M5-1003 DVI-USB-RS-232 and Audio Optical Extender
User Manual
Welcome!
Congratulations on your purchase of the M5-1003, DVI/USB/RS-232, and audio
optical extender. This manual contains information that will assist you in
installing and operating the product.
Product Description
M5-1003 offers an extremely long extension of DVI, USB, serial control data,
and audio up to 2 km (6,560ft) over single-mode fiber cables with two (2)
duplex LC connectors. It is tremendously long over the limits of copper
extensions like a few meters of DVI and USB.
Designed for high-resolution performance, it guarantees lossless image quality
and no frame dropping to deliver perfect graphic data transmission up to WUXGA
(1920×1200) at a 60Hz refresh rate. It is designed to multiplex and
demultiplex DVI, USB, RS232, and stereo audio so as to be linked over four (4)
single-mode LC fibers at 1310nm/1550nm. It provides a Self-EDID programming
feature that makes the installation of M5-1003 easier and more flexible at any
variable resolution.
Optionally, we could include a convenient remote console switch and indicator
for selecting local control or remote control.
Shipping Group of M5-1003 DVI/USB/Audio and RS-232 optical extender
- Tx and Rx: One Transmitter module & One Receiver module.
- AC/DC power adapter: Two +12V/3A units (including AC cord).
- User Manual
- Bracket: two (2) large size and two (2) small seize brackets
- Option: Remote console switch and indicator
System Requirements for Setup
Hardware requirements
- The local display and remote display should have the same graphic resolution.
- You must have a graphic controller card with a DVI port in your Windows/Mac (Mac is an option), or SUN system. It should support the maximum graphic resolution feature of the display to be connected.
- In the case of using a computer, no special memory size, CPU speed, and chipsets are required.
- A proper initial trial of the entire platform with its application using a short-length copper cable is recommended prior to installation with the optical link.
Software requirements
- No special needs, if the DVI graphic controller and display peripheral are operational with the platform’s OS and application.
AC/DC Power Adapter Technical Advisory
The power of M5-1003 needs to be supplied by plugging the power plugs on each
module (TX and RX) individually.
Installation
Important: Please use the installation procedure below. Improper or no
operation may result if the start-up sequence is not correctly followed.
Step 1
Carefully unpack the contents of the shipping group.
Step 2
With system power turned off, connect the Transmitter to the DVI receptacle of
PC or other video source equipment by a DVI copper cable. If necessary,
connect the RS-232 cable and the audio cable to the D-sub 9-pin connector and
audio jack.
Step 3
Connect the Transmitter to the display, keyboard, and mouse for local control.
You may skip Step 3 if you don’t need local control. In this case, please see
instructions on pages 1-6 for Self-EDID programming.
Step 4
Connect the Receiver module to the remote display, keyboard, and mouse. If
necessary, connect the RS232 cable and the audio cable to the audio output
device and RS-232 device. For proper RS-232 cable type, please refer to Fig
10.
Step 5
Remove dust covers and connect two(2) duplex LC fibers to LC receptacles of
the Transmitter and Receiver modules, as shown in Fig. 5. Ensure the order of
the duplex LC connectors is correct.
Step 6
Connect an AC/DC power adapter to both Transmitter and Receiver modules as
your availability of AC outlets. You can find a power indication LED light on
in both modules.
Step 7
Turn the power of the PC and display. Turn the power of connected USB, audio,
and RS-232 devices too. For proper RS-232 cable type, please refer to Fig 10.
Tip 1: Avoid “hot plugging” the Uplink as this is not recommended with
live digital voltages.
Operation Guide
Selection of Control Position
Graphic data is always transmitted to both local DVI out and remote DVI out. However, the USB port for the keyboard and mouse is selectable for control at a specific position. The controllable site is as shown on the table below with the position of the switch at the front panel of the transmitter.
The position of Switch| Local Keyboard/Mouse(2 USB ports on Tx)|
Remote Keyboard/Mouse (4 USB ports on Rx)
---|---|---
Remote| Disable| Enable
Local| Enable| Disable
Console| Control position is decided by console switch.
Use of Console Switch and Indicator
Console switch and indicators are optionally provided for easy and convenient
control conversion.
Caution
Please DO NOT look directly into the LC receptacles of the Transmitter when it
is powered on. Although this product is regulated strictly enough to operate
under the LASER Class I, classified by CDRH/FDA for eye safety, it is not
recommended to do so.
Self-EDID Programming Procedure
The graphic source equipment generally requires communication of display
information (EDID). Display information (EDID) contains resolution and timing
information for your display. Basically, M5-1003 supports DDC2B with the local
display.
M5-1003 also offers Self-EDID programming. Self-EDID programming means
that the EDID from the display is stored in the transmitter. You should use
Self-EDID feature if you don’t connect the local monitor. Follow these steps
to record the EDID of the display into the transmitter unit.
Note1: If you know that EDID is not required by the source, Auto-EDID
programming is not necessary.
Note2: The default EDID in factory ship-out is programmed in the VESA
standard of UXGA (1600×1200) @60Hz.
Step 1
Power on the display.
Step 2
Insert the included 12V DC power adapter into the transmitter.
Step 3
Push the EDID PRGM. the button of the transmitter with a narrow pin. After
three times blinking of Self-EDID LED, it will stay on.
Step 4
Connect the Local Display port in the transmitter to the display while turning
on over DVI cable. The LED on the front panel will begin to blink rapidly.
Blinking indicates reading the EDID. LED will be turned OFF after blinking for
about 8 sec. The monitor EDID has been recorded.
Step 5
Disconnect the transmitter from the display. Then, LED will turn ON again.
