HAYWARD 110M3 Easy Chem Double pH Rx Metering Pump Owner’s Manual

June 8, 2024
Hayward

HAYWARD-LOGO

HAYWARD 110M3 Easy Chem Double pH Rx Metering Pump

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-
PRODUCT

WARNING: Electrical hazard.
Failure to comply with these instructions can result in serious injuries or death.

THE EQUIPMENT IS INTENDED TO BE USED ONLY IN SWIMMING POOLS

WARNING

  • Carefully read the instructions that appear in this manual and on the device. Failure to comply with the instructions can cause injuries. This document must be given to every pool user, who should keep it in a safe place.
  • Disconnect the equipment from the mains supply before any intervention.
  • All electrical connections must be carried out by a qualified approved electrician in accordance with the standards currently in force in the country of installation or, failing this, in accordance with the international standard IEC 60334-7-702.
  • Check that the device is plugged into a power outlet that is protected against short-circuits. The  device must also be powered via an isolating transformer or a residual current device (RCD) with a nominal operating residual current not exceeding 30 mA.
  • Ensure that children cannot play with the device. Keep your hands and any foreign object away from openings and moving parts.
  • Check that the supply voltage required by the product corresponds to the voltage of the distribution network and that the power supply cables are suitable for the product power supply.
  • Chemicals can cause internal and external burns. To avoid death, serious injury and/or damage to equipment, wear personal protective equipment (gloves, goggles, mask, etc.) when servicing or maintaining this device. This device must be installed in an adequately ventilated place.
  • The unit shall not be operated when there is no water flow in the cell.
  • To reduce the risk of electric shock, do not use an extension cable to connect the device to the mains. Use a wall socket.
  • Use, cleaning or maintenance of the device by children over 8 years of age or by people with impaired physical, sensory or mental capacities, or a lack of experience or expertise, should only take place once they have received appropriate instruction and under adequate supervision of an adult who is responsible for them, to ensure the device is handled safely and avoid all risk of danger.
  • Use only original Hayward® parts.
  • If the power supply cable is damaged, it must be replaced by the manufacturer, the after-sales service or similarly qualified persons to avoid danger.
  • The device must not be used if the power cord is damaged. An electric shock could occur. A damaged power cord must be replaced by the after-sales service or similarly qualified persons to avoid danger.

GENERAL

Before carrying out ANY work inside control panel of the EasyChem Double device, make sure you disconnect it from the power supply. Failure to comply with the instructions contained in this manual could cause injury to people and/or damage to the appliance and the system.

PACK CONTENTS

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(1\)

System

**Item***

| EASY-CH-DPHRXG| EASY-CH-DPHRXGS
---|---|---
A| 2| 1
B| 2| 1
C| 2| 1
D| 2| 2
E| 5| 4
F| 2| 1
G| 2| 1
H| 1| 1
L| 1| 1
M| 1| 1
N| 1| 1
O| 1| 1
P| 1| 1
Q| 1| 1
R| 1| 1
S| 2| 1

NOTE : The values from the table represent the number of items inside the package

INSTALLATION

View of overall installation

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(2\)

  1. Pool
  2. Circulation pump
  3. Acid
  4. Chlorine
  5. Filter
  6. Heat exchanger
  7. pH probe
  8. ORP probe
  9. Temperature sensor

Warning!
Use with salt chlorinator:
For the pH systems, to prevent the risk of system malfunctioning or damage, observe the following instructions:

  1. Position the pH measuring probe prior to the chlorinator cell.
  2. To eliminate eddy currents, connect the pool water to an electrical ground point
  3. Position the product injection point after the chlorinator cell.

Wall-mounted installation
Mount the control box on the wall. The box must be installed in the equipment room (dry, temperate, ventilated). Caution, acid vapours can cause irreversible damage to your device. Position the treatment product tanks accordingly.
Unplug the pool filter pump before you begin the installation. The installation must be performed in compliance with the regulations in effect in the country of installation.

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(3\)

Installation of pH and ORP probes, and acid dosing pump
The pH and ORP probes are «wet» packed and protected by a plastic cap. The probes must always remain wet. If the probes are allowed to dry, they will be permanently unusable (not covered by the warranty) and the pH-ORP test kit will be ineffective. Remove the pH and ORP probes from their plastic protective caps and set the caps aside for later use (wintering). Insert the probes into the double probe holder and tighten to ensure they are watertight. Connect the probe holder to the valves screwed onto the saddle clamps and tighten by hand only. Check that the probes are watertight at startup. Seal with Teflon, if required. After installation, check that the probes are constantly in contact with the water in the pool. When the filtration pump is not running (even for long periods), the water remaining in the chamber may be sufficient to protect the probes.

