SEALEY LP40 Space Warmer Propane Heaters Instructions

June 6, 2024
SEALEY

SEALEY LP40 Space Warmer Propane Heaters

Capture
PRO

SAFETY INSTRUCTIONS

PLUG & MAINS POWER SUPPLY

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.

NOTE: 110 volt heaters are usually operated by connecting to a transformer or a generator. Check to
ensure all supply equipment is compatible with the rating of the heater.
The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business  premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.  The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for  the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2 and use a Portable Appliance Tester.  Ensure that cables are always protected against short circuit and overload. . Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
Important: used and that the plug is fitted with the correct fuse – see fuse rating on right.Ensure that the voltage marked on the appliance matches the power supply to be RECOMMENDED FUSE RATING: 3AMP 1.1.7. DO NOT pull or carry the appliance by the power cable.
DO NOT pull the plug from the socket by the cable.
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician. When  an ASTA/BS approved UK 3 pin 13 amp plug or 110 volt plug is damaged, cut the cable just above the plug and dispose of the plug safely. Fit a new plug according to the following instructions (UK only – see diagrams on right).

  •  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
  •  Connect the BROWN live wire to the live terminal ‘L’.
  •  Connect the BLUE neutral wire to the neutral terminal ‘N’.
  •  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm2, but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm2

GENERAL SAFETY

WARNING! Disconnect heater from mains electrical supply and gas cylinder before servicing or performing maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! NOT to be used for the heating of habitable areas of domestic premises: for use in public buildings, refer to national regulations. Store gas cylinders in accordance with regulations applicable to such appliances.

  •  Ensure that nothing stands or passes in front of the heater. Mandatory minimum distance from the heater is 2 metres at the front.
  • Only use the propane gas pressure regulator and hose assembly supplied with the heater, without alteration.
  • Ensure continuous ventilation is provided to the heater operating area. A ventilation opening must run to the outside of the premises where the heater is to be operated. The opening must be 100cm2 for every kW and must also be set at an equal distance from the upper and lower parts of the heater operating area.

WARNING! If the heater is used for prolonged periods at maximum power, ice may form on the propane cylinder. This is due to excessive evaporation. In such a case DO NOT use the heater to de-ice the cylinder.
WARNING! If the smell of gas is present, immediately isolate the gas cylinder and investigate reason before re-connecting it.

  • DO NOT use the heater if damaged. Take immediate action to repair or replace damaged parts. Use an authorised service agent only.
  • DO NOT use the heater for residential use.
  • DO NOT allow untrained persons to ignite the heater.
  • DO NOT operate the heater without the cover.
  • DO NOT exceed the 100W/m3 limit considering the volume of the empty operating location.
  • DO NOT use a naked flame to try and ignite the heater.
  • DO NOT use the heater near inflammable, combustable or explosive materials – liquids, solids or gases.
  • DO NOT leave the heater unattended whilst in use.
  • DO NOT obstruct the air inlet and outlet sections of the heater. Keep immediate area clean and tidy.
  • DO NOT point the heater towards the gas cylinder.
  • Keep children away from the heater.
  • Keep the heater clean and in good working order.
  • Ensure that the heater is correctly turned off and the gas source isolated, when not in use.
  •  When not in use for any length of time, store heater in a safe, dry, childproof location.
    NOTE: This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

SPECIFICATIONS

These propane heaters are fan assisted and fitted with a piezoelectric ignition system for trouble-free starting and feature a direct gas head assembly. Features a safety solenoid preventing the unit from leaking gas without first being electrically started. Front foot offers height adjustment. All models are tested and certified to CE/EN standards by the DVGW test house. Supplied with an approved propane gas regulator and hose. All regulators are Calor approved.Capture FIG 5

INSTALLATION

Note: If a small gas cylinder is used, the heater may not operate at maximum efficiency. It is recommended to use two or more cylinders
linked in parallel, to achieve maximum continuous efficiency (fig.1).
Connections
. Check heater and gas cylinder to ensure that they are both in good condition. If not, stop and contact your supplier immediately. Site the heater and gas cylinder in the location to be heated.
Connect the heater to an electrical supply outlet, ensuring that the machine is correctly earthed. See safety instructions.Connect the gas supply hose to the pressure regulator, and connect the regulator to the gas cylinder (fig.3). Note: Left hand threads. Connect the other end of the gas supply hose to the heater’s gas inlet connector (fig.4). Ensure all connections are tight. Gradually open the tap of the gas cylinder. Check hose and all fittings for gas leaks. Close gas tap if gas is present WARNING! DO NOT USE A NAKED FLAME! To check for leaks, we recommend the use of a foamy soap solution.

 OPERATION

IMPORTANT : To ensure continuous ventilation to the heater area, a ventilation opening must connect to the outside of the premises where the heater is to operate. The opening must be 100cm2 for every kW, and must be set at an equal distance from the upper and lower parts of heater operating area.
Switching Heater On
Turn the On/Off switch to the ‘ON’ position.  Push in and turn the gas control knob (fig.2) counterclockwise to LOW/ position, (HIGH/on Models LP40 and LP40S). This will
light the burner, if it doesn’t repeat once or twice until it lights, then hold the gas control knob in for a further 30 seconds before releasing. 4.1.3. If burner stops when the gas control knob is released, leave the fan on, but wait for one minute before repeating the ignition sequence, again holding the gas control knob in for 30 seconds before releasing.  When the burner is lit, push in and turn the gas control knob counterclockwise to the desired setting (1/2/3), (for all models, except LP40 and LP40S which only have one setting).
Switching Heater Off
Turn the gas control knob (fig.2) fully clockwise to the O position. Allow the fan to continue running until the flame has shut down, then turn the On/Off switch to the ‘OFF’ position. Shut off the gas cylinder tap. Isolate the heater from the electrical supply. When the heater is not in use for any length of time, disconnect it from the electrical and gas supply and store it in a safe, dry, childproof  location.

WARNING! If the flame shuts down during operation, before repeating the ignition sequence, make sure that the fan is not jammed, and the air inlet and outlet are completely free of obstructions. If it is due to overheating, the cause of the problem must be determined and corrected before repeating the ignition procedure.

MAINTENANCE

WARNING! Before commencing service or maintenance, disconnect the heater from the electrical and gas supplies and allow to fully cool. Use authorised parts only. Unauthorised parts may be dangerous and will invalidate the warranty. Should the heater require service or maintenance, a suitably qualified engineer should carry this out or contact your local Sealey service agent. Check the gas supply hose condition regularly, and change if necessary. Carefully clean the fan blade and inside the heater unit with compressed air. Caution: Wear safety goggles to perform this operation. Caution: Wear safety goggles to perform this operation. Check the ignition unit, safety thermostat, and thermocouple condition and ensure that they are clean.

TROUBLESHOOTING

Capture FIG 6

WARNING! Regarding Air Contaminants.

Air contaminants taken into the heater will damage the unit, cause health problems and safety issues.
Example: Body shop filler dust and overspray dust will clog the burner diffuser, contaminate the combustion chamber and damage the internal parts of the heater. If contaminants are present the heater must be supplied with ducted clean air. Please note that any parts damaged by filler dust or overspray dust will not be covered by warranty. Additionally a cleaning charge will be made for any heaters damaged by filler dust or overspray dust.

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment. When the product is no longer required, it must be disposed of in an environmentally protective way.

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.

NOTE : It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY : Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION : For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR 01284 757500 01284 703534 www.sealey.co.uk sales@sealey.co.uk

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SEALEY User Manuals

Related Manuals