RS-232 Cabling
-
When you connect PC to PC over RS-232 with M5-1003, please use male to female straight type cable between PC and M5-1003-TX and male to male cross type cable between PC to M5-1003-RX.
-
When you connect the PC to the RS-232 device (DUT) over RS-232 with M51003, please use male to female straight type cable between PC and M51003-TX and male to female straight type cable between RS-232 device to M5-1003-RX.
Troubleshooting
The display shows only a black screen.
- Check that all AC and DC plugs and jacks used by external power supplies (both Opticis and others) are firmly connected.
- Ensure that the power LED is ON.
- Ensure that the Transmitter and Receiver modules are connected correctly to the PC and display, respectively.
- Check if the PC and display are powered on and properly booted.
- Reset the M5-1003 using the Reset button on the Uplink and Downlink modules.
- Re-boot up the system after reconnecting the LC optical fibers.
The screen is distorted or displays noises.
- Check if the graphic resolution is properly set. Go to the display properties and tap the settings.
- Reset the M5-1003 using the Reset button on Transmitter and Receiver modules.
- Reset the system.
- Power down, disconnect and reconnect the LC optical fiber or DC power adaptors, and power up.
Maintenance
No special maintenance is required for this product. Ensure that this product
is stored or used in a benign environment free from liquid or dirt
contamination.
There are no user-serviceable parts. Refer all service and repair issues to
Opticis or its authorized distributor.
Technical Support and Service
For commercial or general product support, contact your reseller. For
technical service, contact Opticis by email
techsupp@opticis.com or visit its website at
www.opticis.com.
Product Specifications
M5-1003 Optical KVM Extender
-
Compliance with DVI standard: supports DVI 1.0 of DDWG, using fiber-optic communication links and DDC2B.
-
Compliance with USB 2.0 standard
-
Extension limit:
– up to 2km (6,560ft) over two (2) duplex LC single-mode fibers.
– up to 500m (1,640ft) over two (2) duplex LC multi-mode fibers. -
Audio: 3.5mm analog stereo audio
-
RS-232: D-sub 9 Pin
-
Fiber-optic Connection: The transmitter and receiver boxes of M51003 have two (2) duplex LC receptacles connected to two (2) duplex Single-Mode or Multi-Mode optical patch cords.
Mechanical specifications of Transmitter and Receiver boxes
- Dimensions: 320 x 44 X 130mm (W/H/D)
- Weight: 460 ± 10.0 grams for each of Uplink and Downlink module.
Environmental Specifications
- Operating temperature: 0°C to 50°C
- Storage temperature: – 30°C to 70°C
- Humidity: 10% to 85%
AC/DC Power Adapter
- Power Input: Universal AC 85-264V, 50/60Hz, AC power cord with the power jack.
- Power Output: +12 V, 3.0 A SMPS DC-power Adapter
- Cord DC Jack & length: The core is 12 V and the outer cylinder is GND. The length is 18.5 cm
- AC Cord Length : 1.8m
- Certification: PSE, UL, cUL, FCC, CE, TUV-GS
Warranty Information up
1 (One) Year Warranty
Opticis warrants this Digital Video/Audio and Serial I/O Optical Extender to
be free from defects in workmanship and materials, under normal use and
service, for a period of one (1) year from the date of purchase from Opticis
or its authorized resellers.
If a product does not work as warranted during the applicable warranty period,
Opticis shall, at its option and expense, repair the defective product or
part, deliver to the customer an equivalent product or part to replace the
defective item, or refund to the customer the purchase price paid for the
defective product.
All products that are replaced will become the property of Opticis.
Replacement products may be new or reconditioned.
Any replaced or repaired product or part has a ninety (90) day warranty or the
remainder of the initial warranty period, whichever is longer.
Opticis shall not be responsible for any software, firmware, information, or
memory data of customer contained in, stored on, or integrated with any
products returned to Opticis for repair under warranty or not.
Warranty Limitation and Exclusion
Opticis shall have no further obligation under the foregoing limited warranty
if the product has been damaged due to abuse, misuse, neglect, accident,
unusual physical or electrical stress, unauthorized modifications, tampering,
alterations, or service other than by Opticis or its authorized agents, causes
other than from ordinary use or failure to properly use the product in the
application for which said product is intended.
Dispose of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with separate
systems)
This symbol on the product or on its packaging indicates that this the product
shall not be treated as household waste. Instead, it shall be handed over to
the applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste handling of this
product.
The recycling of materials will help to conserve natural resources. For more
detailed information about recycling this product, please contact your local
city office, your household waste disposal service, or the shop where you
purchased the product.
Certifications
CE / FCC, Class 1 Laser Eye Safety
Certification of Eye Safety
This laser product is inside implemented by using 1310, 1550nm LD
Transceivers, manufactured by Opticis Co., Ltd., are all certified by CDRH/FDA
referred to as classified in Laser Class 1 (IEC60825-1).
Caution – Use of controls or adjustments or performances of procedures other than those specified herein may result in hazardous radiation exposure.
© 2021 Opticis Co., Ltd. All Rights Reserved
Revision 1.7 Feb 2021
Opticis Locations
OPTICIS HQ
Opticis Co., Ltd.
3F, 305, Sanseong-aero
Sujeong-gu, Seongnam-si
Gyeonggi-do, 13354
South Korea
Tel: +82 (31) 719-8033
Fax: +82 (31) 719-8032
www.opticis.com
For order support, please contact your Distributor or Reseller.
For technical support, check with the Opticis website at
www.opticis.com or contact
techsupp@opticis.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>