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(4\)

ELECTRICAL CONNECTIONS

Electrical installation and wiring
Connect the EasyChem Double to a permanent power outlet. Open the peristaltic pump lid (1), unscrew four screws (2) and pull the peristaltic pump on the side (3), as illustrated in the pictures below:

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(5\)

Label connection:

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(6\)HAYWARD 110M3-Easy-Chem-Double-pH
Rx-Metering-Pump-FIG- \(7\)

Electrical suppressor device
It is mandatory to install the coil suppressor, please see the instructions below:

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(8\)

Trigger input by circulation pump

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(9\)

SPECIFICATIONS

Specifications EASY-CH-DPHRXG / EASY-CH-DPHRXGS
Range 0-14pH; -99 -1000mV; 0…+55°C
Accuracy ±0.02pH, ±3mV; ±0.5°C
Device precision ± 0.1 pH; ±10mV; ±1°C
Flow rate pump (l/h) 1.5 l/h
Flow rate pump (SPA model only) 1.5 l/h
Power supply 220-240 VAC 50-60 Hz
Consumption (W) 28 Watt
Probe calibration Automatic
Pump state Pause – Supply
Max. back-pressure 1.5bar
Relay contact (number 3) 250 Vac 10A (resistive load)
Fuse 500 mA (fast)
Weight 3.5 Kg
Dimensions (W–H–D) 212 x 303 x 113 mm

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(10\)

SETUP AND OPERATION

The device is designed to be connected to a protected outlet at all times. The EasyChem Double must not be disconnected unless the pool equipment is undergoing maintenance or the pool is to be closed (wintering).
Assuming that the chemical balance of the water is within the recommended ranges, the device can be started up.

Description of the home screen and defaults parameters

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(11\)

Default parameters

n Item Value
1 Language EN
2 Set Point value 7.4 pH
3 Dosing method Acid (pH)
4 OFA Time OFF
5 Calibration Full
6 Circulation pump ON
7 Dosing type PROP; Relay Aux1, Aux2, Aux3 are disabled
8 IN Freq. OFF
9 Flow Input NO (normally open) (Reed Sensor)
10 Power ON Delay OFF
11 Flow Delay OFF

Measure alarm ranges default parameters

n Item Limits
1 Temp. Measure min + 10°C
2 Temp. Measure Max + 38°C
3 pH Measure     min 6 pH
4 pH Measure    Max 8.0 pH
5 ORP Measure min +450 mV
6 ORP Measure Max +850 mV

To restore the default parameters, follow the steps below:

  • Power off the device unit
  • Keep and pressed and power on the unit
  • The unit will display Init.default
  • Select the unit to reset – WiFi module or dosing system
  • Press or to select Yes or no
  • Select Yes and press to restore the default parameters.

Main menu
Press for 3 seconds to run the main menu and then use and select one of the following functions:

  1. Calibration
  2. Setup
  3. Advanced
  4. Priming

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(15\)

  • Main menu – Press for 3 seconds.
  • At the entry of each menu item, the parameter can be directly modified by using and .
  • Confirmation of the current setting and switching to the next item is done by pressing the button.
  • The menu has a circular structure: once you arrive at the last item, the confirmation of the parameter set by pressing determines the return to the first menu item.

Calibration menu
The Calibration menu consists of three (3) sub-menus:

  • pH : Calibration routine
  • ORP : Calibration routine
  • Temperature : Calibration routine

Note : Please check sections 6f, 6g and 6h for step by step calibration routine.

Setup menu
The Setup menu consists of two (2) sub-menus:

  • pH
  • ORP

Scroll through the menu using , select the item and confirm with .

Setup pH
The Setup pH menu consists of six (6) sub-menus:

  • Setpoint pH: 7.4pH (range 6-8pH) Set the pH value keep in the pool.
  • Setpoint Type: Acid (Acid/Alkaline) Type dosing product to regulate the pH value. Acid: add chemical Acid product, Alka: add chemical Alkaline product.
  • Temperature: 25°C (Automatic compensation by manual value or set Automatic to use an external temperature sensor)
  • OFA Alarm: Over Feed alarm value in minutes value (OFF…60’), it is a maximum relay time activation.
  • Alarm Min: Setting the minimum pH alarm value (0,0…6,0 pH)
  • Alarm Max: Setting the Maximum pH alarm value (8,0…14,0 pH)
  • Time ON: range from 5’’ to 360’’ (Default Time ON: 180’’)
  • Time OFF: range from 5’’ to 360’’ (Default Time OFF: 360’’)

*Notes:
The items Time ON and Time OFF will be displayed if the Timed dosing method is set in the Advanced menu. Time OFF must be equal to or greater than Time ON. Scroll through the menu using , select the item and confirm with .

