RED LABEL RL750WALL Wall Mount Fan Owner’s Manual
- June 6, 2024
- RED LABEL
Table of Contents
RED LABEL RL750WALL Wall Mount Fan
Blade
Diameter
| Motor
Input Output
| Max. Air
Delivery
| Oscillating
Range
| No of
Speeds
| Fan Head
Tilt
---|---|---|---|---|---
750mm| 240V 50Hz 280W| Up to 300m³/min| 0º to 90º| 3| 15°
WARNING
IMPORTANT: READ ALL INSTRUCTIONS BEFORE USE
WARNING
The instructions and warnings contained in this manual should be read and
understood before using or operating this equipment. Do not allow anyone to
use or operate this equipment until they have read this manual and have
developed a thorough understanding of how this equipment works. Failure to
observe any of the instructions contained in the manual could result in severe
personal injury to the user or bystanders, or cause damage to the equipment
and property. Keep this manual in a convenient and safe place for future
reference.
Whilst every effort has been made to ensure accuracy of information contained
in this manual, the TQB Brands Pty Ltd policy of continuous improvement
determines the right to make modifications without prior warning.
SAFETY INSTRUCTIONS
SAFETY OPERATING INSTRUCTIONS
- This product is intended for indoor use only.
- Always operate the product from a power source of the same voltage, frequency and rating as indicated on the product identification plate.
- To reduce the risk of electric shock, do not use this fan with any solid-state speed control device.
- Ensure the Wall Mount Fan is disconnected from power before servicing.
- Use the right product for the job. There are certain applications for which the Wall Mount Fan was designed.
- Do not modify the Wall Mount Fan and do not use the Wall Mount Fan for a purpose for which it was not intended.
CAUTION WITH WALL FITMENT INSTRUCTIONS
Installation of the wall bracket support arm:
The bent support arm can be installed upward or downward. In both cases, the
longest locking bolt must penetrate the small hole at the end of the bent part
in order to avoid falling off the wall.
Assembly and installation:
For convenient transportation, the supporting arm of the wall mount fan is
disassembled in packing. Please ensure you assemble and install the fan
according to the drawings of this manual.
WALL MOUNT INSTRUCTIONS
ASSEMBLY, OPERATION, PREVENTITIVE MAINTENANCE
FEATURES
This Red Label Workshop Fan is a great value for money pedestal fan which is
ideal for cooling large open workshop areas
BEFORE USE
Prior to each use conduct a visual inspection by checking for abnormal
conditions, such as cracked joins and damaged, loose, or missing parts.
Ensure that the fan is switched off from the supply mains before removing the
guards. If the supply cord is damaged, it must be replaced by the
manufacturer, service agent or similarly qualified persons in order to avoid a
hazard.
ASSEMBLY
Assemble the Wall Plate (17) to the Support Arm (18):
- Secure the Support Arm [18) to the Wall Plate [17) using the bolts (19,20,21,22) and firmly tighten.
Attach the Fan Motor to the Support Arm
- Locate the fixing hole on the motor locating tube & align the hole with the hole in the Support Arm [18) & push in place.
- To secure the fan motor to the wall bracket Support Arm, use the long bolt and washer and push through the lower hole & tighten, using the short bolt push through the upper hole and tighten.
Attach the rear Safety Grill to the Fan Motor
- Align the rear safety grill (8) to the fan motor housing so that the fan grill securing hole is at the bottom of the fan and align the four screw holes.
- Firmly tighten all the four screws.
- Ensure the cable clip (14) is secured so that the cable does not become trapped during oscillation
Attach the Fan Blade to the Fan Motor
- Rotate the fan motor shaft until the rebated flat area on the shaft is in the 12 o’clock position.
- Locate the lock screw in the fan blade coupling; whilst aligning the screw and motor shaft rebated flat area push the Fan Blade (3) all the way onto the shaft and firmly tighten the grub screw by rotating in a clockwise direction.
Attach the front Safety Grill to the Fan Motor
- Align the top locking clip on the Front Grill (2) to the top centre of the Rear Grill (8) that has already been secured to the fan motor. Lock the side and bottom clips in place.
