LED current selections

The current can be easily configured by choosing the correct combination of the DIP switches (see table below).

ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-02

AVR400 SDIM lumen output table

Current| Power| Luminous flux (4K)| Luminous flux (3K)
AVR400.SDIM, 350mA| 13W| 1600 lm| 1480 lm
AVR400.SDIM, 500mA| 18W| 2260 lm| 2090 lm
AVR400.SDIM, 550mA| 20W| 2450 lm| 2260 lm
AVR400.SDIM, 700mA| 25W| 3010 lm| 2790 lm
AVR400.SDIM, 750mA| 27W| 3200 lm| 2960 lm

Recommended installation heights

ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-02

DIP Switch Settings

ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-04

Detection Area
Sensor sensitivity can be adjusted by selecting the combination on the DIP switches to fit precisely for each specific application. Note: by choosing “Sensor OFF”, it becomes an ordinary driver without occupancy detection.

ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-05

Daylight
Set the level according to the fixture and environment. The light will not turn on if ambient lux level exceeds the daylight threshold preset.
ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-06

Stand-by Dimming Level
The setting is used to select the desired dimmed light level used in periods of absence for enhanced comfort and safety.ENSTO-AVR400-Elektroskandia-
Sweden-AB-Instructio-07

Hold Time
Select the DIP switch conjuration for the light on-time after presence detection. This function is disabled when natural light is sufficient. Note: this function is disabled when the natural daylight exceeds the daylight threshold IV setting for more than 5 minutes.
ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-08

Stand-by Period
This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. Note: “0s” means on/off con-trol; “+∞” means the stand-by period is infinite and the light is effectively controlled by the daylight sensor, off when natural light is sufficient and automatically on at dimming level when insufficient.
ENSTO-AVR400-Elektroskandia-Sweden-AB-Instructio-09

AVR400 SDIM TUTKAVALAISIMEN KYTKENTÄESIMERKKI KOPPLINGSEXEMPEL MED AVR400 SDIM RADAR – ARMATUREN WIRING DIAGRAM OF AVR400 SDIM RADAR LUMINAIRE