HAYWARD 110M3-Easy-Chem-Double-pH Rx-Metering-Pump-FIG-
\(18\)

Setup ORP
The Setup ORP menu consists of five (5) sub-menus:

  • Setpoint ORP: 700mV (range 400-850mV) Set the ORP value keep in the pool.
  • Setpoint Type: Low (LOW/HIGH) Type of dosing regulation. Low: add chemical chlorine, High: reduce chemical chlorine.
  • OFA Alarm: Over Feed alarm value in minutes value (OFF…60’), it is a maximum relay time activation.
  • Alarm Min: Setting the minimum ORP alarm value (0…600 mV)
  • Alarm Max: Setting the Maximum ORP alarm value (800…1000 mV)
  • Time ON: range from 5’’ to 360’’ (Default Time ON: 180’’)
  • Time OFF: range from 5’’ to 360’’ (Default Time OFF: 360’’)

Notes : The items Time ON and Time OFF will be displayed if the Timed dosing method is set in the Advanced menu. Time OFF must be equal to or greater than Time ON.

Scroll through the menu using , select the item and confirm with .

Advanced menu
The Advanced menu consists of the following sub-menus:

  • Language: Set language menu (EN, IT, ES, DE, FR)
  • Circulating Pump: Enable/Disable input signal from pool circulation pump High voltage 230Vac.
  • In Freq.: Flow rate function measure, Enable/Disable input frequency signal from water meter pulse sender, set Pulse/Liter or Liter/Pulse.
  • Calib. pH: Double ore Single point and Reference calibration, Double point 7pH and 4pH, Single point 7pH, reference pH value.
  • Calib. ORP: Single point and Reference calibration, Single point 465 mV, reference ORP mV value.
  • Calib. Temp: Reference calibration by external hand held controller.
  • Dosing Type pH: Proportional, Timed, On/Off, Off (disable pump)
  • Dosing Type ORP: Proportional, Timed, On/Off, Off (disable pump)
  • Aux Relay: Set AUX1: pH or disable; AUX2: ORP or Disable
  • Password: Set value to enable password of setting menu. (0000 disable)
  • Reset Cal: Menu to reset the last Calibration value, and reload the factory settings
  • Reset all Param.: Menu to reset all parameter and reload the factorysettings
  • Control Panel: Menu to show the input raw signal, pH in mV raw signal, ORP in mV raw signal, Temperature in Ohm raw signal.
  • Reed: set logic sensor NO/ NC (normally open/close)
  • P.On Delay: Power ON delay function is a countdown timer Off…60’ to delay dosing actions when switch on the device. During this period the system wait the chemical measure stabilizing the dosing pump ar disable.
  • Flow Delay: Flow delay function is a countdown timer Off…60’ to delay dosing actions when the flow rate will be restable, and during this time the chemical measure will be stabilizing the dosing pump are disable.

Scroll through the menu using , select the item and confirm with .

To exit the menu, press ; the instrument will display the question “save?”; confi rm with .
For not saving, select NO using and confirm with .

Priming menu
Priming menu dosing pumps, please select the dosing pump to start the priming action.

View Parameters

Standby system
Press (5 seconds) the system sets in StandBy mode; all functions are disabled

Reset OFA Timer
Press (3 seconds) to reset OFA Alarm or press to reset OFA Alarm.

pH probe calibration
Always begin the calibration procedure with a calibration reset.

Reference calibration

ORP probe calibration
Always begin the calibration procedure with a calibration reset.

Reference calibration

Temperature probe calibration
Always begin the calibration procedure with a calibration reset.

DOSING METHOD

Alarm for the pH/ORP Set Point
When the alarm band is set, a work window is created. If the allowed limits are exceeded the alarm relay closes and remains closed until the measurement is reset or is pressed to deactivate the alarm.

When the OFA time (Over Feed Alarm) is set, the dosing time of Set Point pH/ORP in time is controlled with two alarms:

  • First alarm at 70% of the time set is seen on the display, and the alarm relay closes.
  • Second alarm at 100% of the time set is seen on the display and the alarm relay closes and the pH/ORP pump is blocked.

Press (3 seconds) to reset OFA Alarm or press (5 seconds) to reset OFA Alarm.

ALARMS

*(1 Measure alarm ranges default parameters)**

n Item Limits
1 Temp. Measure min + 10°C
2 Temp. Measure Max + 38°C
3 pH Measure     min 6 pH
4 pH Measure    Max 8.0 pH
5 ORP Measure min +450 mV
6 ORP Measure Max +850 mV

SERVICING

During the fi rst 10-15 days, your system will require more attention:

  • Check that the pH remains at the ideal level (7.2 to 7.4).
  • If the pH is exceptionally unstable and uses a lot of acid, check the alkalinity (see table).

