nVent H910 WinterGard Splice and Tee Kit Instruction Manual
- June 6, 2024
- nVent
Table of Contents
- nVent H910 WinterGard Splice and Tee Kit Instruction Manual
- APPROVALS
- KIT CONTENTS
- DESCRIPTION
- APPLICATIONS
- TOOLS REQUIRED
- INSTALLATION AND SUPPORT
- HEATING CABLE CONSTRUCTION
- End Seal Installation Instructions for H612 and H622 Heating Cables
- End Seal Installation Instructions for H311, H611 and H621 Heating Cables
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
nVent H910 WinterGard Splice and Tee Kit Instruction Manual
H910
APPROVALS
KIT CONTENTS
DESCRIPTION
The nVent RAYCHEM WinterGard H910 Splice and Tee Kit is for use with WinterGard self-regulating heating cables to make splice, tee, and end seal connections. The kit contains materials for one splice and one end seal, or one tee connection and one end seal. This kit does not provide a power connection; use an nVent RAYCHEM H900 or H908 power connection kit for a complete installation.
APPLICATIONS
Use the H910 kit with the following nVent RAYCHEM WinterGard heating cables: H311, H611, H612, H621, and H622. All are designed for pipe freeze protection in dry locations, but H612 and H622 cables are designed for both wet and dry areas, as well as for roof and gutter de-icing. The cable type is printed on the outer jacket of the cable.
TOOLS REQUIRED
- Diagonal cutters
- Needle nose pliers
- Utility knife
- Heat gun or torch
- Crimp tools (Ideal 30-429 and T&B WT112M or WT2000)
- Hammer and nail (for gutter/downspout applications only)
INSTALLATION AND SUPPORT
The minimum installation temperature for this kit is 0°F (–18°C). See the WinterGard Application and Design Guide (H53585), H900, or H908 installation instructions for design information. For additional technical support call nVent at 800-545-6258.
WARNING:
This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all the installation instructions.
- To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of nVent, agency certifications, and national electrical codes, ground-fault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers.
- Bus wires will short if they contact each other. Keep bus wires separated.
- Keep components and heating cable ends dry before and during installation.
- The black heating cable core is conductive and can short. It must be properly insulated and kept dry.
- Component approvals and performance are based on the use of nVent-specified parts only. Do not use substitute parts or vinyl electrical tape.
- Leave these instructions with end user for reference and future use.
****CAUTION:
HEALTH HAZARD: Overheating heat-shrinkable tubes will produce fumes that may cause irritation. Use adequate ventilation and avoid charring or burning. Consult SDS at nVent.com for further information.
CHEMTREC 24-hour emergency telephone:
800-424-9300
Non-emergency health and safety information:
800-545-6258.
Splice or Tee Connections
The instructions are shown for a tee connection. Splice connections are done the same way, without the third heating cable section.
HEATING CABLE CONSTRUCTION
End Seal Installation Instructions for H612 and H622 Heating Cables
Note: The end seal is designed to be installed only once. It cannot be removed from the heating cable once it is installed. Do not install it until instructed to do so in Step 3
End Seal Installation Instructions for H311, H611 and H621 Heating Cables
Note: The end seal is designed to be installed only once. It cannot be removed from the heating cable once it is installed. Do not install it until instructed to do so in Step 3
North America
Tel +1.800.545.6258
Fax +1.800.527.5703
thermal.info@nVent.com
Europe, Middle East, Africa
Tel +32.16.213.511
Fax +32.16.213.604
thermal.info@nVent.com
Asia Pacific
Tel +86.21.2412.1688
Fax +86.21.5426.3167
cn.thermal.info@nVent.com
Latin America
Tel +1.713.868.4800
Fax +1.713.868.2333
thermal.info@nVent.com
©2020 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>