AVEO ENGINEERING Morpheus 28 VDC LED Light Installation Guide
- June 6, 2024
- AVEO ENGINEERING
Table of Contents
INSTALLATION MANUAL
Morpheus 28 VDC
Logo LED Light
AVE-LGDC-IM
© Aveo Engineering Group, s.r.o. All rights reserved. The information
contained within this document must not be disclosed, copied, or reproduced in
whole or in part without prior written permission from Aveo Engineering Group,
s.r.o.
Part 0 Document Administration
0.1 Document Approval
This document has been established in accordance with an alternative
procedure to DOA approved under EASA AP429. This installation manual is
applicable for the following part numbers:
MorpheusTM 28 VDC
AVE-LGA1WCNUB-10C
Compiled by:
Petr Jaros Engineer, Aveo Design Group, s.r.o.
31 August 2021
Approved by:
Georg Hartl Head of DO, Aveo Engineering Group, s.r.o.
31 August 2021
0.2 Amendment Record Procedure
The master copy of this document shall be kept electronically as a read-only
document under the control of Aveo Engineering Group, s.r.o. as Master Copy.
ALL amendments to this manual will initiate a raise of issue.
The original issue will be identified by “01”, and subsequent issues will be
numbered sequentially from 02 to 99 in Table 01 – Issue No. column.
ALL issues of this document will be approved by the Head of DO.
Issue No. | Details | Date of issue | Effected Pages |
---|---|---|---|
1 | Initial Issue | 31 Aug 2021 | ALL |
Table 01: Record of Document Amendments
0.3 Effected Pages Procedure
ALL pages affected by ANY raise of issue of this manual will be listed in
Table 01 Affected Pages Column. The reason(s) for EACH raise of the issue and
the description of the respective change will be provided in Table 01 –
Details Column. Changes from the previous issue are shown as follows:
a) new text is highlighted with yellow shading:
b) deleted text is shown with yellow shading and a strikethrough:
Part 1 Installation data
1.1 Product info
The MorpheusTM logo light is a high-powered LED light used in GA and transport
category aircraft. It has been designed to be lightweight and with a low power
draw to meet the highest requirements of all certified aircraft.
MorpheusTM 28 VDC
PN: AVE-LGA1WCNUB-10C
Operating Instructions
When installed on the aircraft, using the aircraft’s power (28 VDC), the light
will be at its maximum intensity. The operating voltage range is 18 36 V DC.
1.3 Installation Schematic / Wiring Diagram
1.4 Control & Power Input
Red (AWG 20) – Power Input 28 VDC
Black (AWG 20) – Power Return Ground
Green/Yellow (AWG 20) – Case
Technical Specification
Environment | Section | Category |
---|---|---|
Temperature / Altitude | 4 | C2 |
Temperature Variation | 5 | A |
Humidity | 6 | C |
Operational Shock and Crash Safety | 7 | B |
Vibration | 8 | R, Curve G |
Explosive Atmosphere | 9 | A |
Waterproofness | 10 | S |
Fluids Susceptibility | 11 | F |
Sand and Dust | 12 | D |
Fungus | 13 | F |
Salt Spray | 14 | S |
Magnetics Effects | 15 | A |
Power Input | 16 | BEX |
Voltage Spike | 17 | A |
Audio Freq. Conducted Susceptibility | 18 | Z |
Induced Signal Susceptibility | 19 | ZX |
Radiated and Conducted Susceptibility | 20 | TT |
Radiated and Conducted Emissions | 21 | H |
Icing | 24 | A |
Technical Drawing
Wiring Chart
Use the diagram below defining the wiring size depending on the current and the wire length. Make sure you add up the current for all connected lights. If the current is not given, then divide the power by the voltage.c
Equipment Limitation
Morpheus™28 VD C should only be powered by 18-36 V DC.
Care and Cleaning of Lights
Aveo Engineering Aviation Lights are factory polished and delivered as ready to install on the aircraft.
