namron 4512746 Zigbee Dimmer 2-Pol 400w Instruction Manual
- June 6, 2024
- NAMRON
Table of Contents
- NAMRON ZIGBEE DIMMER 2-POL 400W
- Function introduction
- Product Data
- Safety & Warnings
- ZigBee Clusters the device supports are as follows :
- Operation
- 1. Do wiring according to connection diagram correctly.
- 2. This ZigBee device is a wireless receiver that communicates with a
- 3. Zigbee Network Pairing through Coordinator or Hub ( Added to a
- 4. Touch Link to a Zigbee Remote
- 5. Removed from a Zigbee Network through Coordinator or Hub Interface
- 6. Factory Reset Manually
- 7. Factory Reset through a Zigbee Remote (Touch Reset)
- 8. Find and Bind Mode
- 9. Learning to a Zigbee Green Power Switch
- 10. Delete Learning to a Zigbee Green Power Switch
- 11. Setup a Zigbee Network & Add Other Devices to the Network (No
- 12. OTA
- 13. Setting minimum brightness:
- 14. Delete the minimum brightness:
- 15. Set Startup Brightness
- 16. Delete Startup Brightness
- 17. Controlled by a push switch:
- Wiring diagram
- Product Dimension
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
70110004
NAMRON ZIGBEE DIMMER 2-POL 400W
Important: Read All Instructions Prior to Installation
Function introduction
- “Min. Set” Key:
- to set or delete a minimum dimming level
- to set or delete a startup brightness level
- Neutral lead input
- Live lead output
- Neutral lead output
- Live lead input
- “Reset” Key: for network pairing, touchlink, factory reset of the dimmer, turn on/off load
- Switch input
Product Data
Input Voltage
| Output Voltage| Output Current| Allowed Inrush Current| Size( LxWxH)
---|---|---|---|---
100-240VAC| 100-240VAC| 1.8A max| Cold Start 75A max.|
45.5x45x20.3mm
Compatible Load Types
Load Symbol
| Load Type| Maximum Load| Remarks
| Dimmable LED lamps| 200W @ 230V
100W @ 110V|
Due to variety of LED lamp designs, maximum number of LED lamps is further dependent on power factor result when connected to dimmer.
| Dimmable LED drivers| 200W @ 230V
100W @ 110V|
Maximum permitted number of drivers is 200W divided by driver nameplate power rating.
|
Incandescent lighting, HV Halogen lamps
| 400W @ 230V
200W @ 110V|
| Low voltage halogen lighting with electronic transformers| 200W @ 230V
100W @ 110V|
- ZigBee AC phase cut dimmer based on latest ZigBee 3.0 protocol
- 100-240VAC wide input and output voltage
- Supports resistive loads and capacitive loads
- 1 channel output, up to 400W
- input and output with screw terminals, safe and reliable
- Both leading edge version and trailing edge version are available for choosing, default factory setting is trailing edge
- Enables to control ON/OFF and light intensity of connected triac dimmable led light or led driver
- ZigBee end device that supports Touchlink commissioning
- Can directly pair to a compatible ZigBee remote via Touchlink without coordinator
- Supports self-forming zigbee network without coordinator and add other devices to the network
- Supports find and bind mode to bind a ZigBee remote
- Supports zigbee green power and can bind max. 20 zigbee green power switches
- Compatible with universal ZigBee gateway products
- Can be controlled by push switches or momentary switches
- Mini size, easy to be installed into a standard size wall box
- Radio Frequency : 2.4GHz
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
ZigBee Clusters the device supports are as follows :
Input Clusters
- 0x0000: Basic
- 0x0003: Identify
- 0x0004: Groups
- 0x0005: Scenes
- 0x0006: On/off
- 0x0008: Level Control
- 0x0b05: Diagnostics
Output Clusters
- 0x0019: OTA
Operation
1. Do wiring according to connection diagram correctly.
2. This ZigBee device is a wireless receiver that communicates with a
variety of ZigBee compatible systems. This receiver receives and is controlled by wireless radio signals from the compatible ZigBee system.
3. Zigbee Network Pairing through Coordinator or Hub ( Added to a
Zigbee Network)
Step 1: Remove the device from previous zigbee network if it has already
been added to, otherwise pairing will fail. Please refer to the part
“Factory Reset Manually”.
Step 2: From your ZigBee Controller or hub interface, choose to add
lighting device and enter Pairing mode as instructed by the controller.
Step 3: Reset power of the device to set it into network pairing mode (
connected light flashes twice slowly), 15 seconds timeout, repeat this step.
Step 4: Connected light will blink 5 times and then stay solid on, then
the device will appear in your controller’s menu and can be controlled through
controller or hub interface.
4. Touch Link to a Zigbee Remote
Step 1: Method 1: Short press “Reset” button 4 times ( or reset power of
the device 4 times) to start Touchlink commissioning immediately, 180S
timeout, repeat this step.
Method 2: Reset power of the device, Touchlink commissioning will start
after 15S if it’s not added to a zigbee network, 165S timeout. Or start
immediately if it’s already added to a network, 180S timeout. Once timeout,
repeat this step.
Step 2: Bring the remote or touch panel within 10cm of the lighting
device.
Step 3: Set the remote or touch panel into Touchlink commissioning,
please refer to corresponding remote or touch panel manual to learn how.
Step 4: There shall be indication on the remote for successful link and
connected light will flash twice.
Note: 1) Directly TouchLink (both not added to a ZigBee network), each
device can link with 1 remote.
2) TouchLink after both added to a ZigBee network, each device can link
with max. 30 remotes.
3) Tocontrol by both gateway & remote, add remote and device to network
first then TouchLink.
4) After TouchLink, the device can be controlled by the linked remotes.
5. Removed from a Zigbee Network through Coordinator or Hub Interface
- From your ZigBee controller or hub interface, choose to delete or reset the lighting device as instructed. The connected light blinks 3 times to indicate successful reset.
6. Factory Reset Manually
Note: 1) If the device is already at factory default setting, there is no
indication when factory reset again.
2) All configuration parameters will be reset after the device is reset or
removed from the network.
Step 1: Short press “Reset.” key for 5 times continuously or reset power
of the device for 5 times continuously if the “Reset” key is not accessible.
Step 2: Connected light will blink 3 times to indicate successful reset.
7. Factory Reset through a Zigbee Remote (Touch Reset)
Note: Make sure the device already added to a network, the remote added to the same one or not added to any network.
Step 1: Reset power of the device to start TouchLink Commissioning, 180
seconds timeout, repeat this step.
Step 2: Bring the remote or touch panel within 10cm of the lighting
device.
Step 3: Set the remote or touch panel into Touch Reset procedure to reset
the device, please refer to corresponding remote or touch panel manual to
learn how.
Step 4: There shall be indication on the remote and connected light
flashes 3 times for successful reset.
8. Find and Bind Mode
Note: Make sure the device and remote already added to the some zigbee network.
Step 1: Short press “Reset.” button 3 times (Or reset power of the device
(initiator node) 3 times) to start Find and Bind mode (connected light flashes
slowly) to find and bind target node, 180 seconds timeout, repeat this step.
Step 2: Set the remote or touch panel (target node) into find and bind
mode, and enable it to find and bind initiator, please refer to corresponding
remote or touch panel manual.
Step 3: There shall be indication on the remote or touch panel that it
bind the device successfully and can control it then.
9. Learning to a Zigbee Green Power Switch
Step 1: Short press “Reset.” button 4 times (Or reset power of the device
4 times) to start Learning to GP switch mode (connected light flashes twice),
180 seconds timeout, repeat this step.
Step 2: Set the green power switch into Learning mode, please refer to
its manual.
Step 3: Connected light will flash twice to indicate successful learning.
Then the switch can control the device.
Note: Each device can learn to max. 20 zigbee green power switches.
10. Delete Learning to a Zigbee Green Power Switch
Step 1: Short press “Reset.” button 3 times (Or reset power of the device
3 times) to start delete Learning to GP switch mode (connected light flashes
slowly), 180 seconds timeout, repeat this step.
Step 2: Set the paired green power switch into Learning mode, please
refer to its manual.
Step 3: Connected light will flash 4 times to indicate successful
deleting.
11. Setup a Zigbee Network & Add Other Devices to the Network (No
Coordinator Required)
Step 1: Short press “Reset.” button 4 times (Or reset power of the device
4 times) to enable the device to setup a zigbee network (connected light
flashes twice) to discover and add other devices, 180 seconds timeout, repeat
this step.
Step 2: Set another device or remote or touch panel into network pairing
mode and pair to the network, refer to their manuals.
Step 3: Pair more devices and remotes to the network as you would like,
refer to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the
devices can be controlled by the remotes, refer to their manuals.
Note: 1) Each added device can I ink and be controlled by max. 30 added
remotes.
2) Each added remote can I ink and control max. 30 added devices.
12. OTA
The device supports firmware updating through OTA, and will acquire new firmware from zigbee controller or hub every 10 minutes automatically.
13. Setting minimum brightness:
Adjust brightness to a desired level from zigbee hub or controller interface or a remote, then press and hold down “Min. Set ” key until connected light flashes, the minimum dimming level is set successfully, then the connected load can only be dimmable between this minimum brightness and 100% brightness.
The dimming range of this dimmer is 1%-100%, but some load types may flicker when dimmed to 1%, thus a minimum brightness shall be set higher than 1% to avoid flickering during dimming process.
14. Delete the minimum brightness:
Adjust the brightness to 100% from zigbee hub or controller interface or a remote, then press and hold down the Min. Set” key on the dimmer until connected light flashes, which means minimum brightness is deleted successfully
15. Set Startup Brightness
Step 1: adjust the brightness of connected load to a desired level between
1%-50%.
Step 2: double click “Min. set” key to set the brightness adjusted in step 1
as startup brightness, then the load will first go to startup brightness when
turned on every time, then drop down to the brightness before last time turned
off
Note: startup brightness setting function is to avoid the phenomenon that some
dimmable LED drivers can not be turned on after turned of at a very low
brightness level. Once setting a startup brightness, if the startup brightness
is higher than the brightness before turned off, the driver will first go to
the startup brightness after turned on then drop down to the level before
turned off. If the startup brightness is lower than the brightness before
turned off the driver will directly go to the brightness before turned off.
16. Delete Startup Brightness
Step 1: adjust the brightness of connected load to 0%.
Step 2: double click “Min. set” key to delete the previously set startup
brightness.
17. Controlled by a push switch:
Once connected with a push switch, click the push switch to switch ON/OFF, press and hold down it to increase/decrease light intensity.
Wiring diagram
Notes for the diagrams:
L in – terminal for live lead input
N in – terminal for neutral lead input
L out – terminal for live lead output
N out – terminal for neutral lead output
S1 – terminal for switch (has the option of entering the device in
inclusion/exclusion mode)
COM – terminal for grounding to the switch connected to the dimmer
1) With Single Push Switch
With PUSH LV With PUSH
NOTE: Switch connected to the S1 terminal activates the basic functionality of the dimmer (turning the light on/off, dimming).
Note:
-
The max. allowed inrush current of this dimmer is cold start 75A, when connecting LED drivers or LED luminaries in parallel, please make sure that the total inrush current of the parallel connected drivers or luminaries do not exceed the max. allowed inrush current of this dimmer.
-
The recommended number of parallel connected drivers or luminaries shall not be more than 10, otherwise the dimmer may be damaged due to the high inrush current at the moment of starting.
2) With multiple Push switches for multiple control Points
With PUSH LV
With PUSH
Note:
- The max. allowed inrush current of this dimmer is cold start 75A, when connecting LED drivers or LED luminaries in parallel, please make sure that the total inrush current of the parallel connected drivers or luminaries do not exceed the max. allowed inrush current of this dimmer.
- The recommended number of parallel connected drivers or luminaries shall not be more than 10, otherwise the dimmer may be damaged due to the high inrush current at the moment of starting.
This phase dimmer adopts leading edge dimming (forward phase control) or trailing edge dimming (reverse phase control), two versions are available for choosing, default factory setting is trailing edge, leading edge version available upon request. Please make sure the connected loads support the control type you choose. Please refer to the user manual of the load or consult the supplier of the load.
Product Dimension
Importer:
Namron AS
Nedre kalbakkvei 88B
1081 Olso
Norway
Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>