If the balance is highly unstable, contact your pool installer/builder.

  • REMEMBER that the system needs a certain amount of time to adapt to your pool and will require additional chemicals during the fi rst 3-5 days. The pool must be regularly maintained and the skimmer baskets emptied whenever necessary. Also check that your fi lter is not clogged.

  • DOSING PUMPS: Regularly check the acid level to ensure that the pump does not run dry. The dosing pump must be checked and serviced at regular intervals. The Santoprene tube of the peristaltic pump has a lifetime of 2 years. We recommend that you change it once a year.

  • Servicing the probe
    The probe must be clean and free from oil, chemical deposits and contamination to function properly. As it is in continuous contact with the water in the pool, the probe may need to be cleaned weekly or monthly, depending on the number of bathers and other specifi c pool characteristics. A slow response, more frequent pH calibration and inconsistent readings indicate that the probe needs to be cleaned. To clean the probe, turn off the power to the EasyChem Double. Unplug the probe connector from the control box, unscrew the probe and carefully remove it from the chamber. Clean the probe bulb with a soft toothbrush and regular toothpaste. A household washing-up liquid detergent may also be used to remove any oil. Rinse with fresh water, replace the Tefl on tape on the threads, and reinstall the probe. If the probe continues to give inconsistent readings or requires excessive calibration after it has been cleaned, it should be replaced.The lifetime of the probes is 1 year. We recommend that you calibrate them every month during the season the pool is in use.

  • Wintering
    The EasyChem Double, probe and pool piping run the risk of being damaged if the water freezes. In regions that experience long periods of cold weather, be sure to drain all the water from the pump and fi lter and from the supply and return pipes before winter. Do not remove the control box.

  • Probe storage
    The end of the probe must always be in contact with water or a solution of KCl. If it is removed from the measuring chamber, it should be stored in the plastic cap provided (fi lled with water). If the storage cap has been mislaid, the probe should be stored separately in a small glass or plastic container with its end immersed in water. The probe must always be in a frost- free environment.

Hose replacement procedure (valid for 2 and 3 rollers)

Storing the pump after use

  • When the regulation device must be stored, clean water should be pumped through the hose in order to rinse it.
  • Then position the roller at 7h05, turning in the direction indicated by the circular arrow.
  • These two precautions will facilitate the subsequent reactivation of the unit.

TROUBLESHOOTING GUIDE

No display

  • Check that the On / Off switch is on.
  • Check the connection cable between the display and the control box.
  • Check the power supply: 210-230 V ∼ 50 Hz.
  • Check the dosing method if the OFA Alarm show continuously.
  • Check the lifetime probe by calibration method.
  • Check the running pump by Priming function.
  • If the problem persists, contact your pool installer/builder.

ENVIRONMENTAL INFORMATION
Provision regarding professional waste from electrical and electronic equipment (WEEE). In compliance with directive 2012/19/EU regarding the management of waste from electrical and electronic equipment, this pump must be disposed of at a waste sorting site. ==> for more information contact your dealer. Good management of waste from electrical and electronic equipment contributes to the prevention of damage to the environment and human health.

LIMITED WARRANTY

All HAYWARD products are covered for manufacturing defects or material defects for a warranty period of 3 years as of date of purchases. Any warranty claim should be accompanied by evidence of purchase, indicating date of purchase. We would therefore advise you to keep your invoice. The HAYWARD warranty is limited to repair or replacement, as chosen by HAYWARD, of the faulty products, provided that they have been subjected to normal use, in compliance with the guidelines given in their user guides, provided that the products have not been altered in any way, and provided that they have been used exclusively with HAYWARD parts and components. The warranty does not cover damage due to frost and to chemicals. Any other costs (transport, labour, etc.) are excluded from the warranty. HAYWARD may not be held liable for any direct or indirect damage resulting from incorrect installation, incorrect connection,or incorrect operation of a product. In order to claim on a warranty and in order to request repair or replacement of an article, please ask your dealer. No equipment returned to our factory will be accepted without our prior written approval. Wearing parts are not covered by the warranty.

The wearing parts of the salt water chlorinator listed below must be maintained according to their estimated service life:

  • Seal set = 2 years
  • Santoprene tube = 2 years
  • Roller = 2 year

Documents / Resources

| HAYWARD 110M3 Easy Chem Double pH Rx Metering Pump [pdf] Owner's Manual
110M3 Easy Chem Double pH Rx Metering Pump, Easy Chem Double pH Rx Metering Pump, Double pH Rx Metering Pump, Rx Metering Pump, Metering Pump
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals