nut| 1
11| Spring Washer| 1| 22| Bolt| 1

WARRANTY

Red Label products have been carefully tested and inspected before shipment and are guaranteed to be free from defective materials and workmanship for a period of 12 months from the date of purchase except where tools are used for commercial purposes when the guarantee period is ninety days from the date of purchase.
Should this piece of equipment develop any fault, please return the complete tool to your nearest authorised warranty repair agent or contact TQB Brands Pty Ltd Warranty team – [email protected].
If upon inspection it is found that the fault occurring is due to defective materials or workmanship, repairs will be carried out free of charge. This guarantee does not apply to normal wear and tear, nor does it cover any damage caused by misuse, careless or unsafe handling, alterations, accident, or repairs attempted or made by any personnel other than the authorised TQB Brands Pty Ltd repair agent.
This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised.
Your TQB Brands Pty Ltd guarantee is not effective unless you can produce upon request a dated receipt or invoice to verify your proof of purchase within the 12month period.

Consumer Guarantee

Our goods come with a guarantee that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Made in China to TQB Brands Pty Ltd specifications
Visit us at www.tqbbrands.com.au