- Secure the front & rear safety grills together using the fan grill securing hole in the bottom of the fan grill by inserting the fixing screw and nut provided.
- Push the centre plate onto the front of the Grill with the TQ logo level or horizontal.
OPERATION
Oscillating Control:
The oscillation pattern can be adjusted from 0-90 degrees. When the adjusting
screw is moved towards the rotating axle, the fan will oscillate less of an
angle. The longer-the distance from adjusting screw, the larger the
oscillating angle will be. Before you change the oscillating angle, disconnect
the 240V power supply, then loosen the adjusting screw and adjust to obtain a
satisfactory angle.
Change of the wind direction:
If you want to change the direction of the air circulation, disconnect the
power supply and loosen the direction adjustment bolt to adjust the direction
of the fan head to required position and re-tighten the bolt. It is not
necessary to move the base of the fan.
Head angle adjustment:
Disconnect the power, hold the head of fan, loosen the adjustment bolt and
stopping bolt, adjust the fan to satisfactory position and tighten up the two
bolts. When adjusting the angle of the fan, ensure to keep it within the
groove of the lower connection. If you do not follow these instructions, the
oscillating function may wear and stop working. Adjustment of air volume
Turn the switch on the back of the fan head to control the operation of the
fan to adjust air volume, “1-3” speeds indicate different air volume.
STORAGE
This Wall Fan should always be stored in a dry location on a level surface.
When you stop using the fan, you should clean the fan, pack it and put it in
dry places, be careful not to damage the fan.
MAINTENANCE
Disconnect power prior to any maintenance
Inspect the general condition of the TradeQuip Industrial Wall Fan checking:
- for loose hardware
- cracked, bent, or broken parts, and
- any other condition that may affect the Wall Fan’s safe operation
SERVICE & REPAIR
Any Red Label Fan found damaged in any way, or found to be worn or operates abnormally should be removed from service until repaired by an authorised service agent. Owners and/or operators should be aware that repair of this product may require specialised equipment and knowledge. Only authorised parts, labels and decals shall be used on this equipment. Annual inspection of the Wall Fan is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the manufacturer.
PARTS LIST WALL FAN
Part #| Description| QTY| | Part #| Description|
QTY
---|---|---|---|---|---|---
1| Centre Plate| 1| 12| Washer| 1
2| Front Grill| 1| 13| Lower Connection| 1
3| Fan Blade| 1| 14| Wiring Clip| 1
4| Screw| 1| 15| Bolt| 1
5| Bolt| 4| 16| Screw| 1
6| Spring Washer| 4| 17| Support Arm| 1
7| Washer| 4| 18| Wall Plate| 1
8| Rear Grill| 1| 19| Bolt| 1
9| Motor| 1| 20| Bolt| 1
10| Nut| 1| 21| Nut| 1
11| Spring Washer| 1| 22| Bolt| 1
WARRANTY
Red Label products have been carefully tested and inspected before shipment
and are guaranteed to be free from defective materials and workmanship for a
period of 12 months from the date of purchase except where tools are used for
commercial purposes when the guarantee period is ninety days from the date of
purchase.
Should this piece of equipment develop any fault, please return the complete
tool to your nearest authorised warranty repair agent or contact TQB Brands
Pty Ltd Warranty team –
warranty@tqbbrands.com.au.
If upon inspection it is found that the fault occurring is due to defective
materials or workmanship, repairs will be carried out free of charge. This
guarantee does not apply to normal wear and tear, nor does it cover any damage
caused by misuse, careless or unsafe handling, alterations, accident, or
repairs attempted or made by any personnel other than the authorised TQB
Brands Pty Ltd repair agent.
This guarantee applies in lieu of any other guarantee expressed or implied and
variations of its terms are not authorised.
Your TQB Brands Pty Ltd guarantee is not effective unless you can produce upon
request a dated receipt or invoice to verify your proof of purchase within the
12month period.
Consumer Guarantee
Our goods come with a guarantee that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Made in China to TQB Brands Pty Ltd specifications
Visit us at www.tqbbrands.com.au