If the lights need deeper cleaning, they should be polished with a quality lamb’s wool sheet that is suitable also for deeper polishing. Under no circumstances should any petroleum-based product be used to clean the lights.
Testing of the light before installation
All Aveo Aviation lights undergo rigorous testing prior to being released from
our engineering manufacturing department. This testing involves burn-in time
as well as another functional testing. No light is released for sale without
undergoing this extensive operational testing.
When you receive the Morpheus™28VDC light and wish to test the function of the
light prior to installation on your aircraft, please note the following:
- Please review the written information that is enclosed in the packaging. Warranty information, as well as a cautionary note about power supply removal, is enclosed with each package.
- Remove the light from the package. Note that there are three wires:
RED | 28 VDC |
---|---|
BLACK | Ground |
GREEN/YELLOW | Case |
3. Testing of the function of the light can be done with a regular 18-36 V DC power supply (not a battery charger). Connect the black wire to the ground (negative) leads of a power supply, and then connect the red wire to the positive (+) leads on the power supply. The logo light should start lighting. When installed on the aircraft, using the aircraft’s power (28 V DC), the light will be at its maximum intensity. After testing, the light can be installed on the aircraft.
IMPORTANT NOTES:
- Under no circumstances should any power supply other than an 18-36 V DC be used to test the light. Do not use Battery chargers, battery backup power devices, or other bench avionics testing methods to test the aviation light. The light is functional between 18 and 36 Volts. The use of a battery charger or other power unit to test the light will void the warranty and may damage the light.
If you have any questions about the installation of the lights, please refer to our website: www.aveoengineering.com
Notes on Installation
Spread the tightening forces evenly around the mounting hole. Stainless steel screw is recommended. The length depends upon the placement location of the aircraft.
Continued Airworthiness Information
Circuit/Wiring Protection
Each Morpheus series light features a Negative Temperature Coefficient (NTC)
circuit that limits internal temperatures by attenuating the operating current
(with a corresponding reduction of brightness) when internal temperatures
reach a certain threshold. This proprietary circuitry serves to protect the
light itself, and associated aircraft wiring, against a thermal runaway
condition.
Periodic Inspection Procedure
The Morpheus light is maintenance-free. Periodical checks that the light is
functioning are to be done as required by the aircraft documentation. The
light only contains one LED so the light is either fully operative or not.
The problem of loss in intensity by partially failing LED is therefore not
applicable.
RoHS Compliance Statement
Scope
This statement clarifies Aveo Engineering’s compliance with European Union
Directive 2015/863/EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment (“RoHS”) that took effect on
June 4, 2015. The RoHS Directive restricts the sale of electronic equipment
containing certain hazardous substances in the European Union including:
Cadmium(Cd): 0.01%
Mercury: 0.1%
Lead(Pb) : 0.1%
Hexavalent chromium (Cr6+) : 0.1%
Polybrominated biphenyls (PBB): 0.1 %;
Polybrominated diphenyl ethers (PBDE): 0.1 %
Bis(2-Ethylhexyl) phthalate (DEHP): 0.1% (added in 2015);
Benzyl butyl phthalate (BBP): 0.1% (added in 2015);
Dibutyl phthalate (DBP): 0.1% (added in 2015);
Diisobutyl phthalate (DIBP): 0.1% (added in 2015)
Compliance
Aveo Engineering certifies that all products sourced from manufacturing
facilities comply with the environmental standards set forth by the Directive
2015/863/EU, recast amendment of RoHS Directive 2011/65/EU Article (4), and do
not contain any of the above-mentioned, 10 hazardous substances above the
specified limits. All products manufactured by Aveo Engineering are RoHS-
compliant. With regards to RoHS-2 CE marking, product packaging is labeled
attesting conformity if required.
References
Directive 2015/863/EU of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in electrical and
electronic equipment.
EU REACH Regulation (EC) No. 1907/2006
Aveo Engineering declares that no chemicals are produced and that none of the chemicals used during the production process or needed for the product maintenance or service, is listed on the current European Chemicals Agency’s Candidate List of Substances of Very High Concern for Authorization.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>