VIESSMANN VITODENS 100-W WB1B Regular Gas Boile
Safety, Installation and Warranty Requirements
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliances.
- Do not touch any electrical switches, do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier
WARNING
Improper installation, adjustment, and/ or operation could cause carbon
monoxide poisoning resulting in injury or loss of life.
This product must be installed and serviced by a professional service
technician who is experienced and qualified in hot water boiler installation
and gas combustion.
Safety, Installation and Warranty Requirements
Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections).
- Product documentation Read all applicable documentation before commencing installation. Store documentation near boiler in a readily accessible location for reference in the future by service personnel.
- For a listing of applicable literature, please see section entitled “Important Regulatory and Safety Requirements”.
|
---|---
- Warranty Information contained in this and related product documentation must be read and followed. Failure to do so renders the warranty null and void.
|
- Licensed professional heating contractor The installation, adjustment, service and maintenance of this equipment must be performed by a licensed professional heating contractor.
- Please see section entitled “Important Regulatory and Installation Requirements”
|
- Contaminated air Air contaminated by chemicals can cause by-products in the combustion process, which are poisonous to inhabitants and destructive to Viessmann equipment.
- For a listing of chemicals which cannot be stored in or near the boiler room, please see subsection entitled “Combustion Air Supply”.
|
- Advice to owner Once the installation work is complete, the heating contractor must familiarize the system operator/ ultimate owner with all equipment, as well as safety precautions/requirements, shutdown procedure, and the need for professional service annually before the heating season begins.
|
- Carbon monoxide Improper installation, adjustment, service and/or maintenance can cause flue products to flow into living space. Flue products contain poisonous carbon monoxide gas.
- For information pertaining to the proper installation, adjustment, service and maintenance of this equipment to avoid formation of carbon monoxide, please see instructions supplied with burner.
|
- Fresh air This equipment requires fresh air for safe operation and must be installed ensuring provisions for adequate combustion and ventilation air exist.
- For information pertaining to the fresh air requirements of this product, please see subsection entitled “Combustion Air Supply”.
|
- Equipment venting Never operate boiler without an installed venting system. An improper venting system can cause carbon monoxide poisoning.
- For information pertaining to venting and chimney requirements, please see section entitled “Venting Connection”. All products of combustion must be safely vented to the outdoors.
|
WARNING
Installers must follow local regulations with respect to installation of carbon monoxide detectors. Follow manufacturer’s maintenance schedule of the boiler contained in “Service Instructions” manual.
**** About these Instructions
Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include “WARNING”, “CAUTION”, and “IMPORTANT”. See below.
WARNING
Indicates an imminently hazardous situation which, if not avoided, may result in minor injury or product/ property damage.
- Warnings draw your attention to the presence of potential hazards or important product information.
** WARNING**
Indicates an imminently hazardous situation which, if not avoided, may result in minor injury or product/ property damage.
- Cautions draw your attention to the presence of potential hazards or important product information
IMPORTANT
-
Helpful hints for installation, operation or maintenance which pertain to the product.
-
This symbol indicates that additional, pertinent information is to be found.
-
This symbol indicates that other instructions must be referenced.
For your Safety
-
Operation
Before operating the boiler, make sure you fully understand its method of operation. Your heating contractor should always perform the initial start-up and explain the system. Any warranty is null and void if these instructions are not followed. -
Flue gas smell
– Deactivate heating equipment.
– Open windows and doors.
– Inform your heating contractor immediately. -
Working on the equipment
All personnel working on the equipment or the heating system must have the proper qualifications and hold all necessary licenses. Ensure main power to equipment, heating system, and all external controls have been deactivated. Close main gas supply valve. Take precautions in all instances to avoid accidental activation of power during service work. -
Dangerous conditions
– Deactivate main power immediately.
– Close gas supply valve. -
Maintenance and cleaning
Regular inspection and service by a qualified heating contractor is important to the performance of the Viessmann Vitodens 100-W. Neglected maintenance impacts on warranty; regular inspection ensures clean, environmentally friendly and efficient operation. We recommend a maintenance contract with a qualified heating contractor. -
Technical information
– Technical Data Manual
– Installation and Service Instructions
– Operating Instructions and User’s Information Manual
– Vitodens Venting System Installation Instructions
– Quick Start-up Guide
– Instructions of other products utilized and installed
– Installation codes mentioned in this manual -
Carbon monoxide The U.S. Consumer Product Safety Commission strongly recommends the installation of carbon monoxide detectors in buildings in which gas-burningequipment is installed. Carbon monoxide (CO) is a colorless, odorless gas, which may be produced during incomplete combustion of fuel and/or when the flame does not receive an adequate supply of combustion air. Carbon monoxide can cause severe personal injury orloss of life. Therefore, carbon monoxide detectors that are in compliance with a nationally recognized standard (e.g. ANSI/UL 2034-2002, CSA 6.19-01) should be installed and maintained in buildings that contain gas-burning equipment.
Note: Viessmann does not test any detectors and makes no representation regarding any brand or type of detector. -
For safe operation
We recommend that you frequently:
– Check for debris which could obstruct the flow of flue gases. The vent or chimney must not be blocked. A blocked or partially blocked vent or chimney can cause flue gases to leak into the structure. Fluegases leaking into the house can cause injury or death. A qualified heating contractor must remove the blockage from blocked or partially blocked chimneys.
– Check pressure gage for correct system (water) pressure. Check for water on the floor from the discharge pipe of the pressure relief valve or any other pipe, pipe joint, valve or air vent.
– Check for moisture, water, or appearance of rust on the flue gas pipes, their joints as well as vent dampers, or side wall vent terminals (if so equipped).
– Ensure that nothing is obstructing the flow of combustion and ventilation air and no chemicals, garbage, gasoline, combustible materials, flammable vapors and liquids are stored (not even temporarily) in the vicinity of the boiler.
– Do no t allow unsupervised children near the boiler.Service/inspection of the boiler and the system is recommended once per year. Maintenance, service and cleaning are specified in the Installation and Service Instructions. Before the heating season begins, it is recommended that the boiler and burner be serviced by a qualified heating contractor. Service contracts may be established through gas suppliers or other licensed contractors in your area.
** WARNING**
As there are no user-serviceable parts on the boiler, burner or control, the
end-user must not perform service activities or adjustments of any kind on
system components. Failure to heed this warning can cause property damage,
severe personal injury, or loss of life.
** WARNING**
Improper installation, adjustment, service, or maintenance can cause flue
products to flow into living space. Flue products contain poisonous carbon
monoxide gas which can cause nausea or asphyxiation resulting in severe
personal injury or loss of life
** CAUTION**
Should overheating occur or the gas supply fail to shut off, do not disconnect
the electrical supply to the pump. Instead, shut off the gas supply at a
location external to the appliance.
WARNING
The operator/ultimate owner is required to have the heating boiler, burners,
and controls checked, as a minimum once per year, by the original installer or
by a competent heating contractor familiar with the equipment. Defects must be
corrected immediately.
** CAUTION**
Do not use this boiler if any part has been under water. Immediately call a qualified heating contractor to inspect the boiler and to replace any part of the control system and any gas control which has been under water.
Frozen water pipe hazard
** CAUTION**
Failure to protect against frozen pipes could result in burst water pipes, serious property damage and/or personal injury. Boiler may shut down. Do not leave your home unattended for long periods of time during freezing weather conditions without turning off the water supply and draining water pipes or otherwise protecting against the risk of frozen pipes
Your heating boiler is designed to provide a warm and comfortable living
environment. It is NOT designed to ensure against freezing of water pipes. The
boiler is equipped with several safety devices that are designed to shut down
the boiler and to prevent it from restarting in the event of various unsafe
conditions. If your boiler remains off for an extended period of time during
cold weather, water pipes may freeze and burst, resulting in extensive water
damage and conditions in which mold could grow. Certain molds are known to
cause respiratory problems, as well as to pose other serious health risks. In
case of water damage, immediate measures should be taken to dry out affected
areas as quickly as possible to prevent mold from developing.
If your home will be unattended for an extended period
of time during cold weather, you should…
– Shut off the water supply to the building, drain the water pipes and add
an antifreeze for potable water to drain traps and toilet tanks. Open faucets
where appropriate. Or…
– Have someone check the building frequently during cold weather and call a
qualified service agency if required. Or…
– Install a reliable remote temperature sensor that will notify somebody of
freezing conditions within the home.
** WARNING**
If you notice fire coming from the appliance, call the fire department
immediately! Do not attempt to extinguish the fire unless qualified to do so.
** WARNING**
Fire causes a risk of burns and explosion!
-
Shut down the boiler
-
Close fuel shut-off valves
-
Use a tested fire extinguisher, class ABC.
-
Ensure ambient temperatures are higher than 32° F (0° C) and lower than 104° F (40° C).Prevent the air from becoming contaminated by halogenated hydrocarbons (e.g. as contained in paint solvents or cleaning fluids) and excessive dust (e.g. through grinding or polishing work). Combustion air for the heating process, and ventilation of the boiler room must be free of corrosive contaminants. To that end, any boiler must be installed in an area that has no chemical exposure. The list to the right indicates the main, currently known sources.
-
Avoid continuously high levels of humidity (e.g. through frequent drying of laundry).
-
Never close existing ventilation openings.
Replacement components, spare and wear parts
IMPORTANT Components which are not tested with the heating system
may damage the heating system, or affect itsfunctions. Installation or
replacement may only be carried out by a qualified heating contractor.
** WARNING**
Incorrect ambient conditions can lead to damage to the heating system and put safe operation at risk
Sources of combustion and ventilation air contaminants.
Areas likely to contain contaminants:
– New building construction
– Swimming pools
– Remodelling areas, hobby rooms
– Garages with workshops
– Furniture refinishing areas
– Dry cleaning/laundry areas and establishments
– Auto body shops
– Refrigeration repair shops
– Metal fabrication plants
– Plastic manufacturing plants
– Photo processing
Products containing contaminants:
– Chlorine-type bleaches, detergents and cleaning
solvents found in household laundry rooms
– Paint and varnish removers
– Hydrochloric acid, muriatic acid
– Chlorine-based swimming pool chemicals
– Spray cans containing chlorofluorocarbons
– Chlorinated waxes and cleaners
– Cements and glues
– Refrigerant leaks
– Calcium chloride used for thawing
– Sodium chloride used for water softening salt
– Permanent wave solutions
– Adhesives used to fasten building products and other similar items
– Antistatic fabric softeners used in clothes dryers
Overview of Controls and Indicators
Controls and indicators are located behind the hinged front cover. Flip up the front cover to access the controls.
Legend
A Pressure gage
B LCD display
C “ ” Water temperature, rotary selector (when used with optional
CombiPLUS kit only)
D “ ” Selector dial for boiler water temp.
E ON / OFF switch
F Gas shut-off valve
Legend
A Heating mode pump output on
B Pump output on (when DHW contact is closed or when the optional
CombiPLUS kit is used))
C Boiler water temperature in °F or fault code
D Units for boiler water temperature measurement
E Service mode
F Current burner firing rate
G Burner in operation
H Fault
I Comfort function started
J Comfort function stopped
Your Vitodens 100 Boiler
Please ask your heating contractor to check off the appropriate box ( ).
- Vitodens 100 without domestic hot water tank The control unit activates and deactivates space heating and supplies rooms with heat.
- Vitodens 100 with separate domestic hot water tank Domestic hot water heating has priority over space heating. The control unit switches automatically to space heating when the preset domestic hot water temperature is reached.
- Vitodens 100 with optional CombiPLUS for instantaneous DHW heating Domestic hot water heating has priority over space heating. The control unit switches automatically to space heating when the heat exchanger temperature is satisfied (with comfort switch on) or when the preset domestic hot water temperature is reached (with comfort switch off).
Changing Room Temperature
In case a separate external room temperature controller (thermostat) is installed, the desired room temperature will be adjusted using this device. Make adjustments using the appropriate operating instructions only. Note: lf thermostatic radiator valves are installed in the room where the control is installed they must be fully open. In case the room temperature setting on the separate room temperature controller is not sufficient to achieve the desired room temperature (e.g. during a particularly cold winter), the boiler water temperature can be adjusted accordingly using the boiler water temperature selector dial “ ”.
Heating System Operation
Switching ON
Room dependent control:
Outdoor temperature sensor not connected With no outdoor sensor
installed, the “ ” dial will provide a constant temperature set-point for the
boiler based on the dial position selected. Setting the dial between 1 and 6
will provide a set-point value of 81º F to 178º F (27º C to 81º C)
respectively. The dot between 4 and 5 represents the factory default set-point
value of 140º F (60º C).
Weather dependent control Outdoor temperature sensor connected
With the outdoor sensor connected, the boiler will automatically recognize the
sensor and switch the setpoint dial operation from constant temperature
calculated to outdoor reset calculated. Adjusting the “ ” dial will select the
heating curve corresponding with the heating curve chart. The setpoint will
becalculated from the design boiler water temperature associated with the
heating curve selected, and reset from the actual outdoor air temperature.
Setting the dial between 1 and 6 will select the corresponding curve from the
chart. The dot between 4 and 5 is the factory default curve. The display “ ”
indicates when a heat request hasbeen made.
Note: Both the room dependent control and the outdoor reset control
strategies require a closed contact at terminals RT to generate a call for
heat to the boiler. Setting the dial to “ ” places the boiler in freeze
protection mode regardless of the control option selected or the contact
position at RT.
Switching OFF
Turn the selector dial “tr” to “ ”.
Note: If an external OpenTherm device is connected that controls the boiler
water temperature, it can no longer be adjusted using the selector dial “ ”
Legend
A Selector dial “tr” setting: 1
B Selector dial “tr” setting: 2
C Selector dial “tr” setting: 3
D Selector dial “tr” setting: 4
E Factory default
F Selector dial “tr” setting: 5
G Selector dial “tr” setting: 6
Domestic Hot Water
Select the DHW temperature in accordance with your requirements (e.g. for showering).
When used with the CombiPLUS, the numbers represent an approximate temperature
setting of:
0 No DHW
1 95º F (35º C)
2 105º F (40º C)
3 110º F (43º C)
4 120º F (49º C)
5 125º F (52º C)
6 135º F to 140º F (57º C to 60º C)
With CombiPLUS kit only
Switching ON
Move rotary selector “ “ to the required DHW temperature.
If DHW heating is active, the indicator “ “ appears on the display.
Switching OFF
Turn rotary selector “ “ to “0”.
Note: If the boiler is not used with the CombiPLUS kit, turn the rotary
selector “ “ 0 “”. When in operation with a separate Domestic Hot Water (DHW)
tank, the domestic hot water temperature is adjusted at the temperature
control of the DHW tank. When heating a domestic hot water tank, external heat
demand or used with the CombiPLUS kit, the display shows “ ”. The boiler water
temperature is automatically adjusted to satisfy the DHW demand.
The scalding label is placed on the front of the boiler.
Note: This label must be installed as required by national code.
Comfort Function
If the comfort function is switched ON (when used with the DHW CombiPLUS Kit only), the instantaneous water heater is kept up to temperature (standby). Hot water is therefore quickly available.
Starting the comfort function
Briefly turn selector “ “ clockwise as far as possible, wait for SERV to appear momentarily (for less than 3 sec.) then turn it counter clockwise again. “COMFORT” appears on the display.
Stopping the comfort function
Briefly turn the rotary selector “ “ counter clockwise as far as possible, wait for SERV to appear momentarily (for less than 3 sec.) then turn it clockwise again. “ECO” appears on the display.
Heating Water Temperature and System Pressure
Checking the boiler heating water temperature
During operation, the heating water temperature is constantly displayed.
Checking the system pressure
Check the pressure of your heating system on the pressure gage. Minimum
system pressure must be 0.8 bar (12 psi).Notify your heating contractor if the
pressure of the system is too low.
Switching OFF Vitodens with Frost Protection
Switch OFF the equipment if you do not wish to use your
heating system for a few days.
Turn selector dial ” ” to “0”.
Boiler frost protection is active.
Frost protection
Frost protection is continuously active. The burner is switched ON when the
boiler water temperature reaches 41° F (5° C) and is switched OFF again when
the boiler water temperature reaches at least 59° F (15° C) but not more than
68° F (20° C).
Shutting Down the Heating System
Shut down your heating system completely, if it is not needed for longer periods of time (several months). Before you switch your heating system OFF for longer\ periods, it is advisable to contact your local heating contractor. Your heating professional will take any necessary measures, e.g. for freeze protection of the system or to protect the heat emitter surfaces, e.g. radiators etc.
- Close gas shutoff valve and secure against unintentional opening.
- Switch OFF line voltage (e.g. at separate fuse/circuit breaker).
The power supply to the system is now switched off.
IMPORTANT
At this point the boiler and the system are no longer protected from freezing.
Fault Diagnosis and Correction
Issue | Cause | Corrective Action |
---|---|---|
Heating system does not start up | Heating system switch turned to OFF on | |
control unit | Turn switch to ON on control unit. | |
Selector dial “ ” is set to “0”. | Set required heating water temperature (see |
page 10).
Circuit breaker or fuse in power supply or in boiler control unit has blown or
tripped| Inform heating contractor.
Burner does not switch on or only intermittently| No gas| Open gas shut-off
valve or contact your gas supply company.
Fault on control unit| Make a note of the fault code and inform heating
contractor.
Burner does not start up; burner fault, “ ” is displayed on control unit|
Faulty start-up| Press ON / OFF switch to OFF position and then back ON. This
will reset the boiler fault (see page 10). Should this attempt fail, contact
your heating contractor.
Fault on control unit
Burner does not start up, no fault “ “ display. “ ” and / or ” “ on the
display| No water flow| Flow switch defective or boiler pump failure. Inform
heating contractor.
Burner does not start up; burner fault “ ” appears in display| Power supply
too low| Contact your Hydro company.
The burner switches off even though the desired room temperature has not been
reached| Fault in combustion air supply or in the venting system| Contact your
heating contractor.
Heating water temperature or room temperature is set too low| Increase heating
water temperature by turning selector dial “ ” or by increasing desired room
temperature on the room thermostat.
Air in heating system
Rooms are cold although burner is operating| Domestic hot water supply has
priority (operation with DHW storage tank only)| Wait until the domestic hot
water heating is complete.
Fault on programmable room thermostat| Contact your heating contractor.
Circulation pump fault
Rooms are not at the required temperature, even though the temperature is
operating| DHW priority|
Circulation pump faulty
DHW temperature is too low| DHW temperature is set too low or rotary selector
“ “ is set to “0” (only with the CombiPLUS kit)|
Fault code “58” appears on the display| Jumper connection shorted out, removed
or missing| Contact your heating contractor.
Service Instructions for Your Heating System
Any faults in your heating system are indicated on the display by a flashing fault symbol ” ”. Read off the fault code in the display and report it to yourheating contractor. This helps the contractor to properly prepare, and may result in lower service costs.
WARNING
Visually inspect the vent termination for any signs of blockage. Under cold climate conditions [sustained temperatures below 0° F (-18° C)] the vent termination may be severely blocked by icicle and frost build-up. The boiler control will automatically shut down the boiler should air intake or vent be blocked. Remove blockage if possible. Reset the boiler switch (ON / OFF switch to OFF and then back to ON) (see page 10) and the boiler should attempt to restart. If blockage is not obvious and cannot be removed, contact a licensed professional heating contractor.
Service Instructions for your Heating System
Viessmann strongly recommends inspection/service of the boiler and the system
by a licensed professional heating contractor once per year.
Before the heating season begins, the boiler with its burner(s) and vent
system should be serviced by a qualified heating contractor. Service contracts
may be established through gas suppliers or other licensed contractors in your
area.
Regular inspection/service ensures trouble free, energy-efficient and
environmentally friendly heating activity of your heating system
Viessmann domestic hot water storage tank
Inspection and (if necessary) cleaning of the tank must take place within 2
years of initial start-up and every 2 years thereafter.
Cleaning of the inside surfaces of the domestic hot water storage tank,
including domestic hot water connections, may only be performed by a licensed
professional heating contractor.
Vitocell 100:
Viessmann recommends an annual inspection, and replacement if required, of the
consumable anode by a licensed professional heating contractor. The inspection
can be carried out during regular operation of the heating system; shut-down
is not required.
The heating contractor measures the protective current with an anode testing instrument.
Drinking water filter (if installed)
For hygienic reasons:
– replace filter element every 6 months on filters which cannot be flushed
back, and perform a visual inspection every 2 months,
– flush back reversible flow filters every 2 months.
Notes on operation:
– Ensure boiler room and boiler are clean.
– Regularly check heating system pressure on the pressure gage:, If the system
operating pressure gage is indicating a pressure of below 14 psig, the system
pressure is too low; in this case, please contact your heating contractor.
IMPORTANT
If a water treatment device (water softener) is installed in the domestic cold
water supply to the hot water storage tank, ensure its proper working
condition is checked regularly by your heating contractor.
The same applies if a dirt trap or a water filter is installed in the domestic
cold water supply. Any of these devices installed in the domestic cold water
supply must be flushed out and serviced on a regular basis.
Please follow the manufacturer’s instructions.
How to Save Energy
… with regular maintenance
Regular maintenance check-ups of your heating system ⑥ by a licensed
professional heating contractor will ensure energy savings and environmentally
friendly operation.
…. with effective insulation
If you wish to make use of additional energy-saving measures, check the
thermal insulation:
– of heating and domestic hot water pipes.
– of external walls and the roof.
– between heated and unheated rooms.
– of the windows.
…. by heating the right way
Apart from taking advantage of the benefits of a modern heating system,
there is a lot you can do yourself to achieve additional fuel savings.
For instance:
– Don’t overheat:
Aim at a room temperature of 68º F (20º C).
Every 2º F (1º C) less in room temperature will reduce your heating bills by
up to 6%.
– Close window shutters (if installed) at dusk.
– Operate thermostatic valves ② correctly.
– Don’t obstruct radiators ③ and thermostatic valves ②.
– Make use of individual adjustment options of the control unit ④ (supplied by
others); e.g. “normal room temperature” alternating with “reduced room
temperature”.
– Set the domestic hot water temperature of the DHW tank ⑤ on the control unit
of the tank or on external controller.
– Control your consumption of hot water:
A shower generally consumes less energy than a bath.
Lighting and Operating Instructions
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. Do not try to light the burner
by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure
to smell next to the floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
-
STOP! Read the safety information above on this label.
-
Set thermostat or other operating control to lowest setting.
-
Turn off all electric power to the appliance.
-
This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
-
Close main gas shut-off valve.
-
Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.
-
Open main gas shut-off valve.
-
Turn on all electric power to the appliance.
-
Set thermostat or other operating control to desired setting.
-
If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
- Set thermostat or other operating control to lowest setting.
- Turn off all electric power to the appliance if service is to be performed.
- Close main gas shut-off valve.
Viessmann Manufacturing Company Inc.
750 McMurray Road
Waterloo, Ontario• N2V 2G5 • Canada
Techlnfo Line 1-888-484-8643
1-800-387-7373 • Fax (519) 885-0887
www.viessmann.ca •
info@viessmann.ca
Viessmann Manufacturing Company {U.S.) Inc.
45 Access Road
Warwick, Rhode Island • 02886 • USA
Techlnfo Line 1-888-484-8643
1-800-288–0667 • Fax (401) 732–0590
www.viessmann-us.com • info@viessmann-
us.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>