Blade Diameter| Motor nput Output| Oscillating Range| Adjustable Height
(Fan Centre)| Fan Head Tilt
---|---|---|---|---
750mm| 240V 50Hz 280W| 0º to 90º| 1235 – 1760mm| 15°

Product Code: RL750FAN

WARNING

IMPORTANT: READ ALL INSTRUCTIONS BEFORE USE

WARNING
The instructions and warnings contained in this manual should be read and understood before using or operating this equipment. Do not allow anyone to use or operate this equipment until they have read this manual and have developed a thorough understanding of how this equipment works. Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders, or cause damage to the equipment and property. Keep this manual in a convenient and safe place for future reference.

Whilst every effort has been made to ensure accuracy of information contained in this manual, the TQB Brands Pty Ltd policy of continuous improvement determines the right to make modifications without prior warning.

INTENDED USE
This product is an Industrial Product and not suitable for household use.

SAFETY INSTRUCTIONS

SAFETY OPERATING INSTRUCTION S

  •  This product is intended for indoor use only.
  • Always operate the product from a power source of the same voltage, frequency, and rating as indicated on the product identification plate.
  • To reduce the risk of electric shock, do not use this fan with any solid-state speed control device.
  • This electrical appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Do not insert fingers or any other foreign object through the front and rear grills into the blade. – Do not operate any product with a damaged cord or plug, after the product malfunctions, is dropped or appears damaged in any way. Return the complete product to the place of purchase for inspection, repair, or replacement.
  • To reduce the risk of electric shock, do not immerse or expose the product or flexible cord to rain, moisture, or any liquid.
  • This product should not be used in the immediate vicinity of water, such as sinks, bathtubs, washbowls, swimming pool, etc. where the likelihood of immersion or splashing could occur.
  • Switch off and unplug from outlet when not in use, before assembling or disassembling parts, and before cleaning. Fully assemble the fan before switching on.
  • Avoid contact with moving parts. Do not insert any object through the grill when the fan is operating.
  •  Do not cover the grill, or operate in close proximity to curtains, etc. – Always disconnect the fan when moving it from one location to another.

ASSEMBLY, OPERATION, PREVENTITIVE MAINTENANCE

  1. FEATURES
    This Red Label Workshop Fan is a great value for money pedestal fan which is ideal for cooling large open workshop areas

  2. BEFORE USE
    Prior to each use conduct a visual inspection by checking for abnormal conditions, such as cracked joins and damaged, loose, or missing parts. Ensure that the fan is disconnected from the mains supply before removing the guards. If the electrical cord is ever found to be damaged, it must be replaced by the

  3.   ASSEMBLY
    Assemble the Pedestal Base to the Telescopic Support Column:
    a) Whilst holding the base [23) on its side, push the Telescopic Support Column [21) into the Pedestal Base [23).
    b) Secure the Telescopic Support Column [21) to the base [9); using the bolt (27) and washers (24,25,26) and firmly tighten.
    Attach the Fan Motor to the Telescopic Support Column
    a) Locate the fixing hole on the motor locating tube & align the hole with the hole in the telescopic stand [17) & push in place.
    b) To secure the fan motor to the telescopic stand [17). use the long bolt and washer and push through the lower hole & tighten, using the short bolt push through the upper hole and tighten.
    c) Ensure the cable clip (14) is secured so that the cable does not become trapped during oscillation
    Attach the rear Safety Grill to the Fan Motor
    a) Align the rear safety grill (2) to the fan motor housing so that the fan grill securing hole is at the bottom of the fan and align the four screw holes.
    b) Firmly tighten all the four screws.
    Attach the Fan Blade to the Fan Motor
    a) Rotate the fan motor shaft until the rebated flat area on the shaft is in the 12 o’clock position.
    b) Locate the lock screw in the fan blade coupling; while aligning the screw and motor shaft rebated flat area push the Fan Blade (3) all the way onto the shaft and firmly tighten the grub screw by rotating in a clockwise direction.
    Attach the front Safety Grill to the Fan Motor
    a) Align the top locking clip on the Front Grill (2) to the top centre of the Rear Grill (8) that has already been secured to the fan motor. Lock the side and bottom clips in place.
    b) Secure the front & rear safety grills together using the fan grill securing hole in the bottom of the fan grill by inserting the fixing screw and nut provided. c) Push the centre plate onto the front of the grill with the TQ logo level or horizontal.

  4. OPERATION
    Oscillating Control:
    The oscillation pattern can be adjusted from 0-90 degrees. When the adjusting screw is moved towards the rotating axle, the fan will oscillate less of an angle. The longer-the distance from adjusting screw, the larger the oscillating angle will be. Before you change the oscillating angle, disconnect the 240V power supply, then loosen the adjusting screw and adjust to obtain a satisfactory angle.
    Change of the wind direction:
    If you want to change the direction of the air circulation, disconnect the power supply and loosen the direction adjustment bolt to adjust the direction of the fan head to required position and re-tighten the bolt. It is not necessary to move the base of the fan.
    Upward and downward adjustment:
    Disconnect the power, hold the head of fan, loosen the adjustment bolt and stopping bolt, adjust the fan to satisfactory position and tighten up the two bolts. When adjusting the angle of the fan, ensure to keep it within the groove of the lower connection. If you do not follow these instructions, the oscillating function may wear and stop working.
    Head angle adjustment:
    Disconnect the power. Loosen the locking bolt, adjust the fan head to ideal position and then tighten up the locking bolt. In order to avoid the fan head falling down suddenly ensure the fan head is securely held when the locking bolts are being loosened.
    Adjustment of air volume :
    Turn the switch on the back of the fan head to control the operation of the fan to adjust air volume, “1-3” speeds indicate different air volume.

  5. STORAGE
    This Pedestal Fan should always be stored in a dry location on a level surface. When you stop using the fan, you should clean the fan, pack it and put it in dry places, be careful not to damage the fan blade.

  6. MAINTENANCE
    Disconnect power prior to any maintenance Inspect the general condition of the Pedestal Fan checking:
    • for loose hardware
    • cracked, bent, or broken parts, and
    • any other condition that may affect the Pedestal Fan safe operation

  7. SERVICE & REPAIR
    Any Red Label Fan found damaged in any way, or found to be worn or operates abnormally should be removed from service until repaired by an authorised service agent. Owners and/or operators should be aware that repair of this product may require specialised equipment and knowledge. Only authorised parts, labels, and decals shall be used on this equipment. Annual inspection of this Pedestal Fan is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the manufacturer.

PARTS LIST STAND FAN

Part #| Description| QTY| Part #| Description| QTY
---|---|---|---|---|---
1| Centre Plate| 1| 15| Bolt| 1
2| Front Grill| 1| 16| Screw| 1
3| Fan Blade| 1| 17| Flex Support| 1
4| Screw| 1| 18| Fixing Cover| 1
5| Bolt| 4| 19| Fixing Screw| 1
6| Spring Washer| 4| 20| Locking Bolt| 1
7| Washer| 4| 21| Support Column| 1
8| Rear Grill| 1| 22| Separating Cover| 1
9| Motor| 1| 23| Pedestal Base| 1
10| Nut| 1| 24| Gasket| 1
11| Spring Washer| 1| 25| Gasket| 1
12| Washer| 1| 26| Spring Washer| 1
13| Lower Connection| 1| 27| Bolt| 1
14| Wiring Clip| 1| | |

WARRANTY

Red Label products have been carefully tested and inspected before shipment and are guaranteed to be free from defective materials and workmanship for a period of 12 months from Should this piece of equipment develop any fault, please return the complete tool to your nearest authorised warranty repair agent or contact TQB Brands Pty Ltd Warranty team ­ warranty@tqbbrands.com.au.
If upon inspection it is found that the fault occurring is due to defective materials or workmanship, repairs will be carried out free of charge. This guarantee does not apply to normal wear and tear, nor does it cover any damage caused by misuse, careless or unsafe handling, alterations, accident, or repairs attempted or made by any personnel other than the authorised TQB Brands Pty Ltd repair agent. This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised. Your TQB Brands Pty Ltd guarantee is not effective unless you can produce upon request a dated receipt or invoice to verify your proof of purchase within the 12month period.

Consumer Guarantee
Our goods come with a guarantee that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Made in China to TQB Brands Pty Ltd specifications
Visit us at www.tqbbrands.com.au

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals