i Safe MOBILE IS330.2 Cell Phone User Manual

June 6, 2024
i safe MOBILE

i Safe MOBILE IS330.2 Cell Phone User Manual
i Safe MOBILE IS330.2 Cell Phone

INTRODUCTION

This document contains information and safety regulations which are to be observed without fail for safe operation of the device IS330.2 (Model M33A01) under the described conditions. Non-observance of this information and instructions can have serious consequences and / or may violate regulations.

Please read the manual and these safety instructions before using the device. In case of any doubt, the German version shall apply.

The current EU-declaration of conformity, Certificate of Conformity, safety instructions and manuals can be found at www.isafe-mobile.com or requested from i.safe MOBILE GmbH.

RESERVATION

The content of this document is presented as it currently exists. i.safe MOBILE GmbH does not provide any explicit or tacit guarantee for the accuracy or completeness of the content of this document, including, but not restricted to, the tacit guarantee of market suitability or fitness for a specific purpose unless applicable laws or court decisions make liability mandatory. i.safe MOBILE GmbH reserves the right to make changes to this document or to withdraw it any time without prior notice. Changes, errors and misprints may not be used as a basis for any claim for damages. All rights reserved.

i.safe MOBILE GmbH cannot be held responsible for any data or other loss and direct or indirect damages caused by any improper use of this device.

EX-SPECIFICATIONS

The device IS330.2 is suitable for use in potentially explosive atmospheres classified as zones 2/22 in accordance with directives 2014/34/EU and 2014/53/EU, as well as the IECEx scheme.

EX-MARKINGS

  • ATEX:
    • II 3G Ex ic IIC T4 Gc IP64
    • II 3D Ex ic IIIC T135°C Dc IP64
    • Certificate of Conformity:
    • EPS 19 ATEX 1 074 X
    • CE-designation:
  • IECEx:
    • Ex ic IIC T4 Gc IP64
    • Ex ic IIIC T135°C Dc IP64
    • IECEx Certificate: IECEx EPS 19.0037X
  • North America:
    • Class I Div 2 Groups A, B, C, D, T4
    • Class II Div 2 Groups F, G, T135˚C
    • Class III Div 2
  • Temperature range:
    • -20°C … +60°C (EN/IEC 60079-0)
    • -10°C … +50°C (EN/IEC 62368-1)
  • Manufactured by:
    i.safe MOBILE GmbH
    i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany

EU-DECLARATION OF CONFORMITY

The EU-declaration of conformity can be found at the end of this manual.

FCC/IC STATEMENT

The FCC/IC Statement can be found under downloads on the product page of our website: www.isafe-mobile.com/en/products.

FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use and removed from any ex-hazardous areas immediately. Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised, if, for example:

  • Malfunctions occur.
  • The housing of the device shows damage.
  • The device has been subjected to excessive loads.
  • The device has been stored improperly.
  • Markings or labels on the device are illegible.

We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety regulations and has read and understood manual, safety instructions and certificate.

The following safety regulations must also be complied with:

  • Inside ex-hazardous areas the covers of all interfaces (USB, ISM interface) must be closed.
  • To ensure the IP-protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of the housing.
  • The device may only be charged outside ex-hazardous areas. Physical connections to IS330.2 are only allowed outside ex-hazardous areas using equipment approved by i.safe MOBILE GmbH.
  • The IS-HS1.1 or IS-HS1.2 headset or other accessories approved by i.safe MOBILE GmbH may be used within ex-hazardous areas only if connected to the ISM interface.
  • When using IS-HS1.1 or IS-HS1.2 headset or other accessories approved by i.safe MOBILE GmbH , the equipment must be securely fastened to the ISM interface.
  • The device may only be charged at ambient temperatures between +5°C …b +35°C.
  • The device may not be exposed to any aggressive acids or alkalis.
  • The device may only be used in zones 2 or 22.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA

Conditions of Acceptability:

  • The battery may be charged outside explosion hazardous areas only using approved external adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/ DC adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A.
  • The battery may be replaced with an identical one outside of the explosion hazardous areas only.
  • To ensure the IP64 protection, it has to be ensured that all gaskets are present and functional. There must be no gap between the two halves of housing and between the battery cover and housing.
  • The USB interface (type C) located at the left side is for data transmission and it is used in non hazardous areas. It is not permitted to open the USB interface cover in hazardous locations.
  • The ISM interface of the device located at the right side can be used within hazardous areas with approved headsets, Remote Speaker Microphones(RSM) and add-ons.
  • For the ISM interface connection the intrinsically safe approved accessories must comply with entity parameters according to document 1029AD04 i.e. Headset IS HS1.1 and IS-HS1.2 is approved to be used on ISM interface. If the ISM interface is not used, it must be securely closed by the cover provided for this purpose.
  • The device must be protected against excessive UV light emission and high electrostatic processes.
  • The device may only be charged at temperatures between +5°C … +35°C.
FURTHER SAFETY ADVISES
  • Do not touch the screen of the device with sharp objects. Dust particles and nails may scratch the screen. Please maintain the screen clean. Remove dust on the screen with a soft cloth gently, and do not scratch the screen.
  • Do not put the device in environments with excessive temperatures, as this could lead to heating of the battery, resulting in fire or explosion.
  • Do not charge the device near any flammable or explosive substances.
  • Charge the device under indoor conditions only.
  • Do not charge the device in environments with much dust or humidity.
  • Do not use the device in areas where regulations or legislatives prohibit the use.
  • Do not expose the device or charger to strong magnetic fields, such as are emitted from induction ovens or microwaves.
  • Do not attempt to open or repair the device. Improper repair or opening can lead to the destruction of the device, fire or explosion. Only authorized personnel are allowed to repair the device.
  • Power off the device in hospitals or other places where the use of mobile phones is prohibited. This device may affect proper work of medical equipment, such as pacemakers. Always keep a distance of at least 15 cm between the device and these devices.
  • Observe all corresponding laws that are in force in the respective countries regarding the use of devices while operating a vehicle.
  • Please power off the device and disconnect the charging cable before cleaning the device.
  • Do not use any chemical cleaning agents to clean the device or the charger. Use a damp and anti-static soft cloth for cleaning.
  • Do not discard old and abandoned lithium batteries into the trash, send them to designated waste disposal locations.
  • The user alone is responsible for any and all damages and liabilities caused by malware downloaded when using the network or other data-exchange functions of the device. i.safe MOBILE GmbH cannot be held responsible for any of those claims.

WARNING

i.safe MOBILE GmbH will not assume any liability for damages caused by disregarding any of these advices or by any inappropriate use of the device.

MAINTENANCE/REPAIR

Please note any legal requirements for periodic inspection.

The device itself has no user-serviceable parts. It is recommended to perform inspections according to the safety regulations and advises. If there is a problem with the device, please contact your vendor or consult the service center. If your device is in need of repair, you can either contact the service center or your vendor. BATTERY The device may only be charged at ambient temperatures in a range from +5°C … +35°C. INSTALLATION OF THE NANO SIM CARD The device features two nano SIM card slots. These are located in the battery compartment below the battery. WARNING Do only change the SIM card when the device is switched off. Do not try to insert or remove the SIM cards when any external power supply is connected. CELL BROADCAST The device supports cell broadcast. INSTALLATION OF THE microSD CARD The device features a microSD card slot (up to 128 GB). This is located in the battery compartment below the battery. If you want to remove the microSD card, please make sure that the card is not in use by the device. To remove the microSD card follow the instructions given in . WARNING Do only change the microSD card when the device is switched off. Do not try to insert or remove the microSD card when any external power supply is connected, otherwise the microSD card may be damaged.

KEYS AND SPECIAL FEATURES

Product Features

  1. POWER KEY ON/OFF: Long press to power ON/OFF the device. Short press to power ON/OFF the standby mode.
  2. SIDE KEY LEFT: Optional key used by different apps.
  3. LOUDNESS CONTROL: Volume up/Volume down.
  4. USB TYPE C INTERFACE: To charge and to connect the device.
  5. KEYPAD
  6. CUSTOMIZED KEY: Optional key used by different apps.
  7. ISM INTERFACE: See website for approved accessories: www.isafe-mobile.com
  8. FRONT CAMERA
  9. SOS KEY: Long press automatically selects an emergency number stored by you. This function can only be used in conjunction with an optionally available LWP app.
  10. TOUCH SCREEN
  11. EYELET FOR LANYARD: Optional accessory.
  12. BACK CAMERA
  13. FLASH LIGHT
  14. CHARGING CONTACT

RECYCLING

The crossed-out wheeled-bin symbol on your product, battery, literature, or packaging reminds you that all electrical and electronic products, batteries, and accumulators must be taken to separate collection at the end of their working life. This requirement applies in the European Union. Do not dispose of these products as unsorted municipal waste. Always return your used electronic products, batteries, and packaging materials to dedicated collection points. This way you help prevent uncontrolled waste disposal and promote the recycling of materials. More detailed information is available from the product retailer, local waste authorities, national producer responsibility organisations, or your local i.safe MOBILE GmbH representative.

INFORMATION CONCERNING SAR CERTIFICATION

(SPECIFIC ABSORBATION RATE)

Maximum SAR values for this model and the conditions under which these were determined:

  • SAR (head): 0.62 W/kg
  • SAR (body – worn): 0.93 W/kg

This device was tested for typical body-worn operations with the back of the handset kept 5 mm from the body.

TRADEMARKS

  • i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the i.safe MOBILE GmbH.
  • EEA version: Comes with the Google™ app and Google Chrome™ Google and Google Play are trademarks of Google LLC.
  • All other trademarks and copyrights are the properties of their respective owners.

NB WARNING

CAUTION

  • Use careful with the earphone maybe possible excessive sound pressure from earphones and headphones can cause hearing loss.
  • CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
  • Operation temperature: -20°C …+60°C (EN/IEC 60079-0)/ -10°C …+50°C (EN/IEC 62368-1).
  • The device shall only be connected via accessory authorised by i.safe MOBILE GmbH.
  • AC Adapter:
    • Approved external adapter model ICP12-050-2000B (Input: AC100-240V 50/60Hz 0.3A; Output: 5VDC, 2A) or other approved external AC/DC adapter which complies with the requirements of LPS (Limited Power Source) and has output rated 5VDC/2A.
    • Adapter shall be installed near the equipment and shall be easily accessible.
    • The plug is considered independent of the adapter.
  • The device complies with RF specifications when the device used at 0.5 cm from your body. The i.safe MOBILE GmbH hereby declares that this smart phone is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. This information has to be presented in such a way that the user can readily understand it. Typically, this will necessitate translation into every local language (required by national consumer laws) of the markets where the equipment is intended to be sold. Illustrations, pictograms and using international abbreviations for country names may help reduce the need for translation.

MAXIMUM OUTPUT POWER

Frequency bands

|

Maximum output power

---|---
GSM 900| 2W
DCS1800| 1W
WCDMA 900| 24.0dBm
WCDMA 2100| 24.0dBm
LTE Band 1| 23.0dBm
LTE Band 3| 23.0dBm
LTE Band 7| 23.0dBm
LTE Band 8| 23.0dBm
LTE Band 20| 23.0dBm
LTE Band 28| 23.0dBm
LTE Band 38| 23.0dBm
LTE Band 40| 23.0dBm
NFC| -21.815dBu A/m at 10 m
WiFi 2.4G| 17.91dBm EIRP
WiFi 5G| 15.76dBm EIRP
BT| 8.87dBm EIRP
BLE| -0.96dBm EIRP
SRD| 13.80dBm EIRP

GSM ,WCDMA,LTE, BT/BLE,2 4GWIFI/5GWIFI,NFC,GPS,SR.D can be used in Europe without restriction.

Restrictions in the 5 GHz band:

According to Article 10 (10) of Directive 2014/53/EU, the packaging shows that this radio equipment will be subject to some restrictions when placed on the market in Belgium (BE),Bulgaria (BG), the Czech Republic (CZ),Denmark (DK), Germany (DE), Estonia (EE), Ireland (IE), Greece (EL), Spain(ES), France (FR), Croatia (HR), Italy (IT), Cyprus (CY), Latvia (LV), Lithuania(LT), Luxembourg (LU), Hungary (HU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania (RO), Slovenia (SI), Slovakia (SK),Finland (FI), Sweden (SE), the United Kingdom (UK), Turkey (TR), Norway(NO), Switzerland (CH), Iceland (IS), and Liechtenstein (LI).The WLAN function for this device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range.

EU-DECLARATION OF CONFORMITY

EU – Declaration of Conformity

according to directive 2014/34/EU, 2014/53/EU and 2011/65/EU (2015/863/EU)

The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:

Name & address of the manufacturer in the EU| i.safe MOBILE GmbH i_Park Germany
---|---
Description of the devices| Explosion protected mobile phone type / Typ : IS330.2 & IS-HS1.1 model / Modell : M33A01
Ex – marking| II 3G Ex ic IIC T4 Gc IP64 II 3D Ex ic IIIC T135°C Dc IP64
Type examination certificate 2014/34/EU issued by Applied harmonized standards

__

| EPS 19 ATEX 1 074 X Bureau Veritas E&E Product Services GmbH  86842 Tuerkheim, Germany identification number / Kenn-Nummer : 2004
EN IEC 60079-0:2018;  EN 60079-11:2012
Conformity statement 2014/53/EU issued by Applied harmonized standards

| Notified Body
PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg
Germany
identification number / Kenn-Nummer : 0700
EN 62368-1:2014+A11:2017;
EN 50332-1:2013; EN 50360:2017;
EN 50566:2017; EN 62209-1:2016;
EN 62209-2:2010+A1:2019;
EN 62479:2010; EN 50663:2017;
EN IEC 62311:2020;
ETSI EN 301 489-1 V2.2.3;
ETSI EN 301 489-3 V2.1.1;
ETSI EN 301 489-17 V3.2.4;
 | ETSI EN 301 489-19 V2.1.1;
---|---
Draft ETSI EN 301 489-52 V1.1.0;
EN 55032:2015+A11:2020;
EN 55035:2017+A11:2020;
ETSI EN 301 511 V12.5.1;
ETSI EN 301 908-1 V13.1.1;
ETSI EN 301 908-2 V13.1.1;
ETSI EN 300 328 V2.2.2;
ETSI EN 301 893 V2.1.1;
ETSI EN 300 440 V2.2.1;
ETSI EN 300 330 V2.1.1;
ETSI EN 303 413 V1.1.1
Conformity statement 2015/863/EU amending 2011/65/EU issued by Applied harmonized standards| SGS-CsTC Standards Technical Services Co.,
Ltd.
198 Kezhu Road,
Scientech Park Guangzhou Economic &
Technology Development District,
Guangzhou, China 510663
IEC 62321-2: 2013; IEC 62321-1: 2013;
IEC 62321-3-1: 2013; IEC 62321-5: 2013;
IEC 62321-4: 2013 + A1: 2017;
IEC 62321-7-1: 2015;
IEC 62321-7-2: 2017 & ISO 17075-1: 2017;
IEC 62321-6: 2015; IEC 62321-8: 2017
CE Marking| ****

CONTACT/SERVICE CENTER

FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTER:

i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany
service@isafe-mobile.com
www.isafe-mobile.com/service

Document No. 1043MM01REV01
Version: 2021-11-30

Tel. +49 9343/60148-0
info@isafe-mobile.com
www.isafe-mobile.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

i safe MOBILE User Manuals

